Preferred Language
Articles
/
GuYymp0BmraWrQ4d9lq7
NUMERICAL AND EXPERIMENTAL INVESTIGATIONOF STEAM FILM CONDENSATION ON A VERTICAL TUBE
...Show More Authors

 Film condensation of steam on a vertical tube is investigated numerically and experimentally,   in the present work. A mathematical model was set based on the basic conservation laws of mass   and energy, Nusselts analysis of film condensation, and empirical equations available in the   literature. Then, a simulation program in FORTRAN language was developed which simulates the   film condensation of steam on a vertical tube. A complete steam tables subprogram was also   developed and incorporated with the main program. The experimental work was carried out using a   steam condensation test bench. The inlet and outlet cooling water temperatures, steam temperature   and pressure, tube surface temperature at center, and cooling water flow rate are recorded during   each experimental test run. The inlet cooling water temperature, steam temperature, and cooling   water flow rate are used as an input for the numerical program, then the program calculates tube   surface temperature distribution, cooling water temperature distribution, local heat transfer rate,   local condensation heat transfer coefficient, condensate boundary layer thickness distribution, total   heat transfer rate, and average condensation heat transfer coefficient. The effect of various   parameters on the condensation heat transfer coefficient, such as steam temperature, steam-surface   temperature difference, and the presence of non-condensable gas were investigated and reported   graphically. It was found that increasing (steam-surface) temperature difference while keeping the   steam temperature constant results in an increase in condensate boundary layer thickness, which in   turn causes a decrease in condensation heat transfer coefficient. On the other hand, increasing steam   temperature and keeping the (steam-surface) temperature difference constant leads to an increase in   condensation heat transfer coefficient. In addition, the presence of non-condensable gas with   different concentrations was also investigated and it was shown that it causes a noticeable reduction   in the average condensation heat transfer coefficient. An equation for calculating average   condensation heat transfer coefficient on a vertical tube was also developed. The experimental data   obtained from the test runs were compared with numerical results and showed good agreement.   Thus, it can be concluded that the present computational program is suitable for simulating steam   condensation on a vertical tube. 

Crossref
View Publication
Publication Date
Thu Sep 01 2016
Journal Name
Applied Thermal Engineering
Solidification of a PCM with nanoparticles in triplex-tube thermal energy storage system
...Show More Authors

View Publication
Scopus (171)
Crossref (171)
Scopus Clarivate Crossref
Publication Date
Sat Apr 20 2019
Journal Name
Drug Invention Today
Preparation and evaluation of lornoxicam film-forming gel
...Show More Authors

Scopus (7)
Scopus
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Effect of in on the properties of AlSb thin film solar cell
...Show More Authors

View Publication
Scopus (17)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sat Oct 23 2021
Journal Name
Iraqi Journal Of Physics
Thin Film Dye Laser Based on BBQ Doped Poly (Methyl Meth-Acrylate)
...Show More Authors

This paper reports on the laser emission properties of the BBQ dye in poly (methyl meth-acrylate)(PMMA). This host material combines the advantages of an organic environment for dye with the thermoptical mechanical properties of an organic dye. A BBQ dye solid solution in PMMA polymer. A nitrogen laser in untuned laser cavity has pumped thin films. We developed the concentration and the thickness to get high efficiency. The laser efficiency had been increased from 7% at thickness 1.5 m to 16.5% at thickness 3.5m, and from 1% to 10% when concentration increased from 1x10-5M to 1x10-3 M

View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Proceeding Of Second Thermal And Fluids Engineering Conference
Solidification Enhancement in Triplex-Tube Latent Thermal Energy Storage System Using a Combination of Nanoparticles and Fins
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Journal Of Engineering 5263
COUPLED VERTICAL – TORSIONAL AND LATERAL FREE VIBRATION OF THIN-WALLED CURVED BEAM
...Show More Authors

This study is concerned with the derivation of differential equation of motion for the free coupled vertical – torsional and lateral vibration of opened thin-walled curved beams. The curved beam to be considered in this study is of isotropic opened thin – walled (I) section with equal top and bottom flanges. The derivation depends on Hamilton's principle which required finding the potential and kinetic energy of the curved beam section due to internal stresses and all types of movements (Vertical,Torsional and Lateral) .The effect of restrained warping displacement is also considered in this study. Three differential equations are derived for vertical, torsional and lateral movement .and approximate solutions are developed by using the

... Show More
Publication Date
Tue Oct 30 2018
Journal Name
Iraqi Journal Of Physics
Annealing effects on optical and structural properties of chromium oxide thin film deposited by PLD technique
...Show More Authors

Optical properties of chromium oxide (Cr2O3) thin films which were prepared by pulse laser deposition method, onto glass substrates. Different laser energy (500-900) mJ were used to obtain Cr2O3 thin films with thickness ranging from 177.3 to 372.4 nm were measured using Tolansky method. Then films were annealed at temperature equal to 300 °C. Absorption spectra were used to determine the absorption coefficient of the films, and the effects of the annealing temperature on the absorption coefficient were investigated. The absorption edge shifted to red range of wavelength, and the optical constants of Cr2O3 films increases as the annealing temperature increased to 300 °C. X-ray diffraction (XRD) study reveals that Cr2O3 thin films are a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Apr 23 2022
Journal Name
Research Journal Of Pharmacy And Technology
Effect of Natural/ Synthetic Polymers and Super disintegrants on the Formulation of Zafirlukast Fast Dissolving Film
...Show More Authors

Fast-dissolving films are one of the interested delivery systems for oral solid dosage forms to overcome swallowing difficulty for geriatric and pediatric patients. Zafirlukast (ZLK) is one of the most commonly used oral medication for treatment of asthmatic patients particularly mild to moderate cases. Oral fast dissolving films of ZLK were prepared using two different filming forming polymers, hydroxypropyl methylcellulose (HPMC) and sodium carboxymethyl cellulose (SCMC). Different concentrations of the 2 polymers were used to prepare 10 formulas. Other excipients were also added at various ratios to produce 10 different formulations. These were maltodextrin, crosspivodone, polyvinylpyrrolidone (PVP), and banana powder. In vitro c

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Thu Apr 20 2017
Journal Name
International Journal Of Science And Research (ijsr)
Effect of Different Sealer Systems on the Resistance to Vertical-Root-Fracture of Endodontically Treated Tooth
...Show More Authors

Abstract: An unfavorable complication of root canal is vertical root fracture. The aim of present study is to evaluate the vertical root fracture of treated teeth filled with gutta percha and Resilon obturating material using different sealers. Forty mandibular premolars used in the study. Canals randomly divided into four groups (n=10). Group-A eugenol-based (Endofill) sealer with gutta percha; GroupB epoxy-amine (AH Plus) sealer with gutta percha; Group-C resin-based (Real Seal) sealer with Resilon; or Group-D epoxide-based (Perma Evolution) sealer with gutta percha. Roots mounted vertically in cold cure acrylic blocks and subjected to vertical loading with a crosshead speed of 1mm ̸min. The point at which fracture of the roots occurred

... Show More
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
...Show More Authors

This study concerns a new type of heat exchangers, which is that of shell-and-double concentric tube heat exchangers. The case studies include both design calculations and performance calculations.

       The new heat exchanger design was conducted according to Kern method. The volumetric flow rates were 3.6 m3/h and 7.63 m3/h for the hot oil and water respectively. The experimental parameters studied were: temperature, flow rate of hot oil, flow rate of cold water and pressure drop.

A comparison was made for the theoretical and experimental results and it was found that the percentage error for the hot oil outlet temperature was (- 1.6%). The percentage

... Show More
View Publication