In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical parameters included: pH value, Alkalinity (ALK), Orthophosphate (PO4-3), Nitrate (NO3-), Sulphate (SO4-2), Chloride (Cl-), Total Hardness (TH), Calcium (Ca), Magnesium (Mg), and Total Dissolved Solids (TDS). The average annual overall WQI was found to be 107.59 through the study period. The high WQI obtained is a result of the high concentrations of Orthophosphate and Magnesium which can be attributed to the various human activities taking place along the river banks. From this analysis the quality of the Euphrates River is classified as "very poor quality" ranging poor water at the river upstream near station (E1) and unsuitable for drinking at the river downstream near station (E7) with an annual minimum WQI of 89.34 in 2008 and maximum 112.44 in 2009. The present study demonstrated the application of WQI in estimating and understanding the water quality of Euphrates River. WQI appears to be promising in water quality management and a valuable tool in categorizing pollution sources in surface waters.
Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa
The present study included the physico-chemical parameters of Lesser-Zab river and its effects on Tigris river. Monthly water samples were taken from the two rivers during January to October 1999.There were no signifcant difference in water temperatures. Both rivers were fresh to oligohalin, alkaline and very hard. Close values were determined in total suspended solids in both rivers with little increasing during rainfall period and high discharge. Water was well areated and over saturation was recorded in several occasions. Dissolved oxygen values of Tigris river were influenced by Lesser-Zab. Cations were more dominant than anions in both rivers. In Lesser-Zab, the anions were increased during spring season and declined in summer which t
... Show MoreThe vacancy of natural resources is undoubtedly limited by time. The sustainable development principle recommends modern technology for its protection and renewal. This project conducted analyses on two underground water sources in the north of Algeria (Mechroha Province). Besides, the use of the hardness factor and the adoption of the titration method, which is the determining the concentration of an unknown solution using a known solution concentration, have permitted the characterization of the examples taken and to verify their conformity to the standard required, the results found showed HT=6.66 French degrees (oF) ) for Ain Guilloume water spring in comparison to Ain Messai water spring H
A field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of th
Well-dispersed Cu2FeSnSe4 (CFTSe) nanoparticles were first synthesized using the hot-injection method. The structure and phase purity of as-synthesized CFTSe nanoparticles were examined by X-ray diffraction (XRD) and Raman spectroscopy. Their morphological properties were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The average particle sizes of the nanoparticles were about 7-10 nm. The band gap of the as-synthesized CFTS nanoparticles was determined to be about 1.15 eV by ultraviolet-visible (UV-Vis) spectrophotometry. Photoelectrochemical characteristics of CFTSe nanoparticles were also studied, which indicated their potential application in solar energy water splitting.
Study of Direct Marketing techniques and determining the scope of the suitability of each of them in the application in the Iraqi market - An analytical and explorative study for sample of views for wholesaler in Baghdad. The essential idea of the research is to go into the most important concepts which have been mentioned in the direct marketing and determining its current and most important techniques and knowing the scope of applying these techniques in Baghdad main markets (Karrada, Jamilah, shorja, Baya area, zeyouna and new Baghdad) and which of those techniques most applicable in these markets. The research took a sample of (100) wholesalers who practice the activities of selling nutritional items, auto and outs spare part
... Show MoreWhile traditional energy sources such as oil, coal, and natural gas drive economic growth, they also seriously affect people’s health and the environment. Renewable energies (RE) are presently seen as an efficient choice for attaining long-term sustainability in development. They provide an adequate response to climate change and supply sufficient electricity. The current situation in Iraq results from a decades-long scarcity of reliable electricity, which has impacted various industries, including agriculture. There are diverse prospects for using renewable energy sources to address the present power crisis. The economic and environmental impacts of renewable energy systems were investigated in this study by using the solar pumpi
... Show MoreIn the current study, a novel approach for separating ethanol-water mixture by microbubble distillation technology was investigated. Traditional distillation processes require large amounts of energy to raise the liquid to its boiling point to effect removal of volatile components. The concept of microbubble distillation by comparison is to heat the gas phase rather than the liquid phase to achieve separation. The removal of ethanol from the thermally sensitive fermentation broths was taken as a case of study. Consequently the results were then compared with those which could be obtained under equilibrium conditions expected in an “ideal” distillation unit. Microbubble distillation has achieved vapour compositions higher than th
... Show MoreThe significant shortage of usable water resources necessitated the creation of safe and non-polluting ways to sterilize water and rehabilitate it for use. The aim of the present study was to examine the ability of using a gliding arc discharge to inactivate bacteria in water. Three types of Bacteria satisfactory were used to pollute water which are Escherichia coli (Gram-negative), Staphylococcus aurous (Gram-positive) and salmonella (Gram-negative). A DC power supply 12V at 100 Hz frequency was employed to produce plasma. pH of water is measured gradually during the plasma treatment process. Contaminated water treated by gliding arc discharge at steadying the gas flow rate (1.5 l/mi