Preferred Language
Articles
/
GBfHYo8BVTCNdQwCCXXY
0.1 Second versus 0.2 Second pulse duration of Frequency Doubled Nd: YAG Laser in treatment of Clinically Significant Diabetic Maculopathy.
...Show More Authors

Background: clinically significant macular edema (CSME) is the commonest cause of visual loss in patients with diabetes mellitus and laser focal photocoagulation is the golden standard for treating it. Patients and Methods: A frequency doubled Nd: YAG laser was used to treat all eyes included in this study with diabetic maculopathy. Thirty eyes of three insulin dependent and twenty six non insulin dependent diabetic Iraqi patients were included. The study involved twenty six males, three females and followed for one year. Their ages were ranging between 36- 59 years, all of them from patients attending ophthalmic out-patient department in the medical city in the period between January 2005 and June 2006. Eyes divided in to two groups (fifteen eyes in each group) and the disease severity was taken into account. The first group treated with 0.1 second and second group with 0.2 second pulse duration. Results: In group (1) improvement of V.A occurred in 19.99% (Statistically significant) and 60% (Statistically significant) in group (2). There was stabilization 80% (Statistically insignificant) in group (1) and 33.33% Stabilization (Statistically significant) in group (2), while worsening only in group (2) 6.67% (Statistically insignificant). Conclusion: The frequency doubled Nd:YAG laser is effective in controlling diabetic macular oedema when applied in focal treatment. The setting of 100µm 0.2sec., pulse exposure time show more improvement in V.A. than 100µm 0.1sec

Publication Date
Fri Dec 01 2017
Journal Name
The Iraqi Postgraduate Medical Journal
Extensive Versus Traditional Phototherapy in Treatment of Neonatal Jaundice
...Show More Authors

View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Iraqi Journal Of Hematology
Provisional diagnosis of clinically significant hemoglobinopathies and decision on suitability for marriage as part of the premarital screening program in Iraq: Iraqi Society of Hematology Guidelines
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Nov 06 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Nurse–Midwives' Knowledge and Practices toward Second Stage of Labor
...Show More Authors

Objective: To assess the nurses-midwives' knowledge and practices regarding the management of second stage
of labor and to find out the association between their knowledge and practices and socio-demographic
characteristics and working years and experience.
Methodology: A descriptive study was carried out from March 22nd
, 2008 through 30th June, 2008. A purposive
sample of (75) Nurse-Midwives which was selected from (6) hospitals. A questionnaire was comprised of two
parts: (socio-demographic characteristics and the assessment tool for Nurse-Midwives' knowledge and health
practices performed by them). The questionnaire validity was determined by experts and its reliability was
determined through a pilot study. Th

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of King Saud University - Science
Three iterative methods for solving second order nonlinear ODEs arising in physics
...Show More Authors

View Publication
Crossref (18)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Synthesis AgO Nanoparticles by Nd:Yag Laser with Different Pulse Energies
...Show More Authors

     One technique used to prepare nanoparticles material is Pulsed Laser Ablation in Liquid (PLAL), Silver Oxide nanoparticles (AgO) were prepared by using  this technique, where silver target was submerged in ultra-pure water (UPW)  at room temperature after that Nd:Yag laser which characteristics by 1064 nm wavelength, Q-switched, and 6ns pulse duration was used to irradiated silver target. This preparation method was used to study the effects of laser irradiation on Nanoparticles synthesized by used varying laser pulse energy 1000 mJ, 500 mJ, and 100 mJ, with 500 pulses each time on the particle size. Nanoparticles are characterized using XRD, SEM, AFM, and UV-Visible spectroscopy. All the structural peaks determined by the XRD

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Apr 07 2013
Journal Name
Journal Of Educational And Psychological Researches
Effectiveness of enrichment activities through using software program for second graders in Conversation article
...Show More Authors

Today we are witnessing huge scientific and technical progress so we need more skills and methods of thinking that needs to be acquired by the teacher, as the importance of computers in education  there are  many teachers  suffering  of the difficulty in teaching for pupils . researchers tried to  find a good suitable way with the technological  interests for now which represent by  computer design software and the introduction of enrichment activities in the curriculum because it is one of a contemporary trends for the development of the Arabic language with various levels of education and knowing if this program has negative or positive impact.

So&nbsp

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Educational And Psychological Researches
The Effect of Caroll’s Pattern on the Second Intermediate Class Pupils' Achievement in Geography
...Show More Authors

The present study aims at finding out the (effect of the Caroll’s pattern on the second intermediate class pupils' achievement in geography)

The partial experimental design of two groups, experimental and control, with pre-post tests is used. The sample is represented in (74) female pupils. The sample is divided into two groups (38) experimental group and (36) control one. The sample is selected from first intermediate  class pupils    ( Am Salama Secondary School for girls) \ Baghdad\ Al-karkh-1, for academic year 2015-2016.

The researcher has equalized the two groups in several variables: the previous achievement tests, intelligence, age in months, the scor

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Second Order Sliding Mode Controller Design for Pneumatic Artificial Muscle
...Show More Authors

In this paper, first and second order sliding mode controllers are designed for a single link robotic arm actuated by two Pneumatic Artificial Muscles (PAMs). A new mathematical model for the arm has been developed based on the model of large scale pneumatic muscle actuator model. Uncertainty in parameters has been presented and tested for the two controllers. The simulation results of the second-order sliding mode controller proves to have a low tracking error and chattering effect as compared to the first order one. The verification has been done by using MATLAB and Simulink software.

 

View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Solution of Second Kind Volterra Integral Equations Using Non-Polynomial Spline Functions
...Show More Authors

In this paper we use non-polynomial spline functions to develop numerical methods to approximate the solution of 2nd kind Volterra integral equations. Numerical examples are presented to illustrate the applications of these method, and to compare the computed results with other known methods.

View Publication Preview PDF
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Urinary Tract Stones Fragmentation using (2100 nm) Holmium: YAG Laser: (In vitro Analysis)
...Show More Authors

Urinary stones are one of the most common painful disorders of the urinary system. Four new technologies have transformed the treatment of urinary stones: Electrohydraulic lithotripsy, ultrasonic lithotripsy, extracorporeal shock wave lithotripsy, and laser lithotripsy.The purpose of this study is to determine whether pulsed holmium laser energy is an effective method for fragmenting urinary tract stones in vitro, and to determine whether stone composition affects the efficacy of holmium laser lithotripsy. Human urinary stones of known composition with different sizes, shapes and colors were used for this study. The weight and the size of each stone were measured. The surgical laser system which used in our study is Ho:YAG laser(2100nm)

... Show More
View Publication Preview PDF