Abstract Background: Timely diagnosis of periodontal disease is crucial for restoring healthy periodontal tissue and improving patients’ prognosis. There is a growing interest in using salivary biomarkers as a noninvasive screening tool for periodontal disease. This study aimed to investigate the diagnostic efficacy of two salivary biomarkers, lactate dehydrogenase (LDH) and total protein, for periodontal disease by assessing their sensitivity in relation to clinical periodontal parameters. Furthermore, the study aimed to explore the impact of systemic disease, age, and sex on the accuracy of these biomarkers in the diagnosis of periodontal health. Materials and methods: A total of 145 participants were categorized into three groups based on their basic periodontal examination index, with 20 in the periodontally healthy group, 50 in the gingivitis group, and 75 in the periodontitis group. Salivary LDH was measured using the rate of nicotinamide adenine dinucleotide (NADH) oxidation, to measure the kinetics of LDH activity, while total protein was measured using the Lowry method. Descriptive and analytical statistical analyses were performed to examine the associations between the variables and biomarkers. Results: The results of the study demonstrated that salivary LDH was 72% sensitive, while salivary total protein was 78% sensitive in correlation to clinical periodontal parameters. The accuracy of the test was not influenced by sex, but age had a significant effect on both biomarkers, particularly LDH. Systemic disease was another factor that significantly affected the accuracy of the test. Conclusions: Although salivary LDH and total protein show promise as biomarkers for screening periodontal disease, their interpretation may be impacted by age and systemic disease.
This study includes the preparation of the ferrite nanoparticles CuxCe0.3-XNi0.7Fe2O4 (where: x = 0, 0.05, 0.1, 0.15, 0.2, 0.25, 0.3) using the sol-gel (auto combustion) method, and citric acid was used as a fuel for combustion. The results of the tests conducted by X-ray diffraction (XRD), emitting-field scanning electron microscopy (FE-SEM), energy-dispersive X-ray analyzer (EDX), and Vibration Sample Magnetic Device (VSM) showed that the compound has a face-centered cubic structure, and the lattice constant is increased with increasing Cu ion. On the other hand, the compound has apparent porosity and spherical particles, and t
... Show MoreSoil is a crucial component of environment. Total soil analysis may give information about possible enrichment of the soil with heavy metals. Heavy metals, potentially contaminate soils, may have been dumped on the ground. The concentrations of soil heavy metals (Cd, As, Pb, Cr, Ni, Zn and Cu) were measured in three zones thought to be deeply contaminated at different depths (5, 25, 50 cm) at Ibn Al-Haitham College. The highest concentration of heavy metals Pb (63.3ppm), Cr (90.7ppm), Ni (124ppm) and Cu (75.7ppm) were found in zone (A) location-1, where the highest concentration of Zn (111.7ppm) was found in zone (C). Cd and As were detected in small amounts in all zones. PH value, organic matters, carbonat
... Show More