Preferred Language
Articles
/
GWFcKZkBdMdGkNqjICOK
Noise Modeling and Removal from Electrocardiogram Signals: A Study Using Wavelet Transform with Graphical User Interface
...Show More Authors

The electrocardiogram (ECG) is the recording of the electrical potential of the heart versus time. The analysis of ECG signals has been widely used in cardiac pathology to detect heart disease. The ECGs are non-stationary signals which are often contaminated by different types of noises from different sources. In this study, simulated noise models were proposed for the power-line interference (PLI), electromyogram (EMG) noise, base line wander (BW), white Gaussian noise (WGN) and composite noise. For suppressing noises and extracting the efficient morphology of an ECG signal, various processing techniques have been recently proposed. In this paper, wavelet transform (WT) is performed for noisy ECG signals. The graphical user interface (GUI) system is developed for visual representation and adaptive enhancement on noise modeling in ECG-based signal processing. Percentage root mean square difference (PRD) was measured between the modeled noisy signals and the samples of the original ECG. Moreover, cross correlation (XCorr) and root mean square error (RMSE) were performed between the noisy ECG signals and the denoised ones which resulted from WT denoising technique initially to evaluate the effectiveness of the WT denoising technique. The results show that the WT was successfully removed different types of proposed models of noises. The PRD was reasonable and are within the acceptable range, which is less than 50%, with 17% for BW and 47% for PLI indicating that the models and methods used for prediction are ideal for high precision signal applications. This study will help medical doctors, clinicians, physicians, and technicians to eliminate different types of noise.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
Evaluating Windows Vista user account security
...Show More Authors

In the current Windows version (Vista), as in all previous versions, creating a user account without setting a password is possible. For a personal PC this might be without too much risk, although it is not recommended, even by Microsoft itself. However, for business computers it is necessary to restrict access to the computers, starting with defining a different password for every user account. For the earlier versions of Windows, a lot of resources can be found giving advice how to construct passwords of user accounts. In some extent they contain remarks concerning the suitability of their solution for Windows Vista. But all these resources are not very precise about what kind of passwords the user must use. To assess the protection of pa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2015
Journal Name
International Journal Of Current Microbiology And Applied Sciences
Quantitative identification of phosphate using X-ray diffraction and Fourier transform infrared (FTIR) spectroscopy
...Show More Authors

Inthisstudy,FourierTransformInfraredSpectrophotometry(FTIR),XRay Diffraction(XRD)andlossonignition(LOI),comparativelyemployedtoprovideaquick,relativelyinexpensiveandefficientmethodforidentifyingandquantifyingcalcitecontentofphosphateoresamplestakenfromAkashatsiteinIraq.Acomprehensivespectroscopicstudyofphosphate-calcitesystemwasreportedfirstintheMid-IRspectra(4004000cm-1)usingShimadzuIRAffinity-1,fordifferentcutsofphosphatefieldgradeswithsamplesbeneficiatedusingcalcinationandleachingwithorganicacidatdifferenttemperatures.Thenusingtheresultedspectratocreateacalibrationcurverelatesmaterialconcentrationstotheintensity(peaks)ofFTIRabsorbanceandappliesthiscalibrationtospecifyphosphate-calcitecontentinIraqicalcareousphosphateore.Theirpeakswereass

... Show More
Publication Date
Tue Mar 01 2022
Journal Name
International Journal Of Nonlinear Analysis And Applications
The suggested threshold to reduce data noise for a factorial experiment
...Show More Authors

In this research, a factorial experiment (4*4) was studied, applied in a completely random block design, with a size of observations, where the design of experiments is used to study the effect of transactions on experimental units and thus obtain data representing experiment observations that The difference in the application of these transactions under different environmental and experimental conditions It causes noise that affects the observation value and thus an increase in the mean square error of the experiment, and to reduce this noise, multiple wavelet reduction was used as a filter for the observations by suggesting an improved threshold that takes into account the different transformation levels based on the logarithm of the b

... Show More
Publication Date
Fri Mar 31 2017
Journal Name
Journal Of Engineering
Comparative Study between Nanofiltration and Reverse Osmosis Membranes for the Removal of Heavy Metals from Electroplating Wastewater
...Show More Authors

The present work aimed to study the efficiency of nanofiltration (NF) and reverseosmosis (RO) process for water recovery from electroplating wastewater and study the factors affecting the performance of two membrane processes. Nanofiltration and reverse osmosismembranes are made from polyamide as spiral wound module. The inorganic materials ZnCl 2 CuCl2 .2H2O, NiCl.2.6H2O and CrCl3.6H2O were used as feed solutions. The operating parametersstudied were: operating time, feed concentrations for heavy metal ions, operating pressure, feed flow rate, feed temperature and feed pH. The experimental results showed, the permeateconcentration increased and water flux decreased with increase in time from 0 to 70 min. Thepermeate concentrations incre

