Preferred Language
Articles
/
GuYymp0BmraWrQ4d9lq7
NUMERICAL AND EXPERIMENTAL INVESTIGATIONOF STEAM FILM CONDENSATION ON A VERTICAL TUBE
...Show More Authors

 Film condensation of steam on a vertical tube is investigated numerically and experimentally,   in the present work. A mathematical model was set based on the basic conservation laws of mass   and energy, Nusselts analysis of film condensation, and empirical equations available in the   literature. Then, a simulation program in FORTRAN language was developed which simulates the   film condensation of steam on a vertical tube. A complete steam tables subprogram was also   developed and incorporated with the main program. The experimental work was carried out using a   steam condensation test bench. The inlet and outlet cooling water temperatures, steam temperature   and pressure, tube surface temperature at center, and cooling water flow rate are recorded during   each experimental test run. The inlet cooling water temperature, steam temperature, and cooling   water flow rate are used as an input for the numerical program, then the program calculates tube   surface temperature distribution, cooling water temperature distribution, local heat transfer rate,   local condensation heat transfer coefficient, condensate boundary layer thickness distribution, total   heat transfer rate, and average condensation heat transfer coefficient. The effect of various   parameters on the condensation heat transfer coefficient, such as steam temperature, steam-surface   temperature difference, and the presence of non-condensable gas were investigated and reported   graphically. It was found that increasing (steam-surface) temperature difference while keeping the   steam temperature constant results in an increase in condensate boundary layer thickness, which in   turn causes a decrease in condensation heat transfer coefficient. On the other hand, increasing steam   temperature and keeping the (steam-surface) temperature difference constant leads to an increase in   condensation heat transfer coefficient. In addition, the presence of non-condensable gas with   different concentrations was also investigated and it was shown that it causes a noticeable reduction   in the average condensation heat transfer coefficient. An equation for calculating average   condensation heat transfer coefficient on a vertical tube was also developed. The experimental data   obtained from the test runs were compared with numerical results and showed good agreement.   Thus, it can be concluded that the present computational program is suitable for simulating steam   condensation on a vertical tube. 

Crossref
View Publication
Publication Date
Sun Feb 02 2025
Journal Name
Engineering, Technology & Applied Science Research
A Numerical Study of Concrete Composite Circular Columns encased with GFRP I-Section using the Finite Element Method
...Show More Authors

This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Engineering
Numerical Study of Convective Heat Transfer in a Rectangular Channel Inserted with Metal Foam of Gradient Pore Density
...Show More Authors

Metal foam has recently been used in many engineering applications, such as solar collectors, heat exchangers, and cooling of electronic devices, which calls for studying different cases of using metal foam in these applications. The current study conducts a numerical analysis of heat transfer and fluid flow characteristics for air in a rectangular channel filled with high-porosity copper foam. The study examined the thermal performance for two cases of gradient pore density, which are arranged as (10-20-40) PPI and (40-20-10) PPI. These cases were compared with two other cases for constant pore density, 10 and 40 PPI, and empty cases. The ANSYS FLUENT 20.0 employed the Darcy-Forchheimer extended Brickman model in the two-dimensiona

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jun 10 2010
Journal Name
Iraqi Journal Of Laser
Experimental Investigation of a Laser Wireless Video Communication System Using Intensity Modulated /Direct Detection Technique
...Show More Authors

In this work Laser wireless video communication system using intensity modualtion direct
detection IM/DD over a 1 km range between transmitter and receiver is experimentally investigated and
demonstrated. Beam expander and beam collimeter were implemented to collimete laser beam at the
transmitter and focus this beam at the receiver respectively. The results show that IM/DD communication
sysatem using laser diode is quite attractive for transmitting video signal. In this work signal to noise
ratio (S/N) higher than 20 dB is achieved in this work.

