This study focused on the expression and regulation of BRCA1 in breast cancer cell lines compared to normal breast. BRCA1 transcript levels were assessed by real time quantitative polymerase chain reaction (RT-qPCR) in the cancer cell lines. Our data show overexpression of BRCA1 mRNA level in all the studied breast cancer cell lines: MCF-7, T47D, MDA-MB-231 and MDA-MB-468 along with Jurkat, leukemia T-lymphocyte, the positive control, relative to normal breast tissue. To investigate whether a positive or negative correlation exists between BRCA1 and the transcription factor E2F6, three different si-RNA specific for E2F6 were used to transfect the normal and cancerous breast cell lines. Interestingly, strong negative relationship was found between BRCA1 and E2F6, in which depletion of E2F6 in MCF-10A, the normal breast cell line, resulted in more than four-fold increased expression of BRCA1 transcript level. On the other hand, our findings suggest that E2F6 might lost control on BRCA1 in breast cancer cells. E2F6 knockdown by either of two specific siRNA (i.e. si-E2F6#1 or si- E2F6#2) had no influence on the BRCA1 expression in MCF-7 cells. Although, transfecting these cells with si-E2F6#3 showed overexpression of BRCA1 compared to cells transfected with scrambled negative control.
An analytical method and a two-dimensional finite element model for treating the problem of laser heating and melting has been applied to aluminum 2519T87and stainless steel 304. The time needed to melt and vaporize and the effects of laser power density on the melt depth for two metals are also obtained. In addition, the depth profile and time evolution of the temperature before melting and after melting are given, in which a discontinuity in the temperature gradient is obviously observed due to the latent heat of fusion and the increment in thermal conductivity in solid phase. The analytical results that induced by laser irradiation is in good agreement with numerical results.
Simple, sensitive and accurate two methods were described for the determination of terazosin. The spectrophotometric method (A) is based on measuring the spectral absorption of the ion-pair complex formed between terazosin with eosin Y in the acetate buffer medium pH 3 at 545 nm. Method (B) is based on the quantitative quenching effect of terazosin on the native fluorescence of Eosin Y at the pH 3. The quenching of the fluorescence of Eosin Y was measured at 556 nm after excitation at 345 nm. The two methods obeyed Beer’s law over the concentration ranges of 0.1-8 and 0.05-7 µg/mL for method A and B respectively. Both methods succeeded in the determination of terazosin in its tablets
Silymarin (SM) is a plant extract obtained from Silybum marianum( milk thistle) . It is class II type drug according to Biopharmaceutics Classification System with low bioavailability due to its low solubility.
Micro/nanonization during crystallization, surface modification and crystal structure modification may improve the dissolution rate of poorly water-soluble drugs.
The aim of this study was to increase the water solubility and dissolution rate of SM by in-situ micronization using solvent change either by stirring or ultrasonic method. Stabilizers like Gelatin, PVP-K30, HPMC15, Pulullan were used to stabilize the prepared ultrafine crystals. Effect of type and concentration of hydrophilic polymer, solv
... Show MoreFinding orthogonal matrices in different sizes is very complex and important because it can be used in different applications like image processing and communications (eg CDMA and OFDM). In this paper we introduce a new method to find orthogonal matrices by using tensor products between two or more orthogonal matrices of real and imaginary numbers with applying it in images and communication signals processing. The output matrices will be orthogonal matrices too and the processing by our new method is very easy compared to other classical methods those use basic proofs. The results are normal and acceptable in communication signals and images but it needs more research works.
The CIGS/CdS p-n junction thin films were fabricated and deposited at room temperature with rate of deposition 5, and 6 nm secG1 , on ITO glass substrates with 1mm thickness by thermal evaporation technique at high vacuum pressure 2×10G5 mbar, with area of 1 cm2 and Aluminum electrode as back contact. The thickness of absorber layer (CIGS) was 1 µm while the thickness of the window layer CdS film was 300 nm. The X-ray Diffraction results have shown that all thin films were polycrystalline with orientation of 112 and 211 for CIGS thin films and 111 for CdS films. The direct energy gaps for CIGS and CdS thin films were 1.85 and 2.4 eV, respectively. Atomic Force Microscopy measurement proves that both films CIGS and CdS films have nanostru
... Show MoreKE Sharquie, AA Noaimi, Journal of the Saudi Society of Dermatology & Dermatologic Surgery, 2012 - Cited by 36
ZnO-nanoflowers on a transparent conductive tin-doped In2O3 (ITO) glass substrate have been successfully prepared via a simple and efficient growth approach that is combining of dip coating and hydrothermal processes. One thin layer of ZnO nanoparticles is prepared by dip coating method followed by hydrothermally grown of ZnO nanoflowers at low temperature. The morphology and structure of ZnO-nanoflowers were inspected by field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD), respectively. The optical absorption and photoluminescence spectra of ZnO-nanoflowers are also investigated. The ZnO-nanoflowers photoanode sho
Structural and optical properties were studied as a function of Nano membrane after prepared, for tests. Nano membrane was deposited by the spray coating method on substrates (glass) of thickness 100 mm. The X-ray diffraction spectra of (CNTs, WO3) were studied. AFM tests are good information about the roughness, It had been designed electrolysis cell and fuel cell. Studies have been performed on electrochemical parameters.
The Estimation Of The Reliability Function Depends On The Accuracy Of The Data Used To Estimate The Parameters Of The Probability distribution, and Because Some Data Suffer from a Skew in their Data to Estimate the Parameters and Calculate the Reliability Function in light of the Presence of Some Skew in the Data, there must be a Distribution that has flexibility in dealing with that Data. As in the data of Diyala Company for Electrical Industries, as it was observed that there was a positive twisting in the data collected from the Power and Machinery Department, which required distribution that deals with those data and searches for methods that accommodate this problem and lead to accurate estimates of the reliability function,
... Show More