Preferred Language
Articles
/
GBedRo4BVTCNdQwCiEB8
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperature from testing rig are used to extract the temperature distribution, local Nusselt number and average Nusselt number. Moreover, a comparison between the numerical result of the same problem published recently and present experimental results has been executed and discussed. It is evinced that; the heat transfer and fluid flow are affected by thickness of porous layer and be maximum at porous layer thickness (0.25L) with larger heater length(20cm) and heat flux (q= 600 Watt/m2) which is approximately (180%) for the average Nu when compared with (Hp=0.75L). Also, the effect of the increasing in heater length (δ) on the averaged heat transfer enhancement is more pronounced for large heater size and 25% of average enhancement is achieved for (δ=20cm) compared to (δ=7cm). However, the greater temperature distribution is found at Hp=2.5cm and 5cm at bottom and first quarter of the cavity (heater surface height Y=0 cm and Y=5 cm) respectively and minimum temperature at top (insulation wall Y=20 cm). Nearly, same shape for heat transfer for different case with clearly difference at small heater (δ=7cm).

Scopus Crossref
View Publication
Publication Date
Sun May 21 2023
Journal Name
Fire
Experimental and Numerical Behavior of Encased Pultruded GFRP Beams under Elevated and Ambient Temperatures
...Show More Authors

In this research, experimental and numerical studies were carried out to investigate the performance of encased glass-fiber-reinforced polymer (GFRP) beams under fire. The test specimens were divided into two peer groups to be tested under the effect of ambient and elevated temperatures. The first group was statically tested to investigate the monotonic behavior of the specimens. The second group was exposed to fire loading first and then statically tested to explore the residual behavior of the burned specimens. Adding shear connectors and web stiffeners to the GFRP beam was the main parameter in this investigation. Moreover, service loads were applied to the tested beams during the fire. Utilizing shear connectors, web stiffeners,

... Show More
Scopus (27)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Wed Feb 05 2003
Journal Name
. Sc. Conf. Of The College 5th Of Eng. Univ. Of Baghdad 2003
COMPUTATIONAL AND EXPERIMENTAL INVESTIGATION OF THE AERODYNAMIC CHARACTERISTICS FOR A FORWARD SWEPT WING AIRCRAFT
...Show More Authors

The aerodynamic characteristics of the forward swept wing aircraft have been studied theoretically and experimentally. Low order panel method with the Dirichlet boundary condition have been used to solve the case of the steady, inviscid and compressible flow. Experimentally, a model was manufactured from wood to carry out the tests. The primary objective of the experimental work was the measurements of the wake dimensions and orientation, velocity defect along the wake and the wake thickness. A blower type low speed (open jet) wind tunnel was used in the experimental work. The mean velocity at the test section was (9.3 m/s) and the Reynolds number based on the mean aerodynamic chord and the mean velocity was (0.46x105). The measurements sho

... Show More
View Publication
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Experimental Performance of a Finned-tube Silica Gel Adsorption Chiller for Air-Conditioning Application
...Show More Authors

This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.

View Publication Preview PDF
Publication Date
Sun Nov 15 2020
Journal Name
Anbar Journal Of Engineering Sciences
Numerical Modelling and Experimental Investigation of Water Distribution in Stratified Soil Under Subsurface Trickle
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Mon Jul 31 2017
Journal Name
Journal Of Engineering
Experimental and Numerical Investigation of Hyper Composite Plate Structure Under Thermal and Mechanical Loadings
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Dec 01 2025
Journal Name
Results In Engineering
Experimental investigation of a solar HDH desalination unit with Pottery tubes in babylon province
...Show More Authors

The Humidification-Dehumidification (HDH) desalination technique offers a viable solution for providing freshwater to populations in water-scarce, remote areas. This study experimentally investigates a novel humidifying method by cross airflow over water-wetted pottery tubes, which function as a humidifier, incorporating a thermoelectric cooler to condense water vapor for freshwater production. To optimize freshwater production and thermal efficiency, meticulous design of these components and appropriate operational parameters are selected. Experiments were performed in three environments with differing temperatures and relative humidity levels, while air velocity varied from 1.02 to 1.89 m/s, and thermoelectric cooler voltage ranged from 6

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Structural Engineering
Experimental and Numerical Evaluation of a Welded Demountable Shear Connector through Horizontal Pushout Tests
...Show More Authors

A novel welded demountable shear connector for sustainable steel-concrete composite structures is proposed. The proposed connector consists of a grout-filled steel tube bolted to a compatible partially threaded stud, which is welded on a steel section. This connector allows for an easy deconstruction at the end of the service life of a building, promoting the reuse of both the concrete slabs and the steel sections. This paper presents the experimental evaluation of the structural behavior of the proposed connector using a horizontal pushout test arrangement. The effects of various parameters, including the tube thickness, the presence of grout infill, and the concrete slab compressive strength, were assessed. A nonlinear finite element mode

... Show More
View Publication
Scopus (24)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Simulation and Experimental Investigation of Performance and Flow Behavior for Steam Ejector Refrigeration System
...Show More Authors

The ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun May 21 2023
Journal Name
Fire
Experimental and Numerical Behavior of Encased Pultruded GFRP Beams under Elevated and Ambient Temperatures
...Show More Authors

In this research, experimental and numerical studies were carried out to investigate the performance of encased glass-fiber-reinforced polymer (GFRP) beams under fire. The test specimens were divided into two peer groups to be tested under the effect of ambient and elevated temperatures. The first group was statically tested to investigate the monotonic behavior of the specimens. The second group was exposed to fire loading first and then statically tested to explore the residual behavior of the burned specimens. Adding shear connectors and web stiffeners to the GFRP beam was the main parameter in this investigation. Moreover, service loads were applied to the tested beams during the fire. Utilizing shear connectors, web stiffeners,

... Show More
View Publication
Scopus (28)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Journal Of Bridge Engineering
Experimental Investigation of Curved-Soffit RC Bridge Girders Strengthened in Flexure Using CFRP Composites
...Show More Authors

View Publication
Crossref (12)
Crossref