The risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate and water cuts. External corrosion hazard rating 4 is considered high because there is no coating, no cathodic protection is applied.
An oil spillage has been a great threat to human life in parts of Koya district, especially through the contamination of domestic water. An attempt was made to find and map the extent of pollution in the area. According to a field survey, more than 17 springs and 34 hand-dug and artesian wells have been contaminated with crude oil. The contamination was recorded recently after loading began of tens of oil tankers in the Taq-Taq oil field, and as a result hundred barrels of oil have spilled into the creeks and soil daily. Hence, 2D resistivity imaging was adopted via four laid-out traverses running normal to the strike of the outcrops. A Wenner-Schlumberger array configuration was used to achieve both vertical and lateral resistivity dist
... Show MoreTrace elements (Co, Cr, Mn, Mo, Ni, Rb, Th, U, and V) in surface soil of Al-Aslah (NH1), Nasiriyah refinery (NH2), Gharraf (NH3), and Tall Al-Laham (NH4) at Thi-Qar governorate, southeast Iraq, were studied. The study aims to detect their distribution and pollution levels to reduce the subtracted from industrial sources and avoid using contaminated areas for agricultural purposes before the soil treatment process. Inductivity Coupled Plasma Mass Spectrometry (ICP-MS) technique was used to determine the concentrations of these elements, and the results showed that there is a high concentration of Cr, Ni, Mo, and Mn in the soil of the study area, which exceeded the international levels compared with other elements (Co, Th, U, and
... Show MoreTo assess the environmental pollution of the soil at north Baiji City, the concentration of As, Se, Cr, Co, Cu, Cd, Sb, Mn, Mo, Ni, Pb, V, U, Sr, Ba, Ag, Rb, Li, Sn, Bi, Tl and Zn were determined in 18 sites. Results showed that the range concentrations of metal in mg/kg were Mo (0.84-2.15), Cu (17.62-78.77), Pb (9.89-19.19), Zn (39.5-374.7), Ag (0.064-0.14), Ni (90.7-210), Co (12.8-26.6), Mn (407-863), As (4-7.1), Cd (0.18-0.37), Sb (0.38-0.77), Bi (0.06-0.17), V (74-281), Cr (128-287), Li (15.3-24.4), Tl (0.14-0.24), Sn (0.6-1.7), Rb (28-51.2), U (1.2-1.5), Se (0.3-0.6), Ba (173-310), Sr (218-1270). Based on enrichment factor (EF) of trace elements, Mo, Cu, Pb, Mn, Bi, U, V, Li, Sn, Rb, Ba and Tl were showed deficiency to minimal enric
... Show MoreCharacterized Iraq, being one of the oldest countries where oil was discovered in the Middle East since 1927, and possess a vast oil reserves. In addition, the production and marketing of Iraqi oil continued since 1934 and until the present time. Over the past eight decades, the range of economic benefit of the financial Iraq’s oil resources varied according to the applicable forms of investments in the oil sector in Iraq.
This research included a study
... Show MorePotentiostatic polarization and weight loss methods have been used to investigate the corrosion behavior of carbon steel in sodium chloride solution at different concentrations (0.1, 0.4 and 0.6) M under the influence of temperatures ( 293, 298, 303, 308 and 313) K. The inhibition efficiency of the amoxicillin drug on carbon steel in 0.6 M NaCl has also been studied based on concentration and temperature. The corrosion rate showed that all salt concentrations ( NaCl solution) resulted in corrosion of carbon steel in varying ratio and 0.6 M of salt solution was the highest rate (50.46 g/m².d). The results also indicate that the rate of corrosion increases at a temperature of 313 K.. Potentiodynamic polarization studi
... Show MoreThe corrosion behavior of copper and carbon steel in 1M concentration of hydrochloric acid (HCl) and sulphuric acid (H2SO4) has been studied. The corrosion inhibition of copper and carbon steel in 1M concentration of hydrochloric acid (HCl) and sulphuric acid (H2SO4) by Ciprofloxacin has been investigated. Specimens were exposed in the acidic media for 7 hours and corrosion rates evaluated by using the weight loss method. The effect of temperature (from 283 ºK to 333 ºK), pH (from 1to 6), inhibitor concentration (10-4 to 10-2) has been studied. It was observed that sulphuric acid environment was most corrosive to the metals because of its oxidizing nature, followed by hydrochloric acid. The rate of metal dissolution increased with incre
... Show MoreIn this work the corrosion behavior of Ti-6Al-4V alloy was studied by using galvanostatic measurements at room temperature in different media which includ sodium chloride (food salt), sodium tartrate (presence in jellies, margarine, and sausage casings,etc.), sodium oxalate (presence in fruits, vegetables,etc.), acetic acid (presence in vinegar), phosphoric acid (presence in drink), sodium carbonate (presence in 7up drink,etc.), and sodium hydroxide in order to compare.
Corrosion parameters were interpreted in th
... Show MoreA potentiostatic study of the behaviour of Inconel (600) in molar sulphuric acid has been carried out over the temperature range 293-313 K. Values have been established for the potentials and current densities of the corrosion, active-passive transition, passivity and transpassive states. For corrosion, the current density (ic) and potential (Ec) have been determined from well-defined Tafel lines. The potential and current density prior to the commencement of passivity have been obtained corresponding respectively to the critical potential (Ecr( and to the current density (icr) for the active-passive transition state. The passive range was defined by the respective potentials and current densities for passive film formation and dissolutio
... Show MoreThe present study was conducted to evaluate the effect of different inhibitors on the corrosion rate of aluminum in 50% (v/v) ethylene glycol solution at 80°C and pH 8.0 in which the electrochemical technique of linear sweep voltammetry was employed to characterize each inhibitor function and to calculate the corrosion rate from Tafel plots generated by a computer assisted potentiostat.
It is found that both sodium dichromate and borax reduces the corrosion rate by polarizing the anodic polarization curve while sodium phosphate, potassium phosphate, and sodium benzoate reduces the corrosion rate by polarizing both the anodic and cathodic polarization curve.
When inhibitor concentration increases from I g/l up
... Show More