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2017
Journal Name
Journal Of Engineering
Comparative Study between Nanofiltration and Reverse Osmosis Membranes for the Removal of Heavy Metals from Electroplating Wastewater
...Show More Authors

The present work aimed to study the efficiency of nanofiltration (NF) and reverse osmosis (RO) process for water recovery from electroplating wastewater and study the factors affecting the performance of two membrane processes. Nanofiltration and reverse osmosis membranes are made from polyamide as spiral wound module. The inorganic materials ZnCl2, CuCl2.2H2O, NiCl2.6H2O and CrCl3.6H2O were used as feed solutions. The operating parameters studied were: operating time, feed concentrations for heavy metal ions, operating pressure, feed flow rate, feed temperature and feed pH. The experimental results showed, the permeate concentration increased and water flux decreased with increase in time from 0 to 70 min. The permeate concentrations incre

... Show More
Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Removal of Dissolved Organic Compounds and Contaminants from Wastewater of a Petroleum Refinery by Ion Exchange
...Show More Authors

The efficient removal of dissolved organic compounds (DOC) from wastewater has become a major environmental concern because of its high toxicity even at low concentrations. Therefore, a technique was needed to reduce these pollutants. Ion exchange technology (IE) was used with AmberliteTM IR120 Na, AmberliteTM IR96RF, and AmberliteTM IR402, firstly by using anion and mixed bed system, where the following variables are investigated for the process of adsorption: The height of the bed in column (8,10 and 14 cm), different concentrations of (DOC) content at constant flow rate. The use of an ion exchanger unit (continuous system) with three columns (cation, anion, and mixed bed) was studied.

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Journal Of Information Hiding And Multimedia Signal Processing
Upscale Gray Image using Mixing Transform Generation based on Tensor Product
...Show More Authors

The increased size of grayscale images or upscale plays a central role in various fields such as medicine, satellite imagery, and photography. This paper presents a technique for improving upscaling gray images using a new mixing wavelet generation by tensor product. The proposed technique employs a multi-resolution analysis provided by a new mixing wavelet transform algorithm to decompose the input image into different frequency components. After processing, the low-resolution input image is effectively transformed into a higher-resolution representation by adding a zeroes matrix. Discrete wavelets transform (Daubechies wavelet Haar) as a 2D matrix is used but is mixed using tensor product with another wavelet matrix’s size. MATLAB R2021

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Multi-Focus Image Fusion Based on Pixel Significance Using Counterlet Transform
...Show More Authors

Abstract

 The objective of image fusion is to merge multiple sources of images together in such a way that the final representation contains higher amount of useful information than any input one.. In this paper, a weighted average fusion method is proposed. It depends on using weights that are extracted from source images using counterlet transform. The extraction method is done by making the approximated transformed coefficients equal to zero, then taking the inverse counterlet transform to get the details of the images to be fused. The performance of the proposed algorithm has been verified on several grey scale and color test  images, and compared with some present methods.

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Modeling and Kinetics of Removing Metal Ions from Industrial Wastewater
...Show More Authors

The study's objective is to produce Nano Graphene Oxide (GO) before using it for batch adsorption to remove heavy metals (Cadmium Cd+2, Nickel Ni+2, and Vanadium V+5) ions from industrial wastewater. The temperature effect (20-50) °C and initial concentration effect (100-800) mg L-1 on the adsorption process were studied. A simulation aqueous solution of the ions was used to identify the adsorption isotherms, and after the experimental data was collected, the sorption process was studied kinetically and thermodynamically. The Langmuir, Freundlich, and Temkin isotherm models were used to fit the data. The results showed that Cd, Ni, and V ions on the GO adsorbing surface matched the Langmuir model with correlation coefficients (R2)

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Modeling and Kinetics of Removing Metal Ions from Industrial Wastewater
...Show More Authors

The study's objective is to produce Nano Graphene Oxide (GO) before using it for batch adsorption to remove heavy metals (Cadmium Cd+2, Nickel Ni+2, and Vanadium V+5) ions from industrial wastewater. The temperature effect (20-50) °C and initial concentration effect (100-800) mg L-1 on the adsorption process were studied. A simulation aqueous solution of the ions was used to identify the adsorption isotherms, and after the experimental data was collected, the sorption process was studied kinetically and thermodynamically. The Langmuir, Freundlich, and Temkin isotherm models were used to fit the data. The results showed that Cd, Ni, and V ions on the GO adsorbing surface matched the Langmuir mo

... Show More
View Publication Preview PDF
Crossref (6)
Crossref