Preferred Language
Articles
/
FxdxP48BVTCNdQwCk2bn
Flexible ureterorenoscopy versus extracorporeal shock wave lithotripsy for treatment of lower pole renal stones
...Show More Authors

Scopus
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Electrical stimulation for the treatment of Knee joint osteoarthritis
...Show More Authors

Abstract 20 patients with osteoarthritis of the knee joint were treated by electrical stimulation in the form of 6 sessions every other day each sessions of diphase fixe (DF) for 4 minutes followed by rest for 4 minutes then treated with a monophase fixe (MF) for 2 minutes. By clinical & statistical analysis ( P value < 0.05) we conclude that the electrical stimulation is effective as one method in the treatment of osteoarthritis.

View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Heterogeneous Photocatalytic Degradation for Treatment of Oil from Wastewater
...Show More Authors

In the present study, advanced oxidation process / heterogeneous photocatalytic process (UV/TiO2/Fenton) system was investigated to the treatment of oily wastewater. The present study was conducted to evaluate the effect of hydrogen peroxide concentration H2O2, initial amount of the iron catalyst Fe+2, pH, temperature, amount of TiO2 and the concentration of oil in the wastewater.  The removal efficiency for the system UV/TiO2/Fenton at optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=5, temperature =30oC, TiO2=75mg/L) for 1000mg/L load was found to be 77%.

Aluminum foil cover around the re

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 13 2022
Journal Name
Iraqi Journal Of Science
In Situ Measuring of Relative Dielectric Permittivity to Calculate Electromagnetic Wave Velocity
...Show More Authors

The relative dielectric permittivity (dielectric constant) values for various materials are measured on site. The calculated values that are derived from measuring the ratio of the electrical capacitance of a cell when the sample of the material is placed. Parallel plate technique that consists of two parallel circular metallic plates is used. The instrument made up of aluminum which acts as electrodes and stuffed inside the PVC cylinder. Then the thin sheet of material (models) sandwiched between the two plates. Calculation of dielectric constant (εr) through this new technique gives a new velocity value of electromagnetic wave that propagates underground. These measured velocity values will utilize in Ground Penetration Radar (GPR) da

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 27 2018
Journal Name
International Journal Of Hydrogen Energy
Compressional wave velocity of hydrate-bearing bentheimer sediments with varying pore fillings
...Show More Authors

A potential alternative energy resource to meet energy demands is the vast amount of gas stored in hydrate reserves. However, major challenges in terms of exploration and production surround profitable and effective exploitation of these reserves. The measurement of acoustic velocity is a useful method for exploration of gas hydrate reserves and can be an efficient method to characterize the hydrate-bearing sediments. In this study, the compressional wave velocity (P-wave velocity) of consolidated sediments (Bentheimer) with and without tetrahydrofuran hydrate-bearing pore fillings were measured using the pulse transmission method. The study has found that the P-wave velocity of consolidated sediments increase with increasing hydrate format

... Show More
Scopus (42)
Crossref (42)
Scopus Clarivate Crossref
Publication Date
Thu Apr 27 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Measurement of Electromagnetic wave Emitted from Home Appliance by Milligauss meter
...Show More Authors

   The appliance of milligauss meter was designed by Qusay Ismail to measure the induce of electromagnetic field for home appliance which are put at a distance from milligauss meter (15-30-60)cm .The results showed some appliance has recorded higher than normal acceptable level of electromagnetic radiation emissions and produced radiation of (350650)milligauss as for the rest of appliances has recorded values which are ranged between (1200)milligauss ,laptop was recorde radiation generally lower than from desktop and computer moniter (CRT).The radiation ,intensity decrease with increasing distance.

View Publication Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Slow sand filtration as a tertiary treatment for the secondary effluent from sewage treatment plant
...Show More Authors

A field-pilot scale slow sand filter (SSF) was constructed at Al-Rustamiya Sewage Treatment Plant (STP) in Baghdad city to investigate the removal efficiency in terms of Biochemical Oxygen Demand (BOD5), Chemical oxygen demand (COD), Total Suspended Solids (TSS) and Chloride concentrations for achieving better secondary effluent quality from this treatment plant. The SSF was designed at a 0.2 m/h filtration rate with filter area 1 m2 and total filter depth of 2.3 m. A filter sand media 0.35 mm in size and 1 m depth was supported by 0.2 m layer of gravel of size 5 mm. The secondary effluent from Al-Rustamiya STP was used as the influent to the slow sand filter. The results showed that the removal of BOD5, COD, TSS, and Chloride were

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of International Dental And Medical Research
Evaluation of selection criteria for patients indicated for fixed orthodontic appliance treatment
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sat Sep 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Air Gap Width (S) and the Ratio (P1/D2) on .Minimum Projector Focal Length (Fp)min for the Double Pole-Piece Lens- at Costant Excitation (NI)
...Show More Authors

The  spherical  double pole-piece  electron  lens i§ depend  on some

fact0rs : the-  minimum va}ue-of projector  fo·cal  length (Fp)i:J,Iill  â€¢  the

maximum value of  magnetic flux density (Bm) , the total  hal[ width

,(W)  o'f asyriunetrical   clln'e  of  magnetic field  distribution  [because there are differe_nt values of bore diameter  (D1) • i.                                           &

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 07 2022
Journal Name
Journal Of Educational And Psychological Researches
Moral identity and its relationship to social affiliation among university students Exposed to shock pressure
...Show More Authors

The current research aimed to identify the level of moral identity and social affiliation among students exposed to shock pressures, as well as to reveal the relationship between these variables. To achieve these objectives, the researcher adopted the diagnostic tool for the measure of post-traumatic stress disorder (PDS-5) scale (Foa, 2013) translated to Arabic language by (Imran, 2017). The researcher also adopted the moral identity scale built by (Al-Bayati, 2015) and the measure of social affiliation built by (Al-Jashami, 2013), which were applied to a random sample of (200) male and female students chose from al Anbar University. They were exposed to shock pressures. The results of the research showed that the sample has an average

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 31 2021
Journal Name
Iraqi Journal Of Science
Characterization of Flexible Multi-Walled Carbon Nanotubes Network Sensor to Freon Gas Detection
...Show More Authors

     MWCNTs-OH was used to prepare a flexible gas sensor by deposition as a network on a filter cake using the method of filtration from suspension (FFS). The morphological and structural properties of the MWCNTs network were characterized before and after exposure to Freon gas using FTIR spectra and X-ray diffractometer, which confirmed that the characteristics of the sensor did not change after exposure to the gas. The sensor was exposed to a pure Freon134a gas as well as to a mixture of Freon gas and air with different ratios at room temperature. The experiments showed that the sensor works at room temperature and the sensitivity values increased with increasing operating temperature, to be 58% unt

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (5)
Scopus Crossref