Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the determination of propranolol at concentration (0.5,10 and 25) mmol/L, respectively to cell A and cell B. Results were compared with classical methods UV-Spectrophotometric at λ max = 289 nm and turbidimetric method by using standard addition method via t-test at 95% level confidence. The comparison of data explains that long-distance chasing photometer (NAG-ADF-300-2) is the choice with extended stellar detection and broad application.

Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Newly Developed System For The Analysis Of Micro Quantites Of Molybdenum (VI) Using Flow Injection Analysis
...Show More Authors

New microphotometer was constructed in our Laboratory Which deals with the determination of Molybdenum (VI) through its Catalysis effect on Hydrogen peroxide and potasum iodide Reaction in acid medium H2SO4 0.01 mM. Linearity of 97.3% for the range 5- 100 ppm. The repeatability of result was better than 0.8 % 0.5 ppm was obtanined as L.U. (The method applied for the determination of Molybdenum (VI) in medicinal Sample (centrum). The determination was compared well with the developed method the conventional method.

View Publication Preview PDF
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Normal and Reverse Flow Injection Analysis Methods for Estimation of Mesalazine in Pharmaceutical Dosage Forms
...Show More Authors

Determining the actual amounts of active ingredients in various pharmaceutical commercial forms is still receiving a lot of attention. Two flow injection analysis (FIA) methods were suggested for determination of mesalazine (MES) in pharmaceutical forms. Normal and reverse FIA systems (nFIA and rFIA) combined with UV-Vis spectrophotometric technique were used for the analysis. The methods involved using two mods of FIA systems for measuring a colored product result from coupling of MES with 2,2'-dihydroxybiphenyl after oxidized with sodium periodate in alkaline medium. The absorbance of the red colored dye was measured at maximum wavelength of 500 nm. The calibration graphs for MES were linear in the ranges 2.5-200 and 0.5-60 µg/mL with

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry
...Show More Authors

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
New sensitive turbidimetric method for determination of losartan potassium in pharmaceutical formulations using flow injection combined with homemade turbidimeter
...Show More Authors

Scopus
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Procaine HCl in Pharmaceutical Preparations Via Using Diazotization and Coupling Reaction
...Show More Authors

Simple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. A

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Study the Impact of the Distance Factor on the Optimal Workable Frequencies for the Long Distance Radio Communications
...Show More Authors

In this research, the influence of the distance factor on the optimal working
frequency (FOT) parameter has been studied theoretically for the ionosphere layer
over the Middle East Zone. The datasets of the (FOT) parameter have been
generated using the (VOACAP) model which considers as one of the recommended
modern international communication models that used to calculate the ionosphere
parameters. The calculations have been made for the connection links between the
capital Baghdad and many other locations that distributed on different distances and
directions over the Middle East region. The years (2011-2013) of the solar cycle 24
have been adopted to study the influence of the distance factor on the FOT
param

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Doxycycline Hyclate by Batch and Reverse Flow Injection Analysis Based on the Oxidative Coupling Reaction with 3-Methyl-2-benzothiazolinone Hydrazone hydrochloride (MBTH)
...Show More Authors

New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Virology
Chloroviruses Lure Hosts through Long-Distance Chemical Signaling
...Show More Authors

Viruses have not previously been reported to act as chemotactic/chemoattractive agents. Rather, viruses as extracellular entities are generally viewed as non-metabolically active spore-like agents that await further infection events upon collision with appropriate host cells. That a virus might actively contribute to its fate via chemotaxis and change the behavior of an organism independent of infection is unprecedented.

View Publication
Scopus (13)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Al-rafidain University College For Sciences
“Simple Regression Analysis by using Linear Programming Technique and illustration of Absolute Residuals method with another Estimation Techniques”
...Show More Authors

This research deals with unusual approach for analyzing the Simple Linear Regression via Linear Programming by Two - phase method, which is known in Operations Research: “O.R.”. The estimation here is found by solving optimization problem when adding artificial variables: Ri. Another method to analyze the Simple Linear Regression is introduced in this research, where the conditional Median of (y) was taken under consideration by minimizing the Sum of Absolute Residuals instead of finding the conditional Mean of (y) which depends on minimizing the Sum of Squared Residuals, that is called: “Median Regression”. Also, an Iterative Reweighted Least Squared based on the Absolute Residuals as weights is performed here as another method to