Preferred Language
Articles
/
GkJb7JsBMeyNPGM3MuLx
Preparation of Cross Linked PVA with MA, EDTA and a mixture of MA/EDTA for water uptake membranes at different pH
...Show More Authors

Poly (viny1 alcohol) (PVA) of 72000 g mol -1 molar mass was cross linked through cold cast esterification with different mol % of MA and EDTA (10 % , 20 % and 30 % ), and two different mol % mixture of MA l EDTA (20 %/5% and 20%/10% .

Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
Nitrification and urea hydrolysis in arid soil amended with different levels of bio-solid
...Show More Authors

Scopus
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Buckling and Pre Stressed Dynamics Analysis of Laminated Composite Plate with Different Boundary Conditions
...Show More Authors

Critical buckling and natural frequencies behavior of laminated composite thin plates subjected to in-plane uniform load is obtained using classical laminated plate theory (CLPT). Analytical investigation is presented using Ritz- method for eigenvalue problems of buckling load solutions for laminated symmetric and anti-symmetric, angle and cross ply composite plate with different elastic supports along its edges. Equation of motion of the plate was derived using principle of virtual work and solved using modified Fourier displacement function that satisfies general edge conditions. Various numerical investigation were studied to exhibit a convergence and accuracy of the present solution for considering some design parameters such as edge

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Synthesis and Characterization of New Polyimide by Curing Poly Acryloyl Chloride with Different Amides
...Show More Authors

The present work involved preparation of new substituted and unsubstituted and poly imides (1-17) using reaction of acryloyl chloride with different amides (aliphatic ,aromatic) in the presence of a suitable solvent and amount tri ethyl amine (Et3N) with heating – the structure confirmation of all polymers were proved using FT-IR,1H-NMR,C13NMR and UV spectroscopy ,thermal analysis (TG) for some polymers confirmed their thermal stabilities . Other physical properties including softening and melting points, PH and solubility of the polymers were also measured

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 27 2013
Journal Name
Engineering And Technology Journal
Total and Matric Suction in Unsaturated Soil with the Existence of Different Salts Content
...Show More Authors

Publication Date
Fri May 01 2009
Journal Name
Atti Della “fondazione Giorgio Ronchi”
Study of synthesis of nanocrystalline CdS thin film in PVA matrix by chemical bath deposition
...Show More Authors

SUMMARY. – Nanocrystalline thin fi lms of CdS are deposited on glass substrate by chemical bath deposited technique using polyvinyl alcohol (PVA) matrix solution. Crystallite size of the nanocrystalline films are determining from broading of X-ray diffraction lines and are found to vary from 0.33-0.52 nm, an increase of molarity the grain size decreases which turns increases the band gap. The band gap of nanocrystalline material is determined from the UV spectrograph. The absorption edge and absorption coefficient increases when the molarity increases and shifted towards the lower wavelength.

Preview PDF
Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Institutional Performance Assessment using a model of the European Foundation for Quality Management (EFQM) A case study at an organization
...Show More Authors

The study aims to use the European Excellence Model (EFQM) in assessing the institutional performance of the National Center for Administrative Development and Information Technology in order to determine the gap between the actual reality of the performance of the Center and the standards adopted in the model, in order to know the extent to which the Center seeks to achieve excellence in performance to improve the level of services provided and the adoption of methods Modern and contemporary management in the evaluation of its institutional performance.

The problem of the study was the absence of an institutional performance evaluation system at the centre whereby weaknesses (areas of improvement) and st

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 11 2019
Journal Name
Journal Of Global Pharma Technology
Using the Water Quality Index as a Powerful Tool to Assess the Water Quality for Drinking Purposes in Al-Salam, Western Region of Baghdad City, Iraq
...Show More Authors

Background: Tap waters play an important role in fulfilling the people needs for drinking and domestic purposes. Contaminate the tap water with different pollutants has become an issue of great concern for 90% of people who are depended on the tap water as the main source of drinking. Pollutants can make their way easily into the delivering pipes which suffer from the leaking resulting in decreasing the quality of water. Objective: Therefore, assess the water quality for drinking purpose by calculating the water quality index is an important tool to ascertain whether the water is suitable for human consumption or not. Methods: In the present work, the water quality of the Al-Salam, western region of Baghdad city, Iraq was investigated for 7

... Show More
View Publication
Scopus (5)
Scopus
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Study of NOx Emissions of S.I. Engine Fueled with Different Kinds of Hydrocarbon Fuels and Hydrogen
...Show More Authors

 

      Liquefied petroleum gas (LPG), Natural gas (NG) and hydrogen were used to operate spark ignition internal combustion engine Ricardo E6, to compare NOx emissions emitted from the engine, with that emitted from engine fueled with gasoline as a fuel.

      The study was done when engine operated at HUCR for gasoline, compared with its operation at HUCR for each fuel. Compression ratio, equivalence ratio and spark timing were studied at constant speed 25rps.

The results appeared that NOx concentrations will be at maximum value in the lean side near the stoichiometric ratio, and reduced with moving away from this ratio for mixture at both s

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Characterization of Poly (D,L-Lactide-Co-Glycolide) Microspheres for Controlled Release of KSL Peptide
...Show More Authors

The purpose of this research was to prepare, characterize, and evaluate the new antimicrobial peptide  KSL peptide encapsulated in poly(D,L-lactide-co-glycolide) (PLGA)composite microspheres. KSL was loaded in poly(acryloyl hydroxyethyl) starch (acHES) micropar-ticles, and then the peptide-containing microparticles were encapsulated in the PLGA matrix by a solvent extraction /evaporation method.

 KSL-loaded PLGA microspheres were also prepared without the starch hydrogel microparticle microspheres for comparison study. KSL peptide microspheres were characterized for drug content, surface morphology, microspheres size determination, polymers stability , in vitro microspheres degradation and in vitro release. KSL peptide

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and in-vitro Evaluation of Secnidazole as Periodontal In-situ Gel for Treatment of Periodontal Disease
...Show More Authors

This study aims to develop a thermosensitive mucoadhesive periodontal in situ gel of secnidazole for local release of drug for treatment of periodontitis, in order to increase the drug residence time and to increase patient compliance while lowering the side effects of the drug.

Cold method was used to prepare 30 formulas of secnidazole periodontal in situ gel, using different concentrations of thermosensitive polymers (poloxamer407 alone or in combination with poloxamer 188) and methyl cellulose (MC ) or hydroxypropyl methylcellulose (HPMC K4M )in different concentrations used as mucoadhesive polymer and the resultant formulations were subjected to several tests such as   gelation temperature GT, appearance and pH value. The fo

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (9)
Scopus Crossref