This paper is an attempt to investigate the syntactic and semantic features of the English phrasal verbs. In this paper, phrasal verbs were classified into subgroups according to their syntactic and semantic characteristics. After giving a survey of literature written on the meaning and definition of phrasal verbs, two sections have been devoted to tackle the most important issues in this category of English verbs. Section one sheds light on the basic definitions of the term ‘phrasal verb’ which are, according to the researcher’s point of view, sufficient to cover the area of the study. In addition, it studies the number and the importance of phrasal verbs in English. Section two deals with the syntactic and semantic features of English phrasal verbs. It shows whether these phrasal verbs are transitive \ intransitive and separable\ inseparable, as well as it focuses on the differences between phrasal verbs and prepositional verbs. Finally, the literal and idiomatic usage of English phrasal verbs has been tackled. In the light of the findings of the study a number of conclusions are drawn
This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs
... Show MoreKurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.
Background: Bacteriocin is a peptidic toxin has many advantages to bacteria in their ecological niche and has strong antibacterial activity. Objective: The aim of this study was to evaluation of bacteriocin using Streptococcus sanguinis isolated from human dental caries.
Subjects and Methods: Thirty five streptococcus isolates were diagnosed and tested for their production of bacteriocin, and then the optimal conditions for production of bacteriocin were determined. After that, the purification of bacteriocin was made partially by ammonium sulfate at 95% saturation levels, followed by and gel filtration chromatography
... Show MoreThe local authority represented by the Provincial Council and the administrative units thereof has legislative and supervisory functions which are in the administration and supervision of the local public utilities as provided for by the laws in force. The subject of the interactive relationship between the federal authority and the provincial councils not organized in one of the main problems that accompanied the emergence and application of decentralized system Iraq after 2003, which began since the writing of the Constitution in force for the year 2005 and the law of the provinces No. 21 of 2008 This law has been subjected to political recordings that eventually led to the appearance of this consensus image. The weakness of the legisl
... Show MoreThe standard formulation of Wave Intensity Analysis (WIA) assumes that the flow velocity (U) in the conduit is <;<; the velocity of propagation of waves (c) in the system, and Mach number, M=U/c, is negligible. However, in the large conduit arteries, U is relatively high due to ventricular contraction and c is relatively low due to the large compliance; thus M is > 0, and may not be ignored. Therefore, the aim of this study is to identify experimentally the relationship between M and the reflection coefficient in vitro. Combinations of flexible tubes, of 2 m in length with isotropic and uniform circular cross sectional area along their longitudinal axes, were used to present mother and daughter tubes to produce a range of reflection coeffic
... Show MoreThe internet of medical things (IoMT), which is expected the lead to the biggest technology in worldwide distribution. Using 5th generation (5G) transmission, market possibilities and hazards related to IoMT are improved and detected. This framework describes a strategy for proactively addressing worries and offering a forum to promote development, alter attitudes and maintain people's confidence in the broader healthcare system without compromising security. It is combined with a data offloading system to speed up the transmission of medical data and improved the quality of service (QoS). As a result of this development, we suggested the enriched energy efficient fuzzy (EEEF) data offloading technique to enhance the delivery of dat
... Show More