Preferred Language
Articles
/
ExcQs44BVTCNdQwCBVcS
Wideband sound absorption of a double-layer microperforated panel with inhomogeneous perforation
...Show More Authors

Micro-perforated panel (MPP) absorber is increasingly gaining popularity as an alternative sound absorber in buildings compared to the well-known synthetic porous materials. A single MPP has a typical feature of a Helmholtz resonator with a high amplitude of absorption but a narrow absorption frequency bandwidth. To improve the bandwidth, a single MPP can be cascaded with another single MPP to form a double-layer MPP. This paper proposes the introduction of inhomogeneous perforation in the double-layer MPP system (DL-iMPP) to enhance the absorption bandwidth of a double-layer MPP. Mathematical models are proposed using the equivalent electrical circuit model and are validated with experiments with good agreement. It is revealed that the DL-iMPP produces a wider half-absorption bandwidth compared to the conventional homogeneous double-layer MPP. The absorption bandwidth to higher frequencies can be effectively controlled by reducing the air cavity between the iMPPs and to the lower frequencies by increasing the back cavity depth at the second layer.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Apr 01 2021
Journal Name
Neuroquantology
Finding Most Stable Isobar for Nuclides with Mass Number (165- 175) against Beta Decay
...Show More Authors

In the beta decay process, a neutron converts into a proton, or vice versa, so the atom in this process changes to a more stable isobar. Bethe-Weizsäcker used a quasi-experimental formula in the present study to find the most stable isobar for isobaric groups of mass nuclides (A=165-175). In a group of isobars, there are two methods of calculating the most stable isobar. The most stable isobar represents the lowest parabola value by calculating the binding energy value (B.E) for each nuclide in this family, and then drawing these binding energy values as a function of the atomic number (Z) in order to obtain the mass parabolas, the second method is by calculating the atomic number value of the most stable isobar (ZA). The results show

... Show More
Publication Date
Wed Jan 30 2019
Journal Name
Journal Of The College Of Education For Women
Peripheral Perception And its Relation With The Need for Cognition for The University Students
...Show More Authors

The most important topic for psychologist generally is factor of education and it's active tools because learning needs active perception for stimulus that recived by the educator and give it avalue and meaning , Need for cognition is
very important in the various daily fields of life , especially in learning and teaching and the academy work , it help with shifting the learning level for people , and icreas the intense and challenge between them
The research endeavored to achieve the following aim :
1- Measuring the level of peripheral perception for the university student .
2- Measuring the level of need for cognition for the university student .
3- Measuring the level of peripheral perception for the university student

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Educational And Psychological Researches
Guilt and its relationship with the self-awareness Educational research Open Educational College Students
...Show More Authors

Targeted current research study of the relationship between guilt and self-consciousness and consisted of the research community of students from the open educational college, as has been selected students in the Department of Counseling and psychological science department and the researcher used guilt, prepared Scale (Ansari, 2003), and the measure of selfawareness prepared (Shammari 0.2000), and extracted his Alsekoumtria characteristics, Fastkhrjt alternatives after a presentation to a group of experts and specialists in the field of psychological counseling psychology, education, science and psychological validity and reliability Alvakronbach manner and retesting reaching reliability coefficient of guilt ((0.85) and awarenes

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Advanced Computer Science And Applications
Face Detection and Recognition Using Viola-Jones with PCA-LDA and Square Euclidean Distance
...Show More Authors

View Publication
Crossref (27)
Crossref
Publication Date
Mon Jan 04 2021
Journal Name
Multimedia Tools And Applications
Attention enhancement system for college students with brain biofeedback signals based on virtual reality
...Show More Authors

View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Feb 09 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between powerful Waterpik flosser with dental floss as an adjunct to tooth brushing
...Show More Authors

Background: Removing dental plaque is important to maintain a good oral hygiene and prevent periodontal disease; this could not be accomplished by the use of toothbrush alone, it needs the help of interdental aids or intra-oral irrigator devices. The aim of this study was to compare the effect of using Waterpik flosser as adjunct to tooth brushing than using the dental floss with the brushing. Materials and methods: A single blind, six weeks study included 45 subjects divided into three groups of 15 subjects at each group. Group B (brushing) was instructed to use the toothbrush only, group BF (brushing & flossing) was instructed to use dental floss and tooth brushing while group BW (brushing and Waterpik flosser) was instructed to use Water

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 04 2022
Journal Name
Journal Of Optics
Coreless optical fiber for hemoglobin (HB) sensing with bilayer based on surface plasmon resonance
...Show More Authors

In this work, an optical fiber biomedical sensor for detecting the ratio of the hemoglobin in the blood is presented. A surface plasmon resonance (SPR)-based coreless optical fiber was developed and implemented using single- and multi-mode optical fibers. The sensor is also utilized to evaluate refractive indices and concentrations of hemoglobin in blood samples, with 40 nm thickness of (20 nm Au and 20 nm Ag) to increase the sensitivity. It is found in practice that when the sensitive refractive index increases, the resonant wavelength increases due to the decrease in energy.

View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Biochemical Study on Anti Thyroid Peroxidase in Type 2 Diabetic patients with thyroid disorders
...Show More Authors

Type 2 diabetes mellitus (T2DM) is the most frequent endocrinal disease commonly associated with thyroid disorders .The study is conducted at the Specialized Center for Endocrinology and Diabetes in Baghdad ,during December 2014 up to October 2015.This study was done to investigate the prevalence of anti- thyroid peroxidase (Anti-TPO) antibody in patients suffered from type 2 diabetes with thyroid disorders .The study groups included a total number of 80 subjects consisting of 60 type 2 diabetic patients divided into 20 hyperthyroidism subjects (group 1) ,20 hypothyroidism subjects (group 2), 20 euthyroidism subjects (group 3) and 20 healthy controls (group 4) . The fasting blood samples were analyzed for (T3,T4,TSH) by using Vitek Immuno d

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 19 2020
Journal Name
Applied Water Science
Spiral path three phase fluidized bed reactor for treating wastewater contaminated with engine oil
...Show More Authors
Abstract<p>In this study, a new type of circulating three-phase fluidized bed reactor was conducted by adding a spiral path and was named as spiral three-phase fluidized bed reactor (TPFB-S) to investigate the possibility for removing engine oil (virgin and waste form) from synthetic wastewater by using Ricinus communis (RC) leaves natural and activated by KOH. The biosorption process was conducted by changing particle diameter in the range 150–300 and 300–600 µm, liquid flow rate in the range 2.5–4.5 L/min and gas flow rate in range of 0–1 L/min, while other parameters initial oil emulsion concentration, pH, adsorbent concentration, agitation speed and contact time were kept constant at 2000 mg/L, 2,</p> ... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Ieee/acm Transactions On Audio, Speech, And Language Processing
Underdetermined Convolutive Source Separation Using GEM-MU With Variational Approximated Optimum Model Order NMF2D
...Show More Authors

View Publication
Scopus (25)
Crossref (17)
Scopus Clarivate Crossref