SnS nanobelt thin films were deposited on glass substrates in acidic solution by chemical bath deposition (CBD) method. The belt-like morphologies of as-deposited SnS thin films were characterized by scanning electron microscope (SEM) and transmission electron microscopy (TEM). X-ray diffraction (XRD) and Raman measurements were carried out to confirm the crystal structures and phase purities of SnS nanobelt thin films. The morphologies and phase purities of SnS thin films were influenced greatly by the tin and sulfur precursors. The bandgaps of SnS nanobelts were determined to be 1.39–1.41 eV by UV–vis absorption and photoluminescence (PL) spectra. Current-voltage ((I-V)) and current-time ((I-T)) characteristics were studied to demonstrate the photoelectric performances of SnS nanobelt thin films.
In this work 5-methylene-yl - (2-methy –oxazole-4-one) (1H) imidazole (1) were synthesized from the reaction of L-Histidine with acetic anhydride and which converted to the of 5-methylene-yl-(2-methyl 3-amino imidazole-4-one)-1H-imidazole (2) by reaction with hydrazine hydrate. Schiff bases (3-6) were synthesized from the reaction of compound (2) with different aromatic aldehyde. Reaction of compounds (3-6) with chloroacetyl chloride gives azetidinone one derivatives (7-10). These compounds were characterized by FT-IR and some of them with 1H-NMR and 13C-NMR spectroscopy.
This study included nine patients with inactive carrier states of HBV and 14 healthy control groups. The number and the percentage of T-lymphocyte (CD3+ Cells) in the peripheral blood of these groups showed no significant difference. Similar trend was observed when number and percentages of T helper cells (CD4+ cells) and T cytotoxic lymphocytes (CD8+ cells). Moreover, no significant difference in CD4+ /CD8+ cells ratio (P > 0.05) in peripheral blood of patients with inactive carrier state of HBV as compared with healthy control group. The levels of total serum bilirubin (TSB) concentration and alanine aminotransferase (ALT) activity were similar to control group. The levels of immunoglobulin concentration (IgG and IgM) in patients g
... Show MoreHealth and environmental factors as well as operational difficulties are major challenges facing the development of an anaerobic digestion process. Some of these problems relate to the use of sludge collected from primary and secondary clarifier units in wastewater treatment plants for laboratory purposes.
The present study addresses the preparation of sludge for laboratory purposes by using a mixture that consists of the digested sludge, which is less pathogenic, compared to the collected sludge from the primary or secondary clarifier, and food wastes. The sludge has been tested experimentally for 19 and 32 days under mesophilic conditions. The results show a steady methane production rate from the anaerobic dig
... Show MoreThis study investigated the feasibility of anaerobic co-digestion of giant reed (GR) inoculated with waste manure as a co-substrate for biogas production. The performance of co-digestion was evaluated in 4 anaerobic digesters operated in batch mode at different conditions. The effects of alkali pretreatment with NaOH (4% w/v) solution, inoculum type, and thermal condition were studied. The results demonstrated that the alkali-pretreatment of GR enhanced the biogas generation by about 15% at mesophilic conditions. Thermophilic conditions enhanced the biogas recovery from both alkali-free and alkali pretreated GR by 15% and 127%, respectively. The kinetic study of the co-digestion process of GR for biogas recovery suggeste
... Show MoreThis study aims to analyze spectra in real-time for λ Draconids, σ Hydrids, μ Virginid, and one sporadic meteor using spectroscopic chemical analysis and diagnose plasma parameters. Good-resolution spectroscopy and a CCD camera for meteor observation were used concurrently to examine the ablation spectra of these meteorites in situ. The Boltzmann and Lorentz methods were then used to determine the temperature and density of electrons, the length of Debye, and the frequency of plasma. Furthermore, spectra data can be analyzed and compared to data from other sources. Spectrum tests can be utilized to identify the chemical structure of meteorites' plasma.
An electrochemical sensor based on manganese dioxide nanorodMnO2and Graphene oxide (GO) functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (FGO)/MnO2Nanocompositewas developed for voltammetric determination of Tetracycline (TET).The working electrode WE of SPCE was modified bya drop casting method. X-ray powder diffractometer (XRD), scanning electron microscopy (SEM) and FT-IR were employed to characterize the synthesized FGO/MnO2. The determination of TET at the modified electrode was studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in the phosphate buffer solution (PBS).TET show sharp increase in the oxidation peaks in the pH 2.Voltammetric characteristics of TET (Epa, Ipa) were estimate
... Show MoreAmong a collection of ground beetles from Iraq the new species Acinopus euphraticus was designated and described here. The erection of this new species was mainly built on external features and the description of male genitalia.
The Islamic Issue did not rise the “widespread arguments” in contemporary times, just as the issue of applying Islamic Law. Just as the Islamic forces used this purpose, or employed it during their march to reach to power by adopting the sacred as motivation towered the power, or control the governance. However, the reality show that this goal remained within the boundaries of slogans in the sense of a teleological slogan, and did not go beyond the limits of advocacy or arrangement as the primary source of legislation with differences of teleological reasoning, in a manner that reflected an intellectual problem about the validity of the use of this concept or the ability to apply and enforce the law in today's world, to impose
... Show MoreIn petroleum industry, the early knowledge of “pore pressure gradient” is the basis in well design and the extraction of these information is more direct when the pore pressure gradient is equal to normal gradient; however, this matter will be more complex if it deviate from that limit which is called “abnormal pore pressure”, if this variable does not put in consideration, then many drilling problems will occur might lead to entire hole loss. To estimate the pore pressure gradient there are several methods, in this study; Eaton method’s is selected to extract the underground pressure program using drilling data (normalized rate of penetration) and logs data (sonic and density log). The results shows that an abnormal high press
... Show More