Background and Aim: due to the rapid growth of data communication and multimedia system applications, security becomes a critical issue in the communication and storage of images. This study aims to improve encryption and decryption for various types of images by decreasing time consumption and strengthening security. Methodology: An algorithm is proposed for encrypting images based on the Carlisle Adams and Stafford Tavares CAST block cipher algorithm with 3D and 2D logistic maps. A chaotic function that increases the randomness in the encrypted data and images, thereby breaking the relation sequence through the encryption procedure, is introduced. The time is decreased by using three secure and private S-Boxes rather than using six S-Boxes, as in the traditional method. Moreover, the CAST encryption algorithm was modified to be used on the private keys and substitution stage (S-Boxes), with the keys and S-Boxes of the encryption algorithm being generated according to the 2D and 3D chaotic map functions. The proposed system passed all evaluation criteria, including (MSE, PSNR, EQ, MD, SC, NC, AD, SNR, SIM, MAE, Time, CC, Entropy, and histograms). Results: Moreover, the results also illustrate that the created S-Boxes passed all evaluation criteria; compared with the results of the traditional method that was used in creating S-Box, the proposed method achieved better results than other methods used in the other works. The proposed solution improves the entropy which is between (7.991–7.999), reduces the processing time which is between (0.5–11 s/Images), and improves NCPR, which is between (0.991–1). Conclusions: The proposed solution focuses on reducing the total processing time for encryption and decryption and improving transmission security. Finally, this solution provides a fast security system for surgical telepresence with secure real-time communication. The complexity of this work needs to know the S-Box creation method used, the chaotic method, the values of the chaotic parameters, and which of these methods was used in the encryption process.
The Na Bop-Pu Sap Pb-Zn ore bodies represent a typical vein-type lead-zinc deposit situated in the Cho Don area and are currently being extracted for their lead and zinc resources. This deposit is characterized by its significant scale and quality and is considered one of the prominent lead-zinc deposits in the Cho Don area. Despite its significance, this deposit has not received adequate attention, resulting in limited knowledge of its geology, mineralization, and deposit genesis model. To address this knowledge gap, our study utilized several methodologies, including field surveying, ore mineral analysis under a microscope, and S and Pb isotopic geochemistry. By employing these approaches, we were able to obtain specific insights
... Show MoreThe spread of novel coronavirus disease (COVID-19) has resulted in chaos around the globe. The infected cases are still increasing, with many countries still showing a trend of growing daily cases. To forecast the trend of active cases, a mathematical model, namely the SIR model was used, to visualize the spread of COVID-19. For this article, the forecast of the spread of the virus in Malaysia has been made, assuming that all Malaysian will eventually be susceptible. With no vaccine and antiviral drug currently developed, the visualization of how the peak of infection (namely flattening the curve) can be reduced to minimize the effect of COVID-19 disease. For Malaysians, let’s ensure to follow the rules and obey the SOP to lower the
The developments in forensic DNA technology have led us to perform this study in Iraqi population as reference database of autosomal Short Tandem Repeat (aSTR) DNA markers . A total of 120 unrelated individuals from Wasit province were analyzed at 15 STR DNA markers. Allele frequencies of DNA typing loci included in the AmpFlSTR1 IdentifilerTM PCR Amplification Kit panel from Applied Biosystems (D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820, TH01, TPOX, CSF1PO, D19S433, D2S1338, D16S539) and several forensic efficiency statistical parameters were estimated from all the sample. the combined Matching Probability (CMP) using the 15 STR genetic loci in Iraqi population was estimated at 1 in 2.08286E-18 and the Combined
... Show MoreThis paper has investigated experimentally the dynamic buckling behavior of AISI 303 stainless steel Aluminized and as received long columns. These columns, hot-dip aluminized and as received, are tested under dynamic buckling, 22 specimens, without aluminizing (type 1), and 50 specimens, with hot-dip aluminizing at different aluminizing conditions of dipping temperature and dipping time (type 2), are tested under dynamic compression loading and under dynamic combined loading (compression and bending) by using a rotating buckling test machine. The experimental results are compared with Perry Robertson interaction formula that used for long columns. Greenhill formula is used to get a mathematical model that descripts the buckling behavior
... Show MoreTwo homopolymeric and three copolymeric additives for base oil were synthesized using octyl acrylate (OA) and tert-butyl acrylamide (TBA) monomers. The two additives named P1 and P2 are the homopolymers of TBA and OA, respectively, whereas copolymeric additives named Co1, Co2, and Co3 were synthesized by varying the ratios of TBA:OA as 1:3, 3:1 and 1:1, respectively. The prepared polymers were characterized by Fourier Transform Infrared (FTIR). Based on the solubility of synthesized polymers in base oil and reactivity ratios of TBA/OA copolymer (0.222, 0.434) calculated by Fineman-Ross method, P2, Co1, Co2 and Co3 were selected to evaluate their performance as pour point depressant (PPD), viscosity improver (VII), and anticorrosion addit
... Show MoreContinuous turbidimetric analysis (CTA) for a distinctive analytical application by employing a homemade analyser (NAG Dual & Solo 0-180°) which contained two consecutive detection zones (measuring cells 1 & 2) is described. The analyser works based on light-emitting diodes as a light source and a set of solar cells as a light detector for turbidity measurements without needing further fibres or lenses. Formation of a turbid precipitated product with yellow colour due to the reaction between the warfarin and the precipitation reagent (Potassium dichromate) is what the developed method is based on. The CTA method was applied to determine the warfarin in pure form and pharmaceu
Continuous turbidimetric analysis (CTA) for a distinctive analytical application by employing a homemade analyser (NAG Dual & Solo 0-180°) which contained two consecutive detection zones (measuring cells 1 & 2) is described. The analyser works based on light-emitting diodes as a light source and a set of solar cells as a light detector for turbidity measurements without needing further fibres or lenses. Formation of a turbid precipitated product with yellow colour due to the reaction between the warfarin and the precipitation reagent (Potassium dichromate) is what the developed method is based on. The CTA method was applied to determine the warfarin in pure form and pharmaceu
تهدف هذه الدراسة إلى بحث ظاهرة الاغتراب في رواية " ديك الفداء " لايلي عامير ، لأن هذه الظاهرة تبدو أكثر وضوحا في هذه الرواية ، وتمثل تیارا مسيطرة على معطياتها واتجاهاتها الفكرية والفنية، خاصة أن الكاتب استطاع أن يجسد هذه الظاهرة المحورية تجسيدا فنيا متميزا ، وكشف عن طبيعة العلاقة بين عالم الواقع وعالم الحلم لدى الشخصيات، وعما تتسم به من تناقض و تعارض وتصادم و شعور بالإحباط والضياع والاغتراب. وقد اشتملت ال
... Show MoreFunctionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p
... Show More