Preferred Language
Articles
/
GBcKiI4BVTCNdQwCc0wn
Experimental study on thermo‐hydraulic performance of metal foam twisted tape in a double pipe heat exchanger
...Show More Authors
Abstract<p>A recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (<italic>Nu</italic>) and Nusselt number ratio (<italic>Nu</italic>/<italic>Nu</italic><sub>o</sub>) as the heat exchanger equipped with the proposed MFTT and TTT inserts with various tape‐twist ratios (<italic>y</italic>/<italic>W</italic> = 3.6, 5.2, and 6.8) are considered over various values of Reynolds numbers (16,300 < <italic>Re</italic> < 32,500). The results reveal an improvement in heat transfer rate with both MFTT and TTT and this improvement is proportional inversely to the twisted ratio, but the MFTT showed the highest value of heat transfer compared to TTT and clear tube. Also, the <italic>Nu</italic> of MFTT augments averaged about 175%–230% compared to the TTT depending on the twist ratio and about 275% and 500% over that of the clear tube. At a twist ratio of 3.6, the heat transfer coefficient is recorded at 37% and 45% for MFTT and TTT models, respectively, with an increase in Re. However, friction factor (<italic>f</italic>) increases about 35% for MFTT with decreasing in twist ratio (from 6.8 to 3.6). The effectiveness of the proposed MFTT in the range of <italic>Re</italic> used is found to be about 12%, 15%, and 18% higher than those induced by TTT at twisted tape ratio (<italic>y</italic>/<italic>w</italic> = 3.6, 5.2, and 6.8), respectively.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Sat Feb 28 2015
Journal Name
Al-khwarizmi Engineering Journal
Stabilizing Gap of Pole Electric Arc Furnace Using Smart Hydraulic System
...Show More Authors

Abstract

Electric arc furnace applications in industry are related to position system of its pole, up and down of pole. The pole should be set the certain gap. These setting are needed to calibrate. It is done manually. In this research will proposed smart hydraulic to make this pole works as intelligent using proportional directional control valve. The output of this research will develop and improve the working of the electric arc furnace. This research requires study and design of the system to achieve the purpose and representation using Automation Studio software (AS), in addition to mathematically analyzed and where they were building a laboratory device similar to the design and conduct experiments to stud

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 02 2015
Journal Name
Al-khwarizmi Engineering Journal
Stabilizing Gap of Pole Electric Arc Furnace Using Smart Hydraulic System
...Show More Authors

Preview PDF
Publication Date
Mon Jun 08 2020
Journal Name
Research Journal Of Chemistry And Environment
High Performance Liquid Chromatographic and Areaunder Curve spectrophotometric Methods forEstimation of Cefixime in Pure and MarketedFormulation: A Comparative Study
...Show More Authors

Cefixime is an antibiotic useful for treating a variety ofmicroorganism infections. In the present work, tworapid, specific, inexpensive and nontoxic methods wereproposed for cefixime determination. Area under curvespectrophotometric and HPLC methods were depictedfor the micro quantification of Cefixime in highly pureand local market formulation. The area under curve(first technique) used in calculation of the cefiximepeak using a UV-visible spectrophotometer.The HPLC (2nd technique) was depended on thepurification of Cefixime by a C18 separating column250mm (length of column) × 4.6 mm (diameter)andusing methanol 50% (organic modifier) and deionizedwater 50% as a mobile phase. The isocratic flow withrate of 1 mL/min was applied, the temper

... Show More
Publication Date
Tue Aug 16 2016
Journal Name
International Journal Of Computer Applications
Experimental Study of CLARK-Y Smoothed Inverted Wing with Ground Effect
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Thu Jan 10 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Numerical and Experimental Study of Winglet Effect with Different Cant Angles
...Show More Authors

The present work aims to investigate the aerodynamic characteristics of the winglet cant angle of Boeing 737-800 wing numerically and experimentally. The wing contain two swept angles 38.3o and 29.13o respectively, taper ratio 0.15 and aspect ratio 8.04. The wing involves three types of airfoils sections. Four cant angles for blended winglet have been considered (0o, 34o, 60o, 83.3o). The winglet has been analyzed to find the best cant angle for the wing without and with winglet. These models have been tested theoretically at Reynolds number of 2.06 x106 in order to study the winglet aerodynamic characteristics which consist of coefficient of Drag, coefficient of lift and Lift to drag ratio, pitching moment coefficient and bending moment co

... Show More
Publication Date
Thu Jun 01 2023
Journal Name
Journal Of Engineering
Discharge Coefficient of Contracted Rectangular Sharp-Crested Weirs, an Experimental Study
...Show More Authors

An experimental study is made here to investigate the discharge coefficient for contracted rectangular Sharp crested weirs. Three Models are used, each with different weir width to flume width ratios (0.333, 0.5, and 0.666). The experimental work is conducted in a standard flume with high-precision head and flow measuring devices. Results are used to find a dimensionless equation for the discharge coefficient variation with geometrical, flow, and fluid properties. These are the ratio of the total head to the weir height, the ratio of the contracted weir width to the flume width, the ratio of the total head to the contracted width, and Reynolds and Weber numbers. Results show that the relationship between the discharge co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Simulation and experimental study of Pin-Plate DC discharge plasma technique
...Show More Authors

The present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Numerical Analysis of Laminar Natural Convection in Square Enclosure with and without Partitions and Study Effect of pPartition on the Flow Pattern and Heat Transfer
...Show More Authors

The problem of steady, laminar, natural convective flow in an square enclosure with and without partitions is considered for Rayleigh number (103-106) and Prandtl number (0.7). Vertical walls were maintained isothermal at different temperatures while horizontal walls and the partitions were insulated. The length of partition was taken constant. The number of partitions were placed on horizontal surface in staggered arrangement from (1– 3) and ratio of partition thickness (H/L= 0.033, 0.083, 0.124). The problem is formulated in terms of the vorticity-stream function procedure. A numerical solution based on a program in Fortran 90 with the finite difference method is obtained. Representative results illustrating the effects of the thickn

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 13 2012
Journal Name
Journal Of Kerbala University
Thermo physical behaviour of binary and ternary systems for cyclohexanol with some Ketones at three temperature
...Show More Authors

Publication Date
Tue Aug 23 2022
Journal Name
Frontiers In Energy Research
Evaluation of T-Shaped Fins With a Novel Layout for Improved Melting in a Triple-Tube Heat Storage System
...Show More Authors

The effects of T-shaped fins on the improvement of phase change materials (PCM) melting are numerically investigated in vertical triple-tube storage containment. The PCM is held in the middle pipe of a triple-pipe heat exchanger while the heat transfer fluid flows through the internal and external pipes. The dimension effects of the T-shaped fins on the melting process of the PCM are investigated to determine the optimum case. Results indicate that while using T-shaped fins improves the melting performance of the PCM, the improvement potential is mainly governed by the fin’s body rather than the head. Hence, the proposed T-shaped fin did not noticeably improve melting at the bottom of the PCM domain; additionally, a flat fin is ad

... Show More
View Publication
Scopus (42)
Crossref (28)
Scopus Clarivate Crossref