In this research, the seasonal Optimal Reliable Frequency (ORF) variations between different transmitter/receiver stations have been determined. Mosul, Baghdad, and Basra have been chosen as tested transmitting stations that located in the northern, center, and southern of Iraqi zone. In this research, the minimum and maximum years (2009 and 2014) of solar cycle 24 have been chosen to examine the effect of solar activity on the determined seasonal ORF parameter. Mathematical model has been proposed which leads to generate the Optimal Reliable Frequency that can maintain the seasonal connection links for different path lengths and bearings. The suggested ORF parameter represented by a different orders polynomial equation. The polynomial equation has been determined depending on different selected parameters (path length, bearing, time (day), months and BUF values). The suggested seasonal ORF parameter was examined for the three stations of the adopted years. The value of the seasonal ORF ionospheric parameter increased with the increase of path length and varies with the bearing between the transmitting and receiving stations also, the seasonal ORF values were higher at maximum solar cycle (2014) than the minimum solar cycle (2009).
Abstract
The issue of inequality in distribution of income and / or consumption expenditure is related to economic welfare because there is an inverse relationship between the economic welfare on the one hand, and the degree of inequality, on the other hand. Despite the fact that inequality is considered as normal phenomenon in every society, but if it exceeded certain limits it will lead to undesirable economic, social and political consequences. Therefore, the availability of indicators about inequality is a necessary tool for planning and evaluation of economic development programs. So, current study is aiming at measuring and analyzing the degree of inequality in distribution of consumpti
... Show MoreIntroduction. Intraoperative rupture (IOR) of an aneurysm is a frightful complication that causes significant morbidity and mortality worldwide. IOR can be attributed to various parameters, including hypertension, increased intracranial pressure (ICP), fragility of the vessels, and inadequate anaesthesia. IOR due to insufficient anaesthesia is scarcely reported in the literature. Here, we describe a re-ruptured anterior communicating artery (ACoA) after incomplete clipping of the neck during craniotomy closure due to unintended early wake-up from anaesthesia with a discussion about the management. Case description. A 38-year-old male suddenly developed a severe headache, a brief loss of consciousness, and vomiting. Computed tomogr
... Show MoreBackground: During the pandemic, Corona virus forced many people, especially students, to spend more time than before on the computer and smartphone to study and communicate. The poor posture of the body may have worse effect on its body parts , most of which is the cervical spine (forward head posture). Objective: To assess the incidence of neck pain and the associated factors among undergraduate medical students related to position during E learning Subjects and Methods: Cross-sectional study was conducted among medical students in three Iraqi universities during 2021. The sample size was 152. Online questionnaire by Google forms sampling method were used to collect the data which was analysed using SPSS 25. Results: The perce
... Show More
Background: During the pandemic, Corona virus forced many people, especially students, to spend more time than before on the computer and smartphone to study and communicate. The poor posture of the body may have worse effect on its body parts , most of which is the cervical spine (forward head posture). Objective: To assess the incidence of neck pain and the associated factors among undergraduate medical students related to position during E learning Subjects and Methods: Cross-sectional study was conducted among medical students in three Iraqi universities during 2021. The sample size w |
The design, construction and investigation of experimental study of two compound parabolic concentrators (CPCs) with tubular absorber have been presented. The performance of CPCs have been evaluated by using outdoor experimental measurements including the instantaneous thermal efficiency. The two CPCs are tested instantly by holding them on a common structure. Many tests are conducted in the present work by truncating one of them in three different levels. For each truncation the acceptance half angle (θc) was changed. Geometrically, the acceptance half angle for standard CPC is (26o). For the truncation levels for the other CPC 1, 2 and 3 the acceptance half angle were 20o, 26o and 5
... Show MoreNumerical study of separation control on symmetrical airfoil, four digits (NACA
0012) by using rotating cylinder with double steps on its upper surface based on the computation of Reynolds-average Navier- Stokes equations was carried out to find the optimum configuration of unconventional airfoil for best aerodynamics performance. A model based on collocated Finite Volume Method was developed to solve the governing equations on a body-fitted coordinate system. A revised (k-w) model was proposed as a known turbulence model. This model was adapted to simulate the control effects of rotating cylinder. Numerical solutions were performed for flow around unconventional airfoil with cylinder to main stream velocities ratio in the range
... Show MoreThe current research aims to identify the effectiveness of a computerized program in developing mathematical skills among the first cycle students in basic education schools in the Sultanate of Oman. The two researchers used the quasi-experimental approach on an intentional sample consisting of (40) male and female students at Al Kawakeb School for Basic Education (1-4). Two of the basic fourth-grade classes and then randomly distributing them into two groups, one is experimental (20) male and female students who followed the computerized interactive program, and the other is (20) male and female students followed the traditional way. On the other hand, its reliability has reached (0.81), and the results of the research have concluded th
... Show MoreAn experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.