Preferred Language
Articles
/
GxZfGIcBVTCNdQwC-zYR
Dimensional analysis of predicting the removal of chemical oxygen demand from domestic wastewater using moving bed biofilm reactor
...Show More Authors

Municipal wastewater sources are becoming increasingly important for reuse, for irrigation purposes, so they must be treated to meet environmentally friendly local or global standards. The aim of this study is to establish, calibrate, and validate a model for predicting chemical oxygen demand for the pilot plant of mobile biofilm reactors operating from municipal wastewater in Maaymyrh located in Hilla city Using the approach of dimensional analysis. The approach of Buckingham's theorem was used to derive a model of dimensional analysis design for the forecast of (COD) in the pilot plant. The effluent concentration (COD) It has been derived as a result of the influential concentration of (COD), dissolved oxygen (DO), volume of pilot plant (V), influent flow rate (Q), Specific surface area for carriers (Sp), Efficient of removal of organic materials (ER) and detention time (t). With the first 80 data sets and due to the lack of empirical literature, the model was calibrated and then verified with the remaining 40 data sets . the results showed A strong coefficient of The (R = 0.939) correlation Between the effluent concentration measured and computed (COD) was get by the model verification at a significance level of (0.05). The determination coefficient (R2) has shown that the evolved model explains(88.33) percent of the variance in the experimental results. Therefore, the prediction of (COD) concentration in the pilot plant from the developed model would be feasible.

Scopus Crossref
View Publication
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Bioadsorption of Heavy Metals From Industrial Wastewater Using Some Species of Bacteria
...Show More Authors

Three isolated bacteria were examined to remove heavy metals from the industrial wastewater of the Diala State Company of Electrical Industries, Diyala-Iraq. The isolated bacteria were identified as Pseudomonas aeruginosa, Escherichia coli and Sulfate Reducing Bacteria (SRB). The three isolates were used as an adsorption factor for different concentrations of Lead and Copper (100, 150, and 200 ppm.), in order to examine the adsorption efficiency of these isolates. In addition, the effect of three factors on heavy metals adsorption were examined; temperature (25, 30, and 37 ?C), pH (3 and 4.5) and contact time (2 and 24 hrs). The results showed that the highest level of lead adsorption was obtained at 37 ?C by E. coli, P, aerugenosa and

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Compare Prediction by Autoregressive Integrated Moving Average Model from first order with Exponential Weighted Moving Average
...Show More Authors

The prediction process of time series for some time-related phenomena, in particular, the autoregressive integrated moving average(ARIMA) models is one of the important topics in the theory of time series analysis in the applied statistics. Perhaps its importance lies in the basic stages in analyzing of the structure or modeling and the conditions that must be provided in the stochastic process. This paper deals with two methods of predicting the first was a special case of autoregressive integrated moving average which is ARIMA (0,1,1) if the value of the parameter equal to zero, then it is called Random Walk model, the second was the exponential weighted moving average (EWMA). It was implemented in the data of the monthly traff

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 08 2023
Journal Name
Iraqi Journal Of Science
Physico-chemical and Biological Variables of Hospitals Wastewater in Erbil City
...Show More Authors

Three hospitals were chosen(Maternity hospital, Raperin hospital and Rhizgari hospital) for the present survey within Erbil city. Water samples were collected at regular monthly interval periods beginning in January 2012 to December 2012. pH of all the studied sites were found to be up 7. Electrical conductivity ranged from (1318-1790 μs.cm-1 in Maternity Hospital, 1770-2232 μs.cm-1 in Raperin Hospital, 1010-1615 μs.cm-1 in Rhizgari Hospital). BOD5 and COD values ranged from 22- 80 mg.L1 and 280- 1410 mg.L-1 respectively, this indicated a high pollution situation in the studied sites in respect to organic matter content. The quantitative analysis of counted microorganisms was more than that describe by WHO guidelines standard.

