In the theoretical part, removal of direct yellow 8 (DY8) from water solution was accomplished using Bentonite Clay as an adsorbent. Under batch adsorption, the adsorption was observed as a function of contact time, adsorbent dosage, pH, and temperature. The equilibrium data were fitted with the Langmuir and Freundlich adsorption models, and the linear regression coefficient R2 was used to determine the best fitting isotherm model. thermodynamic parameters of the ongoing adsorption mechanism, such as Gibb's free energy, enthalpy, and entropy, have also been measured. The batch method was also used for the kinetic calculations, and the day's adsorption assumes first-order rate kinetics. The kinetic studies also show that the intraparticle diffusion process was active. Density Functional Theory (DFT) was used to study the dye structure with Gaussian 09 and predict the active site in a molecule using total electron density (TED) and electrostatic surface potential (ESP).
Foreign direct investment is considered one of important bases to blind economy for many. Countries as if the main stage for developing national economy ,so for this ,many of countries give great prominence to the role of drivel foreign investment due to its importance as one of economic growth pillars in the developing countries. They offer a support for modern technology, organizational and managerial skills.
Dneto the importance of direct foreign investment on the economic growth, today, we discover that Iraq in need to rebnlid the in frastructuve and renew what has been destroyed during was in many production and export institutions . as wel
... Show MoreThis work deals with preparation of zeolite 5A from Dewekhala kaolin clay in Al-Anbar region for drying and desulphurization of liquefied petroleum gas. The preparation of zeolite 5A includes treating kaolin clay with dilute hydrochloric acid 1N, treating metakaolin with NaOH solution to prepare 4A zeolite, ion exchange, and formation. For preparation of zeolite 4A, metakaolin treated at different temperatures (40, 60, 80, 90, and 100 °C) with different concentrations of sodium hydroxide solution (1, 2, 3, and 4 N) for 2 hours. The zeolite samples give the best relative crystallinity of zeolite prepared at 80 °C with NaOH concentration 3N (199%), and at 90 and 100°C with NaOH concentration solution 2N (184% and 189%, respectively). Ze
... Show More
The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c
... Show MoreTo investigate the role of IL-6 and IL-8 in the immune-regulatory mechanisms involved in the recurrent spontaneous abortion of the first trimester of pregnancy. Serum level of IL-6 and IL-8 were determined in 25 women of age (20-35) years who had a spontaneous abortion of unknown aetiology during the first trimester of pregnancy .They were compared with the corresponding levels of 20 pregnant and non-pregnant women as control groups .cytokine levels were measured by (ELISA) technique .The women with spontaneous abortion had highly significant (P < 0.01) increased serum level of IL-8 and highly significant (P < 0.01 ) decreased level of IL-6 compared to those with normal pregnant and non-pregnant women. The results of this study ma
... Show MoreThe current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show More