Two‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤
With the increasing intensity of the ecological and environmental problems and the scarcity of fresh water, this paper was introduced to investigate the ability to use treated wastewater as a cooling media via studying its behavior throughout a cooling tower. The simultaneous transfer of heat and mass from the treated wastewater to air over splash-fill packing arranged in a zigzag manner was studied. The characteristic of the cooling tower, the outlet water temperature, and the rejected heat were investigated as the water-to-air ratio and inlet water temperature were varied. The core results show that the cooling tower of the tower decreases with increasing water-to-air ratio, and increases with the raise of inlet water temperature.
... Show MoreA twisted-fin array as an innovative structure for intensifying the charging response of a phase-change material (PCM) within a shell-and-tube storage system is introduced in this work. A three-dimensional model describing the thermal management with charging phase change process in PCM was developed and numerically analyzed by the enthalpy-porosity method using commercial CFD software. Efficacy of the proposed structure of fins for performing better heat communication between the active heating surface and the adjacent layers of PCM was verified via comparing with conventional longitudinal fins within the same design limitations of fin material and volume usage. Optimization of the fin geometric parameters including the pitch, numb
... Show MoreA localized stenosis or aneurysm is a discontinuity that presents the pulse wave produced by the contracting heart with a reflection site. However, neither wave speed ( c) in these discontinuities nor the size of reflection in relation to the size of the discontinuity has been adequately studied before. Therefore, the aim of this work is to study the propagation of waves traversing flexible tubes in the presence of aneurysm and stenosis in vitro. We manufactured different sized four stenosis and four aneurysm silicone sections, connected one at a time to a flexible ‘mother’ tube, at the inlet of which a single semi-sinusoidal wave was generated. Pressure and velocity were measured simultaneously 25 cm downstream the inlet of th
... Show MoreChilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show MoreThe bile salt hydrolase gene (bshA), encoding bile salt hydrolase enzyme (EC 3.5.1.24) from probiotic isolate Lactobacillus acidophilus Ar strain which is responsible for assimilation cholesterol were studied in the present work. About 801 bp in length DNA fragment of Lb. acidophilus Ar strain was amplified by PCR techniques. Two restriction sites (PstI/SacI) were added to each end of that fragment for manipulation of DNA during cloning. Amplified fragment inserted into pJET1.2\blunt end vector and pMG36e vector respectively. pJET1.2\blunt end vector is overexpression plasmid for E. coli MC1022, and pMG36e vector is a shuttle vector which is able to replicate in both E. coli and lactic acid bacteria. The resulted constructs were named as pJ
... Show MoreA survey of haemoproteids among the eight species of Iraq rallids were carried out in the
middle, south, and west of Iraq. Two haemoproteods were recorded, Haeomproteus porzanae
(Galli-Valerio, 1907) as a new record for Iraq and the new species H. baghdadensis described
from Fulica atra L. collected in the middle of Iraq.
The study aimed to survey mushroom species from fields among herbs, palm trunks, and trees in central Iraq and to identify them on the basis of morphological and molecular characteristics. As a molecular identification result with polymerase chain reaction six species were recorded (with eight isolates): Agaricus bitorquis (Quéllt) Saccardo. 1887 (SHA14); Candolleomyces candolleanus (Fr.) D. Wächter & Melzer, 2020 (SHA15); Cyclocybe cylindracea (D.C.) Vizzini & Angelini, 2014 (SHA13); Leucoagaricus hesperius Vellinga, 2010 (SHA16); Volvariella sp. (SHA17), and Volvopluteus gloiocephalus (D. C.) Vizzini, Contu & Justo, 2011 (SHA10, SHA101 and SHA12), belonging to four families of Basidiomycetes: Agaricaceae, Pluteaceae,
... Show MoreThe study of homomorphisms in cubic sets is considered one of the important concepts that transfer algebraic properties between different structures, so we study a homomorphism of a cubic set of a semigroup in a KU-algebra and defined the product of two cubic sets in this structure. Firstly, we define the image and the inverse image of a cubic set in a KU-semigroup and achieve some results in this notion. Secondly, the Cartesian product of cubic subsets in a KU-semigroup is discussed and some important characteristics are proved.
Psi prepared by Electrochemical etching technique at invariable etching current density of 10 mA/cm2 and at different times (7 and 17) min. The porous Si structure was studied using XRD, (FE-SEM) and EDS. The process of sensing NH3 gas is carried out at different operating temperatures (R.t,80,130 and 200)°C and the gas concentration is constant. It is measured by changing the resistance of the sensor as a function of exposure time to the gas. The result showed the XRD patterns of the PS at (7 and 17) min etching time. the peak samples at (111) around 2θ = 28.5°. It is observed that the peak intensity declines with rising the etching time,