Rheumatoid arthritis is an autoimmune diseasecharacterized by chronic inflammationthat affects joints and cartilage. Bone complications such asRA-relatedosteoporosis are one of the most extra-articular manifestations. Many inflammatory mediators are released during RA disease pathophysiology; these mediators stimulate osteoclast genesis of bone by direct effects on RANKL and OPG. The study aimedto measure RANKL, OPG in RA patients treated with Etanercept only and other groups treated with Methotrexate onlyat baseline and after three months to evaluate bone state. An observational case-control prospective study was done on 30 RA patients who received MTX, 30 RA patients who received ETN, and 30 healthy,age-matched control groups. The level of RANKL and OPG was measured at baseline and after three months of therapy by immunoenzymatically assay (ELISA). The results were tabulated and statistically analyzed usingthe statistical package for social science. The result demonstrated that RANKL level had a positive correlation with age and disease duration in contrast to OPG level showed a negative correlation with age and duration of disease. In the patients group treated with MTX at baseline, the RANKL level was significantly higher (181.336±65.583) than post-therapy (166.097±69.229), while the OPG level at baseline significantly lower (594.398±133.238) than post therapy (614.499±150.879). In ETN treated patients, the level of RANKL in baseline was significantly higher than (231.247±73.134) RANKL level post-therapy (200.363±76.807), while OPG level in baseline waslower (463.263±96.392) than post therapy (503.608±107.692). The study demonstrated in baseline RANKL/OPG ratio significant higher (0.4340±0.234) than post therapy (0.3690±0.222). All RA patients had or were at high risk for osteoporosis.Both Etanarcept and methotrexate produce insignificant differences on OPG and RANKL levels, in the same time this biomarkers are not good indicators for bone state.
This paper presents an experimental study of cooling photovoltaic (PV) panels using evaporative cooling. Underground (geothermal energy) water used to extract heat from it during cooling and cleaning of PV panels. An experimental test rig was constructed and tested under hot and dusty climate conditions in Baghdad. An active cooling system was used with auxiliary an underground water tank to provide cold water as a coolant over both PV surfaces to reduce its temperature. The cellulose pad has been arranged on the back surface and sprays cooling on the front side. Two identical PV panels modules used: without cooling and evaporative water cooling. The experiments are comprised of four cases: Case (I): backside cooling, Ca
... Show MoreThis studies deals with investigated the potential of a Iraqi bentonite clay for the adsorption of bromo phenol red dye from contaminated water. Impulse adsorption experiments were performed. The contact time influence of initial dye concentration, temperature, pH, ionic strength, partical size adsorbent and adsorbent dosage on bromo phenol red adsorption are investigated in a series of batch adsorption experiments. Adsorption equilibrium data were analyzed and described by the Freundlich, Langmuir and temkin isotherms equations. Thermodynamic parameters inclusive the Gibbs free energy (∆G•), enthalpy (∆H•), and entropy (∆S•), were also calculated. These parameters specified tha
... Show MoreThis study was designed for isolation of some fungi that caused sub clinical mastitis in cow milk in AL-anbar governorate in Iraq . Total number of 100 milk samples were collected from 25 cow in AL- Falluja city , by using of California mastitis test 45% of milk samples were infected with sub clinical mastitis ,while 55% of milk samples were negative for California mastitis test. The results showed of fungal isolation of milk samples which were positive for California mastitis test, recording 19 isolates of different types of fungi : Aspergillus fumigatus2.2% , Aspergillus niger 4.4% , Candida albicans 26.6% , Blastomced dermetitidis% 4.4 and Geotrichum candidum4.4%. The isolation of these types of fungi, may be attributed to many factor
... Show MoreDevelopments are carried out to enhance the performance of vertical axis wind turbines (VAWT). This paper studies the performance of the ducted wind turbine with convergent duct (DAWT). Basically, the duct technique is utilized to provide the desired wind velocity facing the turbine. Methodology was developed to estimate the decisive performance parameter and to present the effect of the convergent duct with different inlet angles. The ducted wind turbine was analyzed and simulated using MATLAB software and numerically using ANSYS-Fluent 17.2. Result of both approaches were presented and showed good closeness for the two cases of covering angles 12 and 20 respectively. Results also showed that the convergent duct with an inlet angl
... Show MorePoetic objects may go towards a specific purpose and dissolve and interact with them to produce
A purpose characterized by the title but belongs to the U from afar.
The yarn goes towards praise with a purely horizontal relationship that mentions virtues but crowns them towards women.
In lamentation remember the virtues but crown them towards the dead.
In wisdom remember the virtues but crown them towards time.
In the description remember the virtues but crown them towards nature. All objects are inline
Horizontal We will prove this in the axes of research has required the plan to be a blind, five
The preamble, a brief overview of the life of Dabal All Khuzaie and the works and poets of the first axis
The direction
The inhibitive action of a blend of sodium nitrite/sodium hexametaphosphate (SN+SHMP) on corrosion of carbon steel in simulated cooling water systems (CWS) has been investigated by weight loss and electrochemical polarization technique. The effect of temperature, velocity, and salts concentrations on corrosion of carbon steel were studied in the absence and presence of mixed inhibiting blend. Also the effect of inhibitors blend concentrations (SN+SHMP), temperatures, and rotational velocity, i.e., Reynolds number (Re) on corrosion rate of carbon steel were investigated using Second-order Rotatable Design (Box-Wilson Design) in performing weight loss and corrosion potential approach. Electrochemical polarization measurements
... Show More<span lang="EN-GB">Transmitting the highest capacity throughput over the longest possible distance without any regeneration stage is an important goal of any long-haul optical network system. Accordingly, Polarization-Multiplexed Quadrature Phase-Shift-Keying (PM-QPSK) was introduced lately to achieve high bit-rate with relatively high spectral efficiency. Unfortunately, the required broad bandwidth of PM-QPSK increases the linear and nonlinear impairments in the physical layer of the optical fiber network. Increased attention has been spent to compensate for these impairments in the last years. In this paper, Single Mode Fiber (SMF), single channel, PM-QPSK transceiver was simulated, with a mix of optical and electrical (Digi
... Show MoreThis paper is carried out to detect the subsurface structures that have geological
and economical importance by interpreting the available reflection seismic data of
an area estimated to be about (740) km2. The Khashim Al-Ahmer structure is partial
of series structures of (Injana – Khashim Al-Ahmer – Mannsorya) from the (NW to
the SE), it is located within for deep faulted area. The component of the one
elongated dome of asymmetrical of structure which has(SW) limb more steeper than
the (NE) limb.Twenty three seismic sections had been interpreted for two seismic
surveys and the total length of all seismic lines is about (414.7) Km. Interpretation
of seismic data was focused on two reflectors (Fatha and Jeribi)
This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,
... Show More