Preferred Language
Articles
/
H0IqSZoBMeyNPGM3_cAF
The Effect of Wall'S Porous Liner on MHD Couette Flow of Carreau Fluid in an Inclined Channel under the Convective Conditions
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Oct 04 2026
Journal Name
Iraqi Journal Of Mechanical And Material Engineering
THE INFLUENCE OF FRICTION FACTOR ON THE COMBINED CONVECTIVE AND RADIATIVE HEAT TRANSFER IN A RECTANGULAR DUCT WITH INTERIOR CIRCULAR CORE
...Show More Authors

View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Sport Tk - Revista Euro Americana De Ciencias Del Deporte
Analysis of the amount of lost fluids, some blood components and mineral salts in volleyball under hot weather conditions
...Show More Authors

Scopus (7)
Scopus
Publication Date
Tue Jul 11 2023
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Analysis of the amount of lost fluids, some blood components and mineral salts in volleyball under hot weather conditions
...Show More Authors

The research objective was to study the amount of lost fluids, some blood components and mineral salts in volleyball players under hot weather conditions. The sample of the present study was composed of 12 volleyball players of Al-Sinaa Club (Baghdad, Iraq) in the 2022/2023 season. The variables analyzed in this study were: Heart rate before and after exercise, internal and external body temperature before and after exertion, potassium ion, sodium ion, calcium ion, and the amount of fluid lost (the player's weight) before and after the exercise. The tests were conducted at a temperature between 42-47 degrees Celsius. The maximum anaerobic exercise was performed with volleyball. The results showed that to play volleybal

... Show More
View Publication
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Tue Jul 11 2023
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Analysis of the amount of lost fluids, some blood components and mineral salts in volleyball under hot weather conditions
...Show More Authors

The research objective was to study the amount of lost fluids, some blood components and mineral salts in volleyball players under hot weather conditions. The sample of the present study was composed of 12 volleyball players of Al-Sinaa Club (Baghdad, Iraq) in the 2022/2023 season. The variables analyzed in this study were: Heart rate before and after exercise, internal and external body temperature before and after exertion, potassium ion, sodium ion, calcium ion, and the amount of fluid lost (the player's weight) before and after the exercise. The tests were conducted at a temperature between 42-47 degrees Celsius. The maximum anaerobic exercise was performed with volleyball. The results showed that to play volleybal

... Show More
View Publication
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Tue Oct 24 2023
Journal Name
Chemical Engineering & Technology
Electrodeposition of Manganese Dioxide under Different Conditions: Application of MnO<sub>2</sub>/Carbon Fibers in the Electrosorption Process
...Show More Authors
Abstract<p>Anodic electrodeposition was used to synthesize a composite electrode of nanostructured manganese dioxide/carbon fiber (CF) galvanostatically. Different characterization results of the nanostructured MnO<sub>2</sub> were obtained by varying the H<sub>2</sub>SO<sub>4</sub> concentration and the current density. Field emission scanning electron microscopy, X‐ray diffraction, and atomic force microscopy were utilized to characterize the prepared composite electrodes. The best conditions were: 0.3 mA cm<sup>−2</sup> current density and 0.64 M H<sub>2</sub>SO<sub>4</sub> concentration. The electrosorption performance of the MnO<sub></sub></p> ... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Effect of Oscillatory Motion in Enhancing the Natural Convection Heat Transfer from a Vertical Channel
...Show More Authors

This paper reports an experimental study regarding the influence of vertical oscillations on the natural convection heat transfer from a vertical channel. An experimental set-up was constructed and calibrated; the vertical channel was tested in atmosphere at 25o
C. The channel-to-ambient temperature difference was varied with the power supply to the electrical heater ranging between
15W to 70W divided into five levels. Data sets were measured under different operating condition from a test rig under six vibrating velocities (VVs) levels ranging from (5-30 m/s) in addition to the stationary state. The results show that the maximum heat transfer enhancement factor (E) occurs at Rayleigh number (Ra=2.328×103 ) and vibrational Reynol

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Effect of exercises on the VertiMax device on the endurance of under 16-years of age discus throwers
...Show More Authors

The primary aim of the present study was to prepare a set of exercises on the multi-resistor VertiMax device and to identify the effect of these exercises on the development of the endurance of discus throwers under 16 years old. The design of the present study was experimental. Participants were selected using purposive sampling method. A total of 5 discuss players constituted the sample of the study. The authors found a significant improvement in the levels of endurance and performance as a result of the training on the VertiMax device. Therefore, it is recommendable to use exercises on the VertiMax device to improve the endurance and performance of under 16-years of age discus throwers.

View Publication
Scopus Crossref
Publication Date
Mon Sep 30 2024
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The effect of hydrothermal conditions on surface properties of synthesized nano SBA-15 using sodium silicate
...Show More Authors

A successful synthesis of mesoporous Santa Barbara amorphous (SBA-15) with nanoparticle size was attempted using prepared sodium silicate from Iraqi high silica sand. EO20PO70EO20 copolymer was used as a template at highly acidic conditions (pH < 2). The effect of crystallization temperature of (100, 110, 120, and 130 0C), and crystallization time of (24, 48, 72, and 120 h) on surface properties was studied. The experiments were characterized using XRD, FTIR, AFM, BET, and FESEM. The XRD and FTIR tests represent amorphous SBA-15 without any impurities. Decreasing average particle size distribution increased the surface area, and decreased the porosity (pore volume, and pore size) in all experiments. The texture properties were su

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sun Dec 02 2012
Journal Name
Baghdad Science Journal
Unsteady Magnetohydrodynamics oscillating flow of third order fluid with central free stream velocity
...Show More Authors

In this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised

View Publication Preview PDF
Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study for Assessment of Cutting Density Effect on Hole Cleaning Efficiency in Inclined and Horizontal Wells
...Show More Authors

The poor hole cleaning efficiency could causes many problems such as high torque, drag, poor hydraulics and pipe stuck. These inherent problems result in an avoidable high operation cost which this study tried to address.  In this study, the effect of cutting density on hole cleaning efficiency in deviated and horizontal wells was investigated. Experiments were conducted using 40 feet (12 m) long of flow loop made from iron and PVC. However, the test section was made from PVC with (5.1m) long and (4” ID) for outer pipe and (2” OD) inner pipe. The cutting transport ratio (CTR) was determined from weight measurements for each test. Cutting Transport Ratio has been investigated for effects of the following parameters; flow rate, cu

... Show More
View Publication Preview PDF
Crossref (5)
Crossref