View Publication Preview PDF
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Isolation and Identification of Endophytic Fungi from Aloe vera Leaves and Chemical Analysis of the Alcoholic Extract of the Leaves Using HPLC, GC, and GC-Mass Devices
...Show More Authors

The study's goals were to separate and identify endophytic fungi from Aloe vera leaves by looking at their morphology and molecules, as well as to find the chemical compounds in the leaf extract by using HPLC, GC, and GC-Mass instruments. The results showed that 53 endophytic fungi were isolated from a total of 120 pieces of A. vera leaves, with a total colonization rate of 44.16%. The fungus Aspergillus terreus had a colonization rate of 14.16%; Aspergillus niger had a colonization rate of 13.33%; Penicillium chermesinum demonstrated a colonization rate of 6.66%; Paecilomyces variotii had a colonization rate of 2.5%; Talaromyces radicus; and Aspergillus flavus achie

... Show More
View Publication
Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
The performance of MnO<sub>2</sub>/graphite electrode for TOC removal from wastewater by indirect electrochemical oxidation process
...Show More Authors

Electrochemical oxidation in the presence of sodium chloride used for removal of phenol and any other organic by products formed during the electrolysis by using MnO2/graphite electrode. The performance of the electrode was evaluated in terms fraction of phenol and the formed organic by products removed during the electrolysis process. The results showed that the electrochemical oxidation process was very effective in the removal of phenol and the other organics, where the removal percentage of phenol was 97.33%, and the final value of TOC was 6.985 ppm after 4 hours and by using a speed of rotation of the MnO2 electrode equal to 200 rpm.

View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
REMOVAL OF PHENOLIC COMPUNDS FROM AQUEOUS SOLUTIONS BY ADSOPTION ONTO ACTIVTED CARBONS PREPARED FROM DATE STONES BY CHEMICAL ACTIVATION WITH FeCl3
...Show More Authors

Activated carbon prepared from date stones by chemical activation with ferric chloride (FAC) was used an adsorbent to remove phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) from aqueous solutions. The influence of process variables represented by solution pH value (2-12), adsorbent to adsorbate weight ratio (0.2-1.8), and contact time (30-150 min) on removal percentage and adsorbed amount of Ph and PNPh onto FAC was studied. For PNPh adsorption,( 97.43 %) maximum removal percentage and (48.71 mg/g) adsorbed amount was achieved at (5) solution pH,( 1) adsorbent to adsorbate weight ratio, and (90 min) contact time. While for Ph adsorption, at (4) solution pH, (1.4) absorbent to adsorbate weight ratio, and (120 min) contact

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Dec 01 2007
Journal Name
Electrochimica Acta
Scale-up of a fixed bed electrochemical reactor consisting of parallel screen electrode used for p-aminophenol production
...Show More Authors

View Publication
Scopus (26)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Tue Sep 25 2018
Journal Name
Iraqi Journal Of Science
Using Multiattribute Analysis to Predicting Effective Porosity of Yamama Formation in Nasriya Oilfield Southern Iraq
...Show More Authors

Emerge application was used in Hampsson-Russell programs and that uses a combination of multiple 3D or 2D seismic attributes to predict some reservoir parameter of interest. In this research used the seismic inversion technique was performed on post-stack three dimensions (3D) seismic data in Nasriya oilfield with five wells  and then used this results in  Emerge analysis (training and application) were used to estimate reservoir properties (effective porosity) with multiattribute analysis derive relations  between them at well locations. The horizon time slice of reservoir units of (Yb1, Yb3 and Yc) of Yamama Formation was made for property (effective porosity) to confirm match results and enhancement trends within these

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 03 2022
Journal Name
Egyptian Journal Of Chemistry
A Novel Bio-electrochemical Cell with Rotating Cylinder Cathode for Cadmium Removal from Simulated Wastewater
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Iraqi Journal Of Science
Removing Cobalt ions from Industrial Wastewater Using Chitosan
...Show More Authors

      In batch experiments, a natural chitosan adsorbent was employed to extract cobalt ions from industrial wastewater under varied parameters of starting concentration, adsorbent weight, pH, and contact duration. The adsorbent was examined using FTIR, XRD, and AFM. For an initial cobalt ion concentration of 5x10-2 mol/l at pH 6, time 35 minutes, temperature 25 °C, and adsorbing dose 0.1 g, the results showed a maximum removal percentage of 99.0 percent. The Freundlich isotherm and the pseudo-second order kinetic model both suit the experimental data well. According to thermodynamic studies, the process was spontaneous and endothermic.

View Publication Preview PDF
Scopus (3)
Scopus Crossref