The aim of study To purify GPCR from a local strain of S. cerevisiae using Ion exchange and gel filtration chromatography techniques , by packing materials for columns which will be chosen of low cost comparing to the already used in published researches, which depend on the costly affinity chromatography and other expensive methods of purification. Local strain of S. cerevisiae chosen for extraction and purification of G-protein coupled receptor (GPCR) .The strains were obtained from biology department in Al- Mosul University, Iraq. The isolated colony was activated on Yeast Extract Pepton Dextrose Broth (YEPDB) and incubated at 30 C˚ for 24 h .Loop fully of the yeast culture was transferred to (10ml) of yeast extract peptone glucose agar (YEPGA) slant , then incubated at 30C˚for 24h , after that it was stored at 4C˚ ,the yeast cultures were reactivated and persevered after each two weeks period. S.cerevisiae was identified by morphological, microscopic characterization and biochemical test . The GPCR that extract from whole cell of S.cerevisiae was purified by ion exchange chromatography using DEAE-Sepharose ,the bound proteins (negatively charged) were then eluted using gradient concentration of NaCl ranged between( 0.1 -0.5M). Gel filtration chromatography using Sepharose 6B was applied as a second step of purification. The optical density for each fraction was measured at 280 nm by UV-VS spectrophotometer then the GPCR concentration was determined by using ELISA Kit . The fractions which gave the highest absorbance and concentration of GPCR were collected .The molecular weight of GPCR was determined by gel filtration chromatography using blue dextrin solution. Standard curve was plotted between log of molecular weight for standard protein and the ratio of Ve/Vo of GPCR . The purity of the GPCR that extracted and purified from whole cell of S, cerevisiae were carried out by using SDS-PAGE electrophoresis . In ion exchange chromatography the fraction were collected with 5 ml tube at a flow rate 0.5 ml/ min and eluted with gradient (0.1-0.5M) of sodium chloride solution. Two proteins peaks appeared after eluted by the gradient concentration of sodium chloride, while no protein peaks appeared in the washing fractions. The GPCR concentration was measured in the fractions of these two protein peaks, data indicated that GPCR located in the first protein peak (eluted at 0.1M of NaCl) at fraction numbers between 3 and 9, the maximum concentration of GPCR was 9.281 with specific activity 71.58(ng/mg)protein , 3.125 purification folds and72.9(%) yield while the second peaks (eluted at 0.4 M of NaCl) don't give any concentration for GPCR, thus its neglected. Gel filtration chromatography was used as second step of purification which applied by using sepharose 6B. Results show single active protein peaks appeared that identical with the peak of GPCR at fractions numbers(29-35). The maximum concentration of GPCR was 9.082 (ng/ml)was observed in these fractions. The specific activity for these fractions was 151.37 (ng/mg) protein with 6.608 purification folds and 39.64 (%) yield. The present study a chive a relatively high purification of GPCR from whole cell of a local strain S. cerevisiae with fold purification 6.608 and a yield of 39.64 % and molecular weight about~33KD.
Leucine aminopepotidase (LAP)[EC:3.4.11.1] activity has been assayed in (50) serum samples of patients with diabeties naphrophathy D.N (non-insulin dependent diabetic (NIDD) , and (50)serum sample of healthy individuals without any clinically detectable diseases have been as control group. The aim of this study is to measure leucine aminopeptidase activity and partially purifying the enzyme from sera of patients with diabetes nephropathy The results of this study revealed that Leucine aminopeptidase (LAP) activity of nephropathy patient’s serum shows a high signifiacant increase (p < 0.001) compared to that of the healthy subjects.LAP was purified from the serum of patients with diabetes nephropathy by dialysis and gel filtration (Se
... Show MoreA series of coumarin derivatives linked to amino acid ester side chains were synthesized and evaluated of their antibacterial and antifungal activity. The coumarin derivatives was alkylated by the ethyl bromoacetate and then using potassium carbonate to get alkylated hymecromone. Conventional solution method for amide bond formation was used as a coupling method between the carboxy-protected amino acids with acetic acid side chain of coumarin derivatives. The DCC/ HOBt coupling reagents were used for peptide bond formation. The proposed analogues were successfully synthesized and their structural formulas were consistent with the proposed struct
... Show MoreThe aim of this research was to indicate the opinion of the Iraqi consumer about the quality and safety of local food products, the questionnaire was included 19 questions for product quality, price, distribution and promotion as a tool to survey the opinions of 128 consumers in Baghdad, the data was analyzed by using percentage, weighted mean, and weight percent, the results obtained showed that the Iraqi consumer prefer local food products for their high quality and appropriate price, however they need attention to packaging, promotion and distribution.
