Pseudomonas aeruginosa is emerging opportunistic clinical pathogens. Clinical isolates of P. aeruginosaresist wide spectrum of antibiotics and form biofilm. The comparison study between clinical and environmental of P. aeruginosa in terms of biofilm formation and antibiotic resistance is very scanty. Thus, in current study microtiter plate technique was used to measure the biofilm formation by several clinical and environmental isolates. Moreover, the antibiotic susceptibility of these bacteria was evaluated by VITIK 2 techniques. The relationship between the antibiotic susceptibility and biofilm formation was evaluated for clinical and environmental isolates. Clinical and environmental isolates of P. aeruginosa produced a good amount of biofilm but the clinical isolates produced higher amount of biofilm as compared to environmental isolates. Resistance to antibiotics by clinical isolates was higher than resistance to antibiotics by environmental isolates and the minimum inhibition concentration (MIC) of most antibiotics to clinical isolates were higher than MIC against environmental isolates. Little relationship was observed between the biofilm formation and antibiotic resistance in case of clinical isolates, while no relationship was seen between the antibiotic susceptibility and biofilm formation. It can be concluded that the clinical isolates produced biofilm higher than environmental isolates. The relationship was seen only between the biofilm produced by clinical isolates and antibiotic susceptibility.
The aim of this research is to design and construct a semiconductor laser range finder
operating in the near infrared range for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of 0.904 mm wavelength with a beam expander,
and the receiver with its collecting optics. The characteristics of transmitter pulse width were 200ns and
threshold current 10 Amp. and maximum operating current 38 Amp. The repetition rate was set at 660 Hz
and maximum output power about 1 watt. The divergence of the beam was 0.268o. A special computer
code was used for optimum optical design and laser spot size analysis and for calculation of atmosphere
attenuation.
In Iraq, water shortages and drought, especially during the hot summer months, necessitates that municipal authorities adopt water reuse projects like reusing treated domestic wastewater for crop irrigation. This work gives the conceptual and basic design elements for the necessary steps of filtration, UV irradiation and chlorination to make such a wastewater fit for agricultural use. A typical rural community of 50,000 people is considered as an example case for which functionality and relative simplicity of the proposed designs are prime factors. The objectives are 1) to show what is required and 2) that the presented information may be utilized to embark on the following phases of detailed design and execution of such projects.
Increased downscaling of CMOS circuits with respect to feature size and threshold voltage has a result of dramatically increasing in leakage current. So, leakage power reduction is an important design issue for active and standby modes as long as the technology scaling increased. In this paper, a simultaneous active and standby energy optimization methodology is proposed for 22 nm sub-threshold CMOS circuits. In the first phase, we investigate the dual threshold voltage design for active energy per cycle minimization. A slack based genetic algorithm is proposed to find the optimal reverse body bias assignment to set of noncritical paths gates to ensure low active energy per cycle with the maximum allowable frequency at the optimal supply vo
... Show MoreRecently, the development of the field of biomedical engineering has led to a renewed interest in detection of several events. In this paper a new approach used to detect specific parameter and relations between three biomedical signals that used in clinical diagnosis. These include the phonocardiography (PCG), electrocardiography (ECG) and photoplethysmography (PPG) or sometimes it called the carotid pulse related to the position of electrode.
Comparisons between three cases (two normal cases and one abnormal case) are used to indicate the delay that may occurred due to the deficiency of the cardiac muscle or valve in an abnormal case.
The results shown that S1 and S2, first and second sound of the
... Show MoreThree types of metal carboxylates (Ho,Tb and Dy) stearates were LLSed as thennal stabi lizers for PVC. Infrared spectra (1500-1900
|
cm.1
were studied for PVC films stabilized with these metal
carboxylatcs. Two types of oxygen were round -containing products that were formed during the thermal degradation .On the other hand , the presence &nb
... Show MoreAccountancy unit is looked is upon as unit that established for the purpose achieve it goals and programmers for unlimited time. Unless otherwise take place such as liquation whether voluntary or mandatory. Thus going concern logic is considered to be the logical foundation witch the familiar accounting principles are based upon. The future of a Company real its financial statues and position and the extent of it ability to face events in future. Hence the success and continuity its activities depend on the extent of the company activity to generate profits. And its ability to retain appropriate liquidity to serve its debts.
Therefore financial statements of the company consider to be on
... Show MoreThe derivatives formed after the successive acetylation, esterification and nitration reactions to cholic, deoxycholic, and taurocholic acids were identified to be of the following general strucure: Colt, Where RI=NO3, OH, 0=, or CH3COO. R2=H, NO3, OH, 0-=, or CH3COO. R3=H, NO3,01-1, 0=, or CH3COO. R4=OH, NH(CH2)2S03Na, NH(CH2)2S03H, or OMe. By using U.V-visible and I.R spectrophotometry . The number of hydroxyl groups was determined, purity was checked from T.L.C, Most of these derivatives will find pharmaceutical application.