The laminar fluid flow of water through the annulus duct was investigated numerically by ANSYS fluent version 15.0 with height (2.5, 5, 7.5) cm and constant length (L=60cm). With constant heat flux applied to the outer duct. The heat flux at the range (500,1000,1500,2000) w/m2 and Reynolds number values were ≤ 2300. The problem was 2-D investigated. Results revealed that Nusselt number decrease and the wall temperature increase with the increase of heat flux. Also, the average Nusselt number increase as Re increases. And as the height of the annulus increase, the values of the temperature and the local and average Nusselt number increase.
Over the last few decades the mean field approach using selfconsistent
Haretree-Fock (HF) calculations with Skyrme effective
interactions have been found very satisfactory in reproducing
nuclear properties for both stable and unstable nuclei. They are
based on effective energy-density functional, often formulated in
terms of effective density-dependent nucleon–nucleon interactions.
In the present research, the SkM, SkM*, SI, SIII, SIV, T3, SLy4,
Skxs15, Skxs20 and Skxs25 Skyrme parameterizations have been
used within HF method to investigate some static and dynamic
nuclear ground state proprieties of 84-108Mo isotopes. In particular,
the binding energy, proton, neutron, mass and charge densities
Visceral leishmaniasis (VL) is a parasitic disease that affects public health. It is described by weight reduction, irregular fever bouts, anemia, and amplification of the spleen and liver.
Three concentrations (15.6, 31.2, and 62.5 μg/mL) were used to find the potency of an aqueous extract of
Visceral leishmaniasis (VL) is a parasitic disease that affects public health. It is described by weight reduction, irregular fever bouts, anemia, and amplification of the spleen and liver.
Three concentrations (15.6, 31.2, and 62.5 μg/mL) were used to find the potency of an aqueous extract of
The flow emission rate of hard photons from lowest order the QCD processes for quark-anti quark annihilation processes in plasma media at high temperatures (175, 200, 225, 250 and 275 MeV) have been study. In these framework photons, the flow photons emission is calculate according to quark-antiquark annihilation using the quantum chromodynamic theory and solves the ultrarelativistic equation with MATLAP program. Due to the results, we show increases flow photons rate with increases strength coupling and increases with increases temperature of media, it indicate that logarithmically divergent thermal effect on photons product. The critical temperature (Tc=155 to 195 MeV) effect on the quarks confined in hadronic matter phase, it is importan
... Show MoreNew microphotometer was constructed in our Laboratory Which deals with the determination of Molybdenum (VI) through its Catalysis effect on Hydrogen peroxide and potasum iodide Reaction in acid medium H2SO4 0.01 mM. Linearity of 97.3% for the range 5- 100 ppm. The repeatability of result was better than 0.8 % 0.5 ppm was obtanined as L.U. (The method applied for the determination of Molybdenum (VI) in medicinal Sample (centrum). The determination was compared well with the developed method the conventional method.
Background: Sclerotherapy is a simple treatment modality for treatment of infantile hemangioma and slow-flow vascular malformations; Polidocanol is a mild sclerosing agent that is traditionally used in treatment of varicose veins. This study aims to evaluate the effectiveness, treatment outcome, and complications of polidocanol foam sclerotherapy for infantile hemangioma and slow-flow vascular malformations. Materials and methods: Between March 2013 and December 2014, seventeen patients with infantile hemangioma and slow-flow vascular malformations treated with polidocanol 1% foam sclerotherapy. Foam was prepared by Tessari’s method. Injection performed under general or local anesthesia, injections were repeated (if necessary) on mon
... Show MoreThis work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C. As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power
... Show MoreIn this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.