Background: The healing period for bone–implant contact takes 3–6 months or even longer. Application of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) to implant surfaces has been of great interest on osseointegration due to its osteoinductive potential. The objective of this study was to evaluate the effect of ErhBMP-2 on implant stability. Materials and methods: A total of 48 dental implants were inserted in 15 patients. Twenty four implants coated with 0.5 mg/ml ErhBMP-2 (study group). The other 24 implants were uncoated (control group). Each patient was received at least two dental implants at the same session. Both groups were followed with repeated implant stability measurements by me
... Show MoreObjective: The present study aimed to shed light on the role of narghileh and cigarette smoking on immunity status of oral cavity by assess (C3 complement component, Immunoglobulin A, Total protein, α-Amylase and EBV IgG antibody). Method: Saliva levels in two smokers groups the first include 28 narghileh smokers and the second include 32 narghileh and cigarette smokers as well as 30 non-smokers consider as control. Results: As compared control, the levels of C3, IgA and total protein were significantly decreased, and the highest decreased was observed in saliva of narghileh and cigarette smokers, the result was (C3= 0.400±0.194 µg vs. 9.728±3.561 µg; IgA= 2.460±0.492 mg/dl vs. 5.048±0.937 mg/dl; Total protein= 170.20±45.93 mg% vs.
... Show MoreSeveral stress-strain models were used to predict the strengths of steel fiber reinforced concrete, which are distinctive of the material. However, insufficient research has been done on the influence of hybrid fiber combinations (comprising two or more distinct fibers) on the characteristics of concrete. For this reason, the researchers conducted an experimental program to determine the stress-strain relationship of 30 concrete samples reinforced with two distinct fibers (a hybrid of polyvinyl alcohol and steel fibers), with compressive strengths ranging from 40 to 120 MPa. A total of 80% of the experimental results were used to develop a new empirical stress-strain model, which was accomplished through the application of the parti
... Show MoreSilver Indium Aluminum Selenium AgIn1xAlxSe2 AIAS for x=01 thin films was deposited by thermal evaporation at RT and different︣︢︡ ︠︣1thickness 100 150 and 200 nm on the glass Substrate and p2Si wafer to produce AIAS/p3Si heterojunctionsolarcell4 Structural optical electrical and photovoltaicproperties6 are investigated for the samples XRD analysis reveals that all the deposited AIAS films show polycrystalline structure without any change due to increase of thickness Average diameter and roughness calculated from AFM images shows an increase in its value with increasing thickness The optical absorbance and transmittance for samples are measured using a spectrometer type UV Visible 1800 spectra1photometer to study the energy6gap The
... Show MoreProsthetic hands are compensatory devices for the hand amputees as a result of injury, various accidents or birth deformities, types of prosthetic hand vary depending on the mechanism they operate and how they perform. There are common types in use that are characterized by their complex mechanisms, which are difficult for the amputee to use or exclude use because of their high cost, therefore the aim of this research is to design an artificial hand that is suitable in terms of simplicity of use and low cost and similar to a natural hand with regard to dimensions and shape that operated in the mechanism of links. This research involves Stress and strain analysis of the prosthetic hand and its fingers that modelled from (Petg CR)
... Show More