Preferred Language
Articles
/
FYa_YIYBIXToZYAL5ols
Antibiotics adsorption from contaminated water by composites of ZSM-5 zeolite nanocrystals coated carbon
...Show More Authors

The presence of antibiotic residues such as ciprofloxacin (CIPR) in an aqueous environment is dangerous when their concentrations exceed the allowable. Therefore, eliminating these residues from the wastewater becomes an essential issue to prevent their harm. In this work, the potential of efficient adsorption of ciprofloxacin antibiotics was studied using eco-friendly ZSM-5 nanocrystals‑carbon composite (NZC). An inexpensive effective natural binder made of the sucrose-citric acid mixture was used for preparing NZC. The characterization methods revealed the successful preparation of NZC with a favorable surface area of 103.739 m2/g, and unique morphology and functional groups. Investigating the ability of NZC for adsorbing CIPR antibiotics conducted at different conditions showed that 0.3 g of NZC achieved outstanding adsorption for 150 ppm CIPR antibiotic from 100 mL solutions at mixing speed of 200 rpm, solution pH of 4–6, and solution temperature of 25–30 ◦C. Estimating the values of ΔH◦, ΔS◦, and ΔG◦ confirmed that the adsorption process of CIPR antibiotics by NZC was feasible, exothermic and spontaneous. The Freundlich and pseudo-second-order models well fitted the adsorption process's experimental data. The results of both the kinetic and isotherm studies showed that the adsorption process of CIPR antibiotics by NZC is simultaneously composed of physical and chemical adsorption on the heterogeneous adsorption sites in multilayers. Also, the intra-particle diffusion was not the controlling step and the external surface adsorption influenced the adsorption of CIPR. From the abovementioned results, NZC is recommended as a highly efficient adsorbent for the removal of CIPR-loaded effluents.

Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Assessment of surface water quality using statistical analysis methods: Orontes River (Case study)
...Show More Authors

The study investigates the water quality of the Orontes River, which is considered one of the important water recourses in Syria, as it is used for drinking, irrigation, swimming and industrial needs. A database of 660 measurements for 13 parameters concentrations used, were taken from 11 monitoring points distributed along the Orontes River for a period of five years from 2015-2019, and to study the correlation between parameters and their impact on water quality, statistical analysis was applied using (SPSS) program. Cluster analysis was applied in order to classify the pollution areas along the river, and two groups were given: (low pollution - high pollution), where the areas were classified according to the sources of pollution to w

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Corrosion Study of the Injection Equipments in Water in Al-Ahdeb Wells ‐Iraq
...Show More Authors

Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the
pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves removing the dissolved O2 from w

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Geological Journal
ASSESSMENT OF GROUNDWATER QUALITY USING WATER QUALITY INDEXIN, AL-HAWIJA AREA, NORTHERN IRAQ
...Show More Authors

The quality of groundwater in the Al-Hawija area was assessed using a water quality index. Data of nine physico-chemical parameters of 28 groundwater wells were used to calculate the water quality index (WQI). A heterogeneous water quality was reported, where in close proximity to the Lesser Zab River (LZR), it has low WQI values and permissible for human consumptions due to the dilution processes by fresh water; whereas, it becomes deteriorated in areas located far away the river. The values of WQI ranges from 22 to 336, indicating a good to very poor groundwater quality.

View Publication
Crossref (3)
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Iraqi Geological Journal
THE EFFECT OF SOME MATERIALS ON FUNNEL VISCOSITY READING IN WATER BASE MUD
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Impact of Design Parameters in Thermal Solar Water Storage Tank Systems: (A Review)
...Show More Authors

This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectan

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Absorption of NO2 into Water and Nitric Acid Solutions in a Fixed Column
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Antibacterial Activity of Electrospun Silver Nitrate /Nylon 6 Polymeric Nanofiber Water Filtration Mats
...Show More Authors

Bacterial water pollution is a genuine general wellbeing concern since it causes various maladies. Antimicrobial nanofibers can be integrated by incorporating nanobiocides, for example, silver nanoparticles into nanofibers. Nylon 6 was dissolved in formic acid at a concentration of (25 wt. %) and tough antibacterial (AgNO3/Nylon) nanofibers were produced utilizing electrospinning system. Polymer solution was tested before accomplishing electrospinning process to acquire its surface tension, electric conductivity and viscosity, where every one of those parameters increased relatively with increasing concentration of (AgNO3) additions. SEM and EDX spectra were utilized to focus on the morphology, surface elemental mem

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Nutrient and Water Use Efficiency of Broccoli Cultivated Hydroponically on Alternative Solution ABEER
...Show More Authors
Abstract<p>A Field experiment was conducted in Horticulture and Landscape Department, College of Agricultural Engineering Sciences, University of Baghdad, Al-Jadriah during fall 2019-2020 to study nutrient and water use efficiency of broccoli cultivated hydroponically on alternative solution ABEER. Nested design with three replications adopted in the experiment, each of them included in main plot the first factor, which is gas enrichment (O<sub>2</sub> and O<sub>3</sub>), Then levels of second factor were randomly distributed within each replicate, which included spraying with plants extracts which was Moringa leaves extract and Coconut water at two concentrations 2, 4 %and 5</p> ... Show More
View Publication
Scopus Crossref