This paper presents an alternative method for developing effective embedded optimized Runge-Kutta (RK) algorithms to solve oscillatory problems numerically. The embedded scheme approach has algebraic orders of 5 and 4. By transforming second-order ordinary differential equations (ODEs) into their first-order counterpart, the suggested approach solves first-order ODEs. The amplification error, phase-lag, and first derivative of the phase-lag are all nil in the embedded pair. The alternative method’s absolute stability is demonstrated. The numerical tests are conducted to demonstrate the effectiveness of the developed approach in comparison to other RK approaches. The alternative approach outperforms the current RK methods
... Show More The present study investigates the main parameters effect on the solenoid design as converging lens of charged particle beam passing through it. These parameters are solenoid magnetic field (B), solenoid radius (Ro) and the solenoid total length (L). The result indicates that the solenoid system is very sensitive to the change of these parameters. The solenoid acts as converge lens but may convert to diverging lens at some conditions. The best design obtained at (L=1100 mm, B=5000 gauss and Ro=150 mm).
In this study, silver nanoparticles (AgNPs) are synthesized using different chemical routes to obtain different sizes and shapes of nanoparticles by colloid chemistry with using stabilizing and reducing agent, which make them interesting for variety of physical applications. The morphology and structure of the synthesized AgNPs were characterized by UV-VIS spectra, Scanning Electron Microscopy (SEM) and Zeta potential to demonstrate that different sizes and shapes can by synthesized by different reductants in the presence of various stabilizing agents.
A new spectrophotometric method for individual and simultaneous determination of cefixime and cephalexin depending on the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of cefixime and cephalexin in concentration interval of (4– 24μg.ml-1 ) by measuring the amplitude of peak-to-base line, pea to peak at certain wavelengths and the area under peak at selected spectrum intervals. The methods showed reasonable precision and accuracy and have been applied to determine cefixime and cephalexin in two different pharmaceutical preparations.
The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which
... Show MoreThis paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.
Molar conductivity of ascorbic acid (AA) with some α–amino acids (glycine (Gly), methionine (Met), cysteine (Cys) and tryptophan (Trp)) in aqueous solution was measured at range temperatures from 298 K to 313 K. Λo. The limiting molar conductivity, KA, the association constant was calculated using the Shedlovsky method, and R, the association distance calculated by Stokes–Einstein equation. The thermodynamic parameters (The heat of association ΔHo, the change in Gibbs free energy ΔGo, the change of entropy ΔSo), and (ΔES), the activation e
... Show MoreThe objective of this study was to determine the concentration of trace element chromium(III) and thyroid peroxidase activity in human serum , and to find a relationship between the concentration of chromium(III) and thyroid peroxidase activity in serum of patients with hypothyroidism, hyperthyroidism and healthy subjects. Serum thyroid peroxidase was measured by enzyme linked radioimmunoassay(ELISA) method and chromium determination was by atomic absorption spectrophotometer .Comparing the values of chromium concentration and thyroid peroxidase activity in both samples showed that there were significant positive correlations between chromium levels and thyroid peroxidase activity(P<0.01, r=0.11).
... Show MoreA new ligand N-((4-(phenylamino) phenyl) carbamothioyl) acetamide (PCA) was synthesized by reaction of (4-amino di phenyl amine) with (acetyl isothiocyante) by using acetone as a solvent. The prepared ligand(PCA) has been characterization by elemental analysis (CHNS), infrared(FT-IR),electronic spectral (UV-Vis)&1H,13C- NMR spectra. Some Divalent Metal ion complexes of ligand (PCA) were prepared and spectroscopic studies by infrared(FT-IR), electronic spectral (UV-Vis), molar conductance, magnetic susceptibility and atomic absorption. The results measured showed the formula ofFall prepared complexes were [M (PCA)2 Cl2] (M+2 = Mn, Co, Ni, CU, Zn, Cd &Hg),the proposed geometrical structure for all complexes wereeoctahedral.