Preferred Language
Articles
/
GWFcKZkBdMdGkNqjICOK
Noise Modeling and Removal from Electrocardiogram Signals: A Study Using Wavelet Transform with Graphical User Interface
...Show More Authors

The electrocardiogram (ECG) is the recording of the electrical potential of the heart versus time. The analysis of ECG signals has been widely used in cardiac pathology to detect heart disease. The ECGs are non-stationary signals which are often contaminated by different types of noises from different sources. In this study, simulated noise models were proposed for the power-line interference (PLI), electromyogram (EMG) noise, base line wander (BW), white Gaussian noise (WGN) and composite noise. For suppressing noises and extracting the efficient morphology of an ECG signal, various processing techniques have been recently proposed. In this paper, wavelet transform (WT) is performed for noisy ECG signals. The graphical user interface (GUI) system is developed for visual representation and adaptive enhancement on noise modeling in ECG-based signal processing. Percentage root mean square difference (PRD) was measured between the modeled noisy signals and the samples of the original ECG. Moreover, cross correlation (XCorr) and root mean square error (RMSE) were performed between the noisy ECG signals and the denoised ones which resulted from WT denoising technique initially to evaluate the effectiveness of the WT denoising technique. The results show that the WT was successfully removed different types of proposed models of noises. The PRD was reasonable and are within the acceptable range, which is less than 50%, with 17% for BW and 47% for PLI indicating that the models and methods used for prediction are ideal for high precision signal applications. This study will help medical doctors, clinicians, physicians, and technicians to eliminate different types of noise.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Ecological Engineering
Dual Application of Al-Kheriat of Removal of Arsenic from Aqueous Solution and Acting as Rodenticide
...Show More Authors

Arsenic is a prevalent and pervasive environmental contaminant with varied amounts in drinking water. Arsenic exposure causes cancer, cardiovascular, liver, nerve, and ophthalmic diseases. The current study aimed to find the best conditions for eliminating arsenic from simulated wastewater and their effect on biomarkers of hepatic in mice. Adsorption tests including pH, contact duration, Al-kheriat dosage, and arsenic concentrations were evaluated. Seventy-two healthy albino mice (male) were accidentally allocated into nine groups (n = 8), the first group was considered as healthy control, the second group (AL-Kheriat), and other groups received AL-Kheriat and arsenic 25, 50, 75, 100, 125, 150 and 175 mg/kg, respectively. Next 10 days, the

... Show More
Crossref (3)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Desalination And Water Treatment
Removal of toxic dye (Rhodamine B) from aqueous solutions by natural smectite (SMC) and SMC-nanoTiO2
...Show More Authors

View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2000
Journal Name
Al-rafidain Collage Conference
The Modification of Median Filter to use as noise reduction procedure
...Show More Authors

Publication Date
Thu Mar 02 2023
Journal Name
East European Journal Of Physics
Evaluation of the Influence of Body Mass Index and Signal-to-Noise Ratio on the PET/CT Image Quality in Iraqi Patients with Liver Cancer
...Show More Authors

Image quality has been estimated and predicted using the signal to noise ratio (SNR). The purpose of this study is to investigate the relationships between body mass index (BMI) and SNR measurements in PET imaging using patient studies with liver cancer. Three groups of 59 patients (24 males and 35 females) were divided according to BMI. After intravenous injection of 0.1 mCi of 18F-FDG per kilogram of body weight, PET emission scans were acquired for (1, 1.5, and 3) min/bed position according to the weight of patient. Because liver is an organ of homogenous metabolism, five region of interest (ROI) were made at the same location, five successive slices of the PET/CT scans to determine the mean uptake (signal) values and its standard deviat

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Regression Modeling of EDM Process for AISI D2 Tool Steel with RSM
...Show More Authors

In this paper, Response Surface Method (RSM) is utilized to carry out an investigation of the impact of input parameters: electrode type (E.T.) [Gr, Cu and CuW], pulse duration of current (Ip), pulse duration on time (Ton), and pulse duration off time (Toff) on the surface finish in EDM operation. To approximate and concentrate the suggested second- order regression model is generally accepted for Surface Roughness Ra, a Central Composite Design (CCD) is utilized for evaluating the model constant coefficients of the input parameters on Surface Roughness (Ra). Examinations were performed on AISI D2 tool steel. The important coefficients are gotten by achieving successfully an Analysis of V

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 02 2025
Journal Name
Engineering, Technology & Applied Science Research
A Numerical Study of Concrete Composite Circular Columns encased with GFRP I-Section using the Finite Element Method
...Show More Authors

This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Results In Nonlinear Analysis
Numerical solutions for the time fractional Black-Scholes model governing European option by using double integral transform decomposition method
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Computational Condensed Matter
Computational modeling study on the physical properties of Pd doped BaTiO3 perovskite
...Show More Authors

This contribution investigates structural, electronic, and optical properties of cubic barium titanate (BaTiO3) perovskites using first-principles calculations of density functional theory (DFT). Generalized gradient approximations (GGA) alongside with PW91 functional have been implemented for the exchange–correlation potential. The obtained results display that BaTiO3 exhibits a band gap of 3.21 eV which agrees well with the previously experimental and theoretical literature. Interestingly, our results explore that when replacing Pd atom with Ba and Ti atoms at 0.125 content a clear decrease in the electronic band gap of 1.052 and 1.090 eV located within the visible range of electromagnetic wavelengths (EMW). Optical parameters such as a

... Show More
View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Fri Feb 14 2020
Journal Name
Progress In Industrial Ecology, An International Journal
3D image reconstruction from its 2D projection - a simulation study
...Show More Authors

A simulation study of using 2D tomography to reconstruction a 3D object is presented. The 2D Radon transform is used to create a 2D projection for each slice of the 3D object at different heights. The 2D back-projection and the Fourier slice theorem methods are used to reconstruction each 2D projection slice of the 3D object. The results showed the ability of the Fourier slice theorem method to reconstruct the general shape of the body with its internal structure, unlike the 2D Radon method, which was able to reconstruct the general shape of the body only because of the blurring artefact, Beside that the Fourier slice theorem could not remove all blurring artefact, therefore, this research, suggested the threshold technique to eliminate the

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Cleaner Production
A study of biogas production from date palm fruit wastes
...Show More Authors

View Publication
Scopus (49)
Crossref (45)
Scopus Clarivate Crossref