Preferred Language
Articles
/
HBZnUYkBVTCNdQwC54mE
Extraction of cobalt(II) from aqueous solution by N,N′-carbonyl difatty amides
...Show More Authors

The development of economic and environmentally friendly extractants to recover cobalt metal is required due to the increasing demand for this metal. In this study, solvent extraction of Co(II) from aqueous solution using a mixture of N,N0-carbonyl difatty amides (CDFAs) synthesised from palm oil as the extractant was carried out. The effects of various parameters such as acid, contact time, extractant concentration, metal ion concentration and stripping agent and the separation of Co(II) from other metal ions such as Fe(II), Ni(II), Zn(III) and Cd(II) were investigated. It was found that the extraction of Co(II) into the organic phase involved the formation of 1:1 complexes. Co(II) was successfully separated from commonly associated metal ions such as Fe(II), Ni(II), Zn(III) and Cd(II). Co(II) stripping from the loaded organic phase was studied in aqueous solution. These results are useful to recover Co(II) from aqueous solution utilising (CDFAs) as an extractant.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Jun 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Characterizations of Fe/Mn binary oxide by nitrogen adsorption
...Show More Authors

View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Preparation of Polyvinyl Alcohol/ Tio2 Nano Fiber by Electrospinning
...Show More Authors

In this research we prepared nanofibers by electrospinning from
poly (Vinyl Alcohol) /TiO2. The spectrum of the solution (Emission)
was studied and found to be at 772 nm, several process parameters
were such as concentration of TiO2 , and the effect of distance from
nozzle tip to the grounded collector (gap distance). The result of the
lower concentration of, the smaller the diameter of nanofiber is.
Increasing the gap distance will affect nanofibers diameter

View Publication Preview PDF
Publication Date
Tue Sep 11 2018
Journal Name
Association Of Arab Universities Journal Of Engineering
Estimation of the Total Dissolved Salts by Hydrometer Test
...Show More Authors

View Publication
Publication Date
Thu Jun 07 2012
Journal Name
Scientific Research And Essays
Security verification of the return routability protocol by Murphi
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Solid State Technology
Durability Of Gypsum Soil Treated By Using Polyurethane Polymer
...Show More Authors

Gypseous soils represented one of the most complex salty soils that faced the geotechnical engineers. Structures that built on gypsum soil will undergo unexpected distortions that will eventually contribute to catastrophic failure. The purpose of this article is to understand the durability of gypsum soil against wetting drying cycles after improvement with polyurethane polymer especially investigate the effect of the wetting-drying cycle on collapsibility. The soil was brought from Sawa lake in AL-Muthanna Governorate in Iraq, with gypsum content 65.5%,  A set of Odometer tests were performed to determine the collapsibility potential (CP) for treated and untreated gypsum soil.  The result shows that adding a different per

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Brazilian Journal Of Analytical Chemistry
Determination of insecticides in different commercialformulations by Gradient HPLC
...Show More Authors

A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.

... Show More
Publication Date
Wed May 01 2019
Journal Name
Iraqi Journal Of Biotechnology
Identification of Leishmania donovani Isolates by Polymerase Chain Reaction
...Show More Authors

Leishmaniasis is endemic ofIraq in both cutaneous and visceral form. The available tools for diagnosis and detection of Leishmaniaare nonspecific and may interfere with other species. In this study, Polymerase Chain Reaction (PCR) has been used to identify Iraqi isolate of visceral leishmaniasis (MHOM/ IQ/2005/MRU15) which a previously diagnosed by classical serological tests. PCR amplificationwas carried out using species-specific primers of Leishmania donovani. Four primer pairs of mini-circle DNA and ITS-1 were used.13A/13B, which is used to identify Leishmaniaas a genus, NM12, LITSR/L5.8S and BHUL18S, were used to detect the sub species of L. donovani.The result ofPCR

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 14 2003
Journal Name
Journal Of Engineering
Slope Stability of Embankments by the Finite Element Method
...Show More Authors

Publication Date
Mon Jun 04 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Dissolution Enhancement of Raltegravir by Hot Melt Extrusion Technique
...Show More Authors

The objective of the study to develop an amorphous solid dispersion for poorly soluble raltegravir by hot melt extrusion (HME) technique. A novel solubility improving agent plasdone  s630 was utilized. The HME raltegravir was formulated into tablet by direct compression method. The prepared tablets were assessed for all pre and post-compression parameters. The drug- excipients interaction was examined by FTIR and DSC. All formulas displayed complying with pharmacopoeial measures. The study reveals that formula prepared by utilizing drug and plasdone S630 at 1:1.5 proportion and span 20 at concentration about 30mg (trail-6) has given highest dissolution rate than contrasted with various formulas of raltegravir.

Keywor

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Enhanced efficiency of CdTe Photovoltaic by thermal evaporation Vacuum
...Show More Authors

Crossref (20)
Crossref