Preferred Language
Articles
/
EBgtu5cBVTCNdQwCNJtt
Direct transplant of melanocytes from normal donor area into vitiligenous recipient area by intralesional injection of melanocytes using spade like needle technique
...Show More Authors

KE Sharquie, AA Noaimi, ZN Al-Khafaji…, Journal of Cosmetics, Dermatological Sciences and Applications, 2016 - Cited by 2

View Publication
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Investigation of Superhydrophobic/Hydrophobic Materials Properties Using Electrospinning Technique
...Show More Authors

     The aim of this research is to study the surface alteration characteristics and surface morphology of the superhydrophobic/hydrophobic nanocomposite coatings prepared by an electrospinning method to coat various materials such as glass and metal. This is considered as a low cost method of fabrication for polymer solutions of Polystyrene (PS), Polymethylmethacrylate (PMMA) and Silicone Rubber (RTV). Si were prepared in various wt% of composition for each solutions. Contact angle measurement, surface tension, viscosity, roughness tests were calculated for all specimens. SEM showed the morphology of the surfaces after coated. PS and PMMA showed superhydrophobic properties for metal substrate, while Si showed hydroph

... Show More
View Publication Preview PDF
Scopus (24)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
The effect of anode temperature on the Optical characteristic of Se films prepared by direct current planar magnetron sputtering
...Show More Authors

This work describes, selenium (Se) films were deposited on clean glass substrates by dc planar magnetron sputtering technique.The dependence of sputtering deposition rate of Se film deposited on pressure and DC power has been studied. The optimum argon pressure has range (4x10-1 -8x10-2 )mbar. The optical properties such as absorption coefficient (α) was determined using the absorbance and transmission measurement from UnicoUV-2102 PC spectrophotometer, at normal incidence of light in the wavelength range of 200-850 nm. And also we calculated optical constants(refractive index (n), dielectric constant (εi,r), and Extinction coefficient (κ) for selenium films.

View Publication Preview PDF
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and Antimicrobial Study of Possible Mutual Prodrugs of Amoxicillin and Metronidazole by Direct and Indirect Coupling through Spacer
...Show More Authors

Amoxicillin have been conjugated with metronidazole as possible mutual prodrug to get a wider spectrum of activity by acting on aerobic and anaerobic bacteria, have antifungal activity, to provide protection for beta lactam ring of amoxicillin and also to improve patient compliance as it given as a single dose therapy. The structures of the synthesized compound were confirmed and characterized using elemental microanalysis (CHN), IR and some physiochemical properties. Biological study was done by using  disc diffusion method against different bacterial strains which are , Staphylococcus aureus , Salmonella typhie , Pseudomonas aeruginosa , E. coli , Klebsiella pneumonia and fungi ( Candida albicans) . using nutrien

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Thymol Using Procaine Hydrochloride as a New Chromogenic Reagent
...Show More Authors

New, simple and sensitive batch and Flow-injecton spectrophotometric methods for the determination of Thymol in pure form and in mouth wash preparations have been proposed in this study. These methods were based on a diazotization and coupling reaction between Thymol and diazotized procaine HCl in alkaline medium to form an intense orange-red water-soluble dye that is stable and has a maximum absorption at 474 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 0.4-4.8 and 4-80 µg.ml-1 of Thymol, with detection limits of 0.072 and 1.807 µg.ml-1 of Thymol for batch and FIA methods respectively. The FIA procedure sample throughput was 80 h-1. All different chemical and physical e

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 31 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Extending the storage life of some fruits by using Pullulan produced from locally isolate Aureobasidium pullulans: Extending the storage life of some fruits by using Pullulan produced from locally isolate Aureobasidium pullulans
...Show More Authors

Six isolates of A. pullulans were collected from many sources including Hibiscus sabdariffa (Roselle), old Roofs of houses and bathroom surface that referred as Ap ros1, Ap or2, 3, 4 and Ap bs5, 6 respectively, all these isolates were identified based on morphological characteristics and nutritional physiology profiles, all were able to utilize various carbon and nitrogen sources such as glucose, xylose, sucrose, maltose, ammonium sulfate, ammonium nitrate and ammonium chloride, also they showed positive test for starch and amylase, while α-cellulose, ethanol, and methanol were could not be ass

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Relationship Between Nusselt and Reynolds Number in Direct Contact Heat Transfer by Condensation of Light Hydrocarbons in Water
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Apr 25 2012
Journal Name
Journal Of Chromatographic Science
Direct Acetylation and Determination of Chlorophenols in Aqueous Samples by Gas Chromatography Coupled with an Electron-Capture Detector
...Show More Authors

A method was developed that offers a rapid, simple and accurate technique for the determination of chlorophenols at trace levels in aqueous samples with very limited volumes of organic solvents. These compounds were acetylated, then preliminarily extracted with n-hexane. The enriched chlorophenols were directly analyzed using gas chromatography with an electron-capture detector. The detection limits were in the range of 0.001–0.005 mg/L, except for 2-chlorophenol, which was always above 0.013 mg/L. Relative standard deviation for the spiked water samples ranged from 2.2 to 6.1%, while relative recoveries were in the range of 67.1 to 101.3%.

View Publication
Scopus (15)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Mon Apr 17 2023
Journal Name
International Journal Of Veterinary Science And Medicine
Donor variability of ovine bone marrow derived mesenchymal stem cell - implications for cell therapy
...Show More Authors

View Publication Preview PDF
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun May 10 2015
Journal Name
Al-academy
The industrial design aesthetic and its relationship with the recipient: باسم قاسم الغبان، صلاح نوري الجيلاوي
...Show More Authors

The research problem lies in determining the beauty ranges between the receiver and the industrial product, The goal of the research, it is the definition of aesthetics in industrial design and its relation to the receiver, and the researcher outcome several conclusions of the, the most important was: 1. The role of accumulated experience, and their interaction with the vision of the artwork in achieving aesthetic perception and levels of artistic and aesthetic values and by the level of growth this taste of the recipient. 2. There are interactive and close relationship be the primary means for the integration of functional and aesthetic meaning the designer meant to get it to the receiver.

 

View Publication Preview PDF
Crossref
Publication Date
Mon Sep 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Design and Simulation of GaussianFSK Transmitter in UHF Band Using Direct Modulation of ΣΔ Modulator Fractional-N Synthesizer
...Show More Authors

This research involves design and simulation of GaussianFSK transmitter in UHF band using direct modulation of ΣΔ  fractional-N synthesizer with the following specifications:

Frequency range (869.9– 900.4) MHz, data rate 150kbps, channel spacing (500 kHz), Switching time 1 µs, & phase noise @10 kHz = -85dBc.

New circuit techniques have been sought to allow increased integration of radio transmitters and receivers, along with new radio architectures that take advantage of such techniques. Characteristics such as low power operation, small size, and low cost have become the dominant design criteria by which these systems are judged.

A direct modulation by ΣΔ  fractional-N synthesizer is proposed

... Show More
View Publication Preview PDF