Preferred Language
Articles
/
GhbQuYsBVTCNdQwCH9hc
Field treatment of three wheat varieties with Trichoderma harzianum bioagent to control Anguina tritici
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Sun May 01 2016
Journal Name
Journal Of Engineering
Three-Dimensional Finite Element Simulation of the Buried Pipe Problem in Geogrid Reinforced Soil
...Show More Authors

Buried pipeline systems are commonly used to transport water, sewage, natural oil/gas and other materials. The beneficial of using geogrid reinforcement is to increase the bearing capacity of the soil and decrease the load transfer to the underground structures.

This paper deals with simulation of the buried pipe problem numerically by finite elements method using the newest version of PLAXIS-3D software. Rajkumar and Ilamaruthi's study, 2008 has been selected to be reanalyzed as 3D problem because it is containing all the properties needed by the program such as the modulus of elasticity, Poisson's ratio, angle of internal friction. It was found that the results

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Force decay of orthodontic elastomeric chains by using three different mechanisms simulating canine retraction
...Show More Authors

Background: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different bran

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 25 2018
Journal Name
Biomedical And Pharmacology Journal
Comparing the Impact Strength and Transverse Flexure Strength of Three Different Dentures Base Materials
...Show More Authors

View Publication
Crossref (8)
Crossref
Publication Date
Tue Dec 20 2022
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
FIRST RECORD OF TWO DIPLECTANID MONOGENOIDS FROM THREE SPARID FISHES IN IRAQI MARINE WATERS
...Show More Authors

Parasitological examination of gills of three species of sparid fishes in the territorial waters of Iraq was performed, two diplectanid monogenoids were isolated and described; Lamellodiscus indicus Tripathi, 1959 from both Haffara seabream Rhabdosargus haffara (Forsskål, 1775) and Goldline seabream R. sarba (Forsskål, 1775) and Protolamellodiscus senilobatus Kritsky, Jiménez-Ruiz and Sey, 2000 from King soldierbream Argyrops spinifer (Forsskål, 1775). The record of the parasites is considered new to the parasite fauna of Iraq. The redescription of L. indicus for the first time which is collected from a new distribution area (Arabian Gulf). R. haffara is considered a new host record .

View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Solid State Technology
Access Control Security Review: Concepts and Models
...Show More Authors

HS Saeed, SS Abdul-Jabbar, SG Mohammed, EA Abed, HS Ibrahem, Solid State Technology, 2020

View Publication
Publication Date
Tue Jan 01 2013
Journal Name
International Journal Of Innovation, Management And Technology
Intelligent Magneto-Rheological Fluid Directional Control Valve
...Show More Authors

There are many configurations of directional control valve. Directional control valve has complex construction, such as moving spool to control the direction of actuator and desired speed. Magneto-rheological (MR) fluid is one of controllable fluids. Utilizing the MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This paper presents the design of multi configuration MR directional control valve. The construction and the principle of work of the valve are presented. The experiment was conducted to show the working principle of the valve functionally. The valve worked proportionally to control the direction and speed of hydra

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Plant Archives
Schistosomiasis vector control using cucumis melo plantextractswithbioassayexperiment
...Show More Authors

he aim of this study is to get a plant extracts to use it as molluscicides to control the snail vector of Schistosomiasis andfinely control the disease. Laboratory study was performed to compare the molluscicidal activity of leaves and stems extractsof Cucumis melo against Bulinus truncatus snail. The snail B. truncatus was exposed to a serial concentrations of leaves andstems extracts (4000ppm, 5000ppm) in this work. Different effects of the extracts to the snail B. truncatus were recorded.These effects includes death, escaping and imbalance of snail behavior. 96hr-LD50 values of leaves extracts were calculatedfor the doses 4000 and 5000ppm as (76 and 37%) respectively while for stems were (105 and 47%) respectively. We found thatthe snail

... Show More
View Publication
Scopus
Publication Date
Mon Dec 26 2011
Journal Name
Journal Of Intelligent Material Systems And Structures
Design and modeling magnetorheological directional control valve
...Show More Authors

Directional control valves are designed to control direction of flow, while actuators maintain required speeds and precise positions. Magnetorheological (MR) fluid is a controllable fluid. Utilizing the MR fluid properties, direct interface between magnetic fields and fluid power is possible, without the need for mechanical moving parts like spools. This study proposes a design of a four-way three-position MR directional control valve, presents a method of building, and explains the working principle of the valve. An analysis of the design and finite elements using finite element method of magnetism (FEMM) software was performed on each valve. The magnetic circuit of the MR valve was analyzed and the performance was simulated. The

... Show More
View Publication
Scopus (31)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Solid State Technology
Access Control Security Review: Concepts and Models
...Show More Authors

Publication Date
Tue Mar 04 2008
Journal Name
Journal Of Baghdad College Of Dentistry
Twelve months clinical comparison between modified Widman flap with or without enamel matrix derivative for the treatment of infrabony defects
...Show More Authors