A randomized clinical trial of the effectiveness of 0.018-inch and 0.022-inch slot orthodontic bracket systems: part 2—quality of treatment
...Show More Authors
Summary<sec><title>Objective

To compare the quality of orthodontic treatment between 0.018-inch and 0.022-inch slot bracket systems.

Subjects and methods

Eligible participants aged 12 years or over were allocated to the 0.018-inch or 0.022-inch slot MBT appliance (3M-Unitek, Monrovia, California, USA) using block randomization in groups of 10. Outcome measures included: 1. ABO cast-radiograph evaluation (CR-EVAL), 2. peer assessment rating (PAR) scores, 3. incisor inclination, and 4. patient perception using the Index of Orthodontic Treatment Need aesthetic component (IOTN AC) and three validated questionnaires before, during and after treatment. Parametric tests [independent samples t-test and two-way analysis of variance (ANOVA)] and non-parametric tests (chi-square with Fisher’s exact tests and Mann–Whitney U-test) assessed differences between groups (P &lt; 0.05).

Results

Of the 187 participants randomized (1:1 ratio), 34 withdrew or were excluded (protocol deviations or poor cooperation). There were 77 patients in the 0.018-inch slot group and 76 patients in the 0.022-inch slot group (overall mean age: 19.1 years). Baseline characteristics were similar between groups (P &gt; 0.05). The mean total ABO CR-EVAL scores were 34.7 and 34.5; mean percentage PAR score reduction 74.1 per cent and 77.1 per cent; mean change for maxillary incisor inclination 2.9 degrees and 1.6 degrees and for mandibular incisor inclination 2.7 degrees and 1.4 degrees for the 0.018-inch and 0.022-inch groups, respectively. Improvement in patient perception of aesthetics after treatment was statistically significant for both groups (P &lt; 0.05). However, there were no statistically significant differences between the two treatment groups for ABO CR-EVAL, percentage PAR score reduction, incisor inclination, and patient perception of treatment (P &gt; 0.05). No adverse events were observed during treatment.

Limitations

It was impossible to blind clinicians or patients to allocation and oral hygiene and periodontal outcomes were not assessed.

Conclusions

There were no statistically or clinically significant differences in the quality of occlusal outcomes, incisor inclination and patient perception of treatment between 0.018-inch and 0.022-inch slot bracket systems.

Registration

The trial was registered with ClinicalTrials.gov on 5 March 2014, registration number: NCT02080338.

Protocol

The protocol was published at DOI: 10.1186/1745-6215-15-389.

Crossref
View Publication
Publication Date
Wed Jul 11 2018
Journal Name
European Journal Of Orthodontics
A randomized clinical trial of the effectiveness of 0.018-inch and 0.022-inch slot orthodontic bracket systems: part 1—duration of treatment
...Show More Authors

View Publication
Crossref (20)
Crossref
Publication Date
Wed Jul 11 2018
Journal Name
European Journal Of Orthodontics
A randomized clinical trial of the effectiveness of 0.018-inch and 0.022-inch slot orthodontic bracket systems: part 3—biological side-effects of treatment
...Show More Authors

View Publication
Crossref (21)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
The Angle Orthodontist
Does anchorage loss differ with 0.018-inch and 0.022-inch slot bracket systems?
...Show More Authors
ABSTRACT<sec id="st1"> <title>Objectives:

To compare maxillary first molar anchorage loss between 0.018-inch and 0.022-inch slot fixed appliance systems.

Materials and Methods:

Patients requiring bilateral maxillary premolar extractions (n = 74) within a randomized clinical trial comparing the effectiveness of 0.018-inch and 0.022-inch slot MBT bracket systems (3M-Unitek, Monrovia, Calif) were included. Three-dimensional pre- and posttreatment digital models were landmarked and me

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Mon Feb 03 2020
Journal Name
European Journal Of Orthodontics
A clinical comparison of the effectiveness of two types of orthodontic aligning archwire materials: a multicentre randomized clinical trial
...Show More Authors
Summary<sec><title>Objectives

To compare the heat-activated nickel titanium (HANT) with superelastic nickel-titanium (SENT) archwires in terms of their effectiveness of aligning teeth, possibility of inducing root resorption, and perception of pain.

Subjects and methods

Orthodontic patients aged 12 years or over with mandibular anterior crowding of 3–6 mm, who required treatment without extractions were randomly allocated (a simple non-stratified randomization) to the HANT and SENT archwires groups with a 1:1 allocation ratio. The archwire sequence in both groups was 0.014-inch and 0.016-inch, respectively. Each archwire was

... Show More
View Publication
Crossref (17)
Crossref
Publication Date
Mon Feb 12 2024
Journal Name
Bmc Oral Health
A scanning electron microscopy investigation of the precision of three orthodontic bracket slot systems
...Show More Authors
Abstract<sec> <title>Objective

One of the most imprortant factors in achieving ideal teeth positions is the precision of the slot dimensions of orthodontic brackets into the archwires are inserted.This study aimed to assess the accuracy of the dimensions of orthodontic bracket slots and molar buccal tube apertures and to compare them with the specifications provided by the manufacturers.

Method

A total of sixty brackets and ten molar buccal tubes with varying slot heights were examined using a scanning electron microscope from the mesial side. Th

... Show More
View Publication
Scopus (6)
Crossref (8)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
International Orthodontics
Effectiveness of tubular coaxial nickel-titanium and copper nickel-titanium orthodontic aligning archwires: A randomized clinical trial
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Orthodontic Science
Evaluating orthodontic bracket slot dimensions and morphology: A narrative review
...Show More Authors

The current article aims to review the previous studies that measure the orthodontic bracket slot dimensions and geometry. Searches in different databases, including PubMed Central, Science Direct, Wiley Online Library, the Cochrane Library, Textbooks, Google Scholar, and Research Gate, in addition to a manual search, were performed about the methods of assessing orthodontic bracket slot dimension up to March 2023. The irrelevant and duplicate studies were eliminated, leaving 35 studies for this narrative review. The findings indicate that the slots are oversized with diverging walls in most studies. Manufacturers must respect the standards during manufacturing brackets and adhere to the actual dimensions and tolerance values.

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Thu Sep 01 2022
Journal Name
European Journal Of Orthodontics
Effect of calcium fluoride nanoparticles in prevention of demineralization during orthodontic fixed appliance treatment: a randomized clinical trial
...Show More Authors
Summary<sec><title>Background

White spot lesions (WSLs) are the most common complications of fixed appliance orthodontic treatment.

Objectives

To evaluate the effectiveness of calcium fluoride nanoparticles-containing orthodontic primer (nCaF2-primer) in preventing the incidence of WSLs during orthodontic treatment.

Trial design

Single-centre, double-blinded, split-mouth, randomized clinical trial.

Methods

The sample involved 31 orthodontic patients (≥12 years). Participants were recruited using a simple

... Show More
View Publication
Scopus (18)
Crossref (17)
Scopus Crossref
Publication Date
Sun Feb 01 2026
Journal Name
Journal Of Taibah University Medical Sciences
Acupressure versus paracetamol for short-term orthodontic pain: A randomized clinical trial
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Oct 24 2024
Journal Name
Scientific Reports
Effectiveness of high-frequency vibration, cotton rolls and elastomeric wafers in alleviating debonding pain of orthodontic metal brackets: a randomized clinical trial
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref