Detecting protein complexes in protein-protein interaction (PPI) networks is a challenging problem in computational biology. To uncover a PPI network into a complex structure, different meta-heuristic algorithms have been proposed in the literature. Unfortunately, many of such methods, including evolutionary algorithms (EAs), are based solely on the topological information of the network rather than on biological information. Despite the effectiveness of EAs over heuristic methods, more inherent biological properties of proteins are rarely investigated and exploited in these approaches. In this paper, we proposed an EA with a new mutation operator for complex detection problems. The proposed mutation operator is formulated under four expressions depending on the type of gene sub-ontology. To demonstrate the performance of the proposed evolutionary based complex detection algorithm, the Saccharomyces Cerevisiae (yeast) PPI network is used in the evaluation. The results reveal that the proposed algorithm achieves more accurate complex structures than the counterpart heuristic algorithms and the canonical evolutionary algorithm based on the topological-aware mutation operator.
Polycystic syndrome (PCOS) is a considerable infertility disorder in adolescents and adult women in reproductive age. Obesity is a vigorous risk factor related to POCS. This study aims to evaluate the association of obesity and PCOS by investigating several parameters including: anthropological, biochemical (lipid profile, fasting blood sugar, glucose tolerance test, and hormone levels (LH, FSH, LH/FSH ratio, Estradiol2 and Testosterone),and genetic parameters (Fat mass and Obesity associated gene (FTO) polymorphism at rs17817449) in 63 obese and non-obese PCOS women. The biochemical tests were investigated by colorimetric methods while FTO gene polymorp
... Show MorePolycystic syndrome (PCOS) is a considerable infertility disorder in adolescents and adult women in reproductive age. Obesity is a vigorous risk factor related to POCS. This study aims to evaluate the association of obesity and PCOS by investigating several parameters including: anthropological, biochemical (lipid profile, fasting blood sugar, glucose tolerance test, and hormone levels (LH, FSH, LH/FSH ratio, Estradiol2 and Testosterone),and genetic parameters (Fat mass and Obesity associated gene (FTO) polymorphism at rs17817449) in 63 obese and non-obese PCOS women. The biochemical tests were investigated by colorimetric methods while FTO gene polymorphism was detected by PCR–RFLP. Lipid profile, F
... Show MorePolycystic syndrome (PCOS) is a considerable infertility disorder in adolescents and adult women in reproductive age. Obesity is a vigorous risk factor related to POCS. This study aims to evaluate the association of obesity and PCOS by investigating several parameters including: anthropological, biochemical (lipid profile, fasting blood sugar, glucose tolerance test, and hormone levels (LH, FSH, LH/FSH ratio, Estradiol2 and Testosterone),and genetic parameters (Fat mass and Obesity associated gene (FTO) polymorphism at rs17817449) in 63 obese and non-obese PCOS women. The biochemical tests were investigated by colorimetric methods while FTO gene polymorphism was detected by PCR–RFLP. Lipid profile, F
... Show MoreAnkylosing spondylitis is a complex debilitating disease because its pathogenesis is not clear. This study aims at detecting some pathogenesis factors that lead to induce the disease. Chlamydia pneumoniae is one of these pathogenesis factors which acts as a triggering factor for the disease. The study groups included forty Iraqi Ankylosing spondylitis patients and forty healthy persons as a control group. Immunological and molecular examinations were done to detect Chlamydia. pneumoniae in AS group. The immunological results were performed by Enzyme-Linked Immunosorbent Assay (ELISA) to detect anti-IgG and anti-IgM antibodies of C. pneumoniae revealed that five of forty AS patients' samples (12.5%) were positive for anti-IgG and IgM C. pneu
... Show MoreIn this research the performance of 5G mobile system is evaluated through the Ergodic capacity metric. Today, in any wireless communication system, many parameters have a significant role on system performance. Three main parameters are of concern here; the source power, number of antennas, and transmitter-receiver distance. User equipment’s (UEs) with equal and non-equal powers are used to evaluate the system performance in addition to using different antenna techniques to demonstrate the differences between SISO, MIMO, and massive MIMO. Using two mobile stations (MS) with different distances from the base station (BS), resulted in showing how using massive MIMO system will improve the performance than the standar
... Show MoreThe thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and
... Show MorePartial shading is one of the problems that affects the power production and the efficiency of photovoltaic module. A series of experimental work have been done of partial shading of monocrystalline PV module; 50W, Isc: 3.1A, Voc: 22V with 36 cells in series is achieved. Non-linear power output responses of the module are observed by applying various cases of partial shading (vertical and horizontal shading of solar cells in the module). Shading a single cell (corner cell) has the greatest impact on output energy. Horizontal shading or vertical shading reduced the power from 41W to 18W at constant solar radiation 1000W/m2 and steady state condition. Vertical blocking a column
... Show More