Preferred Language
Articles
/
GuYymp0BmraWrQ4d9lq7
NUMERICAL AND EXPERIMENTAL INVESTIGATIONOF STEAM FILM CONDENSATION ON A VERTICAL TUBE
...Show More Authors

 Film condensation of steam on a vertical tube is investigated numerically and experimentally,   in the present work. A mathematical model was set based on the basic conservation laws of mass   and energy, Nusselts analysis of film condensation, and empirical equations available in the   literature. Then, a simulation program in FORTRAN language was developed which simulates the   film condensation of steam on a vertical tube. A complete steam tables subprogram was also   developed and incorporated with the main program. The experimental work was carried out using a   steam condensation test bench. The inlet and outlet cooling water temperatures, steam temperature   and pressure, tube surface temperature at center, and cooling water flow rate are recorded during   each experimental test run. The inlet cooling water temperature, steam temperature, and cooling   water flow rate are used as an input for the numerical program, then the program calculates tube   surface temperature distribution, cooling water temperature distribution, local heat transfer rate,   local condensation heat transfer coefficient, condensate boundary layer thickness distribution, total   heat transfer rate, and average condensation heat transfer coefficient. The effect of various   parameters on the condensation heat transfer coefficient, such as steam temperature, steam-surface   temperature difference, and the presence of non-condensable gas were investigated and reported   graphically. It was found that increasing (steam-surface) temperature difference while keeping the   steam temperature constant results in an increase in condensate boundary layer thickness, which in   turn causes a decrease in condensation heat transfer coefficient. On the other hand, increasing steam   temperature and keeping the (steam-surface) temperature difference constant leads to an increase in   condensation heat transfer coefficient. In addition, the presence of non-condensable gas with   different concentrations was also investigated and it was shown that it causes a noticeable reduction   in the average condensation heat transfer coefficient. An equation for calculating average   condensation heat transfer coefficient on a vertical tube was also developed. The experimental data   obtained from the test runs were compared with numerical results and showed good agreement.   Thus, it can be concluded that the present computational program is suitable for simulating steam   condensation on a vertical tube. 

Crossref
View Publication
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
CFD Application on Shell and Double Concentric Tube Heat Exchanger
...Show More Authors

This work is concerned with the design and performance evaluation of a shell and double concentric tubes heat exchanger using Solid Works and ANSY (Computational Fluid Dynamics).

Computational fluid dynamics technique which is a computer-based analysis is used to simulate the heat exchanger involving fluid flow, heat transfer. CFD resolve the entire heat exchanger in discrete elements to find: (1) the temperature gradients, (2) pressure distribution, and (3) velocity vectors.  The RNG k-ε model of turbulence is used to determining the accurate results from CFD.

The heat exchanger design for this work consisted of a shell and eight double concentric tubes. The number of inlets are three and that of o

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Apr 07 2017
Journal Name
Marine Georesources & Geotechnology
Vertical vibration capacity of a single pile in dry sand
...Show More Authors

View Publication
Scopus (19)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Jul 01 2026
Journal Name
Journal Of Energy Storage
Novel multi-lobed tube designs for efficient latent thermal energy storage: A comprehensive study of single and dual-tube configurations
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Investigation for Simulation of Thermophysical Properties for Polypropylene 575 Polymer Melts in Single Screw Extruder
...Show More Authors

A numerical model for Polypropylene 575 polymer melts flow along the solid conveying screw of a single screw extruder under constant heat flux using ANSYS-FLUENT 17.2 software has been conducted. The model uses the thermophysical properties such as Viscosity, thermal conductivity, Specific heat and density of polypropylene 575 that measured as a function of temperature, and residence time data for process simulation. The numerical simulation using CFD models for single screw extruder and the polymer extrusion was analysed for parameters such as (thermal conductivity, specific heat, density and viscosity) reveals a high degree of similarity to experimental data measured. The most important outcome of this study is that geometrical, parame

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 31 2020
Journal Name
Buildings
Experimental and Numerical Study of Behaviour of Reinforced Masonry Walls with NSM CFRP Strips Subjected to Combined Loads
...Show More Authors

Near surface mounted (NSM) carbon fibers reinforced polymer (CFRP) reinforcement is one of the techniques for reinforcing masonry structures and is considered to provide significant advantages. This paper is composed of two parts. The first part presents the experimental study of brick masonry walls reinforced with NSM CFRP strips under combined shear-compression loads. Masonry walls have been tested under vertical compression, with different bed joint orientations 90° and 45° relative to the loading direction. Different reinforcement orientations were used including vertical, horizontal, and a combination of both sides of the wall. The second part of this paper comprises a numerical analysis of unreinforced brick masonry (URM) wa

... Show More
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Wed Oct 25 2017
Journal Name
European Journal Of Environmental And Civil Engineering
Effect of saturation on response of a single pile embedded in saturated sandy soil to vertical vibration
...Show More Authors

View Publication
Scopus (27)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2016
Journal Name
Arpn Journal Of Engineering And Applied Sciences
Numerical and experimental analysis of transient temperature and residual thermal stresses in friction stir welding of aluminum alloy 7020-T53
...Show More Authors

Scopus (2)
Scopus
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Effect of a Parked Car Orientation on a Temperature Distribution and Cooling Load Calculation: Experimental Study
...Show More Authors

When a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
EXPERIMENTAL OBSERVATIONS ON THE BEHAVIOR OF A PILED RAFT FOUNDATION
...Show More Authors

The piled raft is a geotechnical composite construction consisting of three elements: piles, raft and soil.
In the design of piled rafts, the load shared between the piles and the raft, and the piles are used up to a
load level that can be of the same order of magnitude as the bearing capacity of a comparable single
pile or even greater. Therefore, the piled raft foundation allows reduction of settlements in a very
economic way as compared to traditional foundation concepts.
This paper presents experimental study to investigate the behavior of piled raft system in sandy
soil. A small scale “prototype” model was tested in a sand box with load applied to the system through
a compression machine. The settlement was

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Wed Sep 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Essential Oils from Citrus By-Products Using Microwave Steam Distillation
...Show More Authors

The main objectives of this research is to extract essential oil from: orange ( citrus sinensis), lemon( citrus limon) and mandarin( citrus reticulata) peels by two methods: steam distillation (SD) and microwave assisted steam distillation (MASD), study the effect of extraction conditions (weight of the sample, extraction time, and microwave power, citrus peel type) on oil yield and compare the results of the two methods, the resulting essential oil was analyzed by Gas Chromatography (GC).

   Essential oils are highly concentrated substances used for their flavor and therapeutic or odoriferous properties, in a wide selection of products such as foods, medicines and cosmetics. Extracti

... Show More
View Publication Preview PDF