View Publication Preview PDF
Publication Date
Fri Sep 02 2022
Journal Name
Frontiers In Built Environment
Thermal analysis of horizontal earth-air heat exchangers in a subtropical climate: An experimental study
...Show More Authors

The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air veloci

... Show More
View Publication
Scopus (17)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Tue Mar 03 2026
Journal Name
Buildings
Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete
...Show More Authors

This research explored the performance of steel fiber concrete-filled stainless-steel tube columns stiffened with embedded carbon steel T-sections with various steel fiber ratios under biaxial bending conditions. A numerical parametric analysis was adopted, using finite element modeling with Abaqus CAE/2021 to evaluate the effects of the fiber ratio (ranging from 0% to 1.5%) on the load-bearing capacity and deflection behavior of columns. In addition, the compressive strength of concrete ranged between 45 and 65 MPa. An increase in the fiber ratio led to a substantial improvement in the ultimate load-bearing capacity (up to 24%), a reduction in deflection (of approximately 49%), and an improvement in column ductility, which were obt

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Sep 01 2022
Journal Name
International Journal Of Engineering Transactions C: Aspects
Axial Behavior of Concrete Filled-steel Tube Columns Reinforced with Steel Fibers
...Show More Authors

Concrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square c

... Show More
Scopus (6)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Case Studies In Thermal Engineering
Robust composite temperature control of electrical tube furnaces by using disturbance observer
...Show More Authors

As one type of resistance furnace, the electrical tube furnace (ETF) typically experiences input noise, measurement noise, system uncertainties, unmodeled dynamics and external disturbances, which significantly degrade its temperature control performance. To provide precise, and robust temperature tracking performance for the ETF, a robust composite control (RCC) method is proposed in this paper. The overall RCC method consists of four elements: First, the mathematical model of the ETF system is deduced, then a state feedback control (SFC) is constructed. Third, a novel disturbance observer (DO) is designed to estimate the lumped disturbance with one observer parameter. Moreover, the stability of the closed loop system including controller

... Show More
View Publication
Scopus (18)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Feb 04 2020
Journal Name
Applied Organometallic Chemistry
Phosphorus Schiff base ligand and its complexes: Experimental and theoretical investigations
...Show More Authors

A phosphorus‐containing Schiff base was prepared from bis{3‐[2‐(4‐amino‐1,5‐dimethyl‐2‐phenylpyrazol‐3‐ylideneamino)ethyl]indol‐1‐ylmethyl}phosphinic acid and paraformaldehyde as a novel antibacterial compound. The reaction of the Schiff base ligand with VO(IV), Ni(II), Co(II), Cu(II), Zn(II), Cd(II), Hg(II), Pd(II) and Pt(IV) led to binuclear species of metal complexes, depending on the ratio of metal ion and ligand. The ligand and its complexes were investigated using elemental analysis, Fourier transform infrared, 1H NMR, 13C NMR, UV–visible and mass spectra, thermogravimetric analysis, conductivity measurements and thermal analysis. The results showed that the S

... Show More
View Publication
Scopus (42)
Crossref (20)
Scopus Crossref
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Experimental Study For a Laminar Natural Convection Heat Transfer From an Isothermal Heated Square Plate With and Without Circular Hole
...Show More Authors

An experimental investigation of natural convection heat transfer from an isothermal horizontal,vertical and inclined heated square flat plates with and without circular hole, were carried out in two cases, perforated plates without an impermeable adiabatic hole "open core" and perforated plates with an impermeable adiabatic hole "closed core" by adiabatic plug. The experiments covered the laminar region with a range of Rayleih number of (1.11x106 ≤RaLo≤4.39x106 ), at Prandtle number (Pr=0.7). Practical experiments have been done with variable inclination angles from horizon (Ф=0o ,45o,90o,135oand 180o),facing upward (0o≤Ф<90o), and downward (90o
≤Ф<180o). The results showed that the temperature gradient increases whi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2026
Journal Name
Journal Of Trace Elements In Medicine And Biology
Synthesis, structural characterization, biological activity of trace metal complexes with a 2-aminobenzothiazole-derived schiff base: Experimental and docking studies
...Show More Authors

View Publication
Scopus Crossref