Background: Health information systems in most countries are inadequate in providing the needed management support and the current health information systems are therefore widely seen as management obstacles rather than as tools,Objectives: the current study is an attempt to assess the behavioral and organizational determinants of health information system performance in Iraq.Methods: A cross-sectional study was conducted by interviewed a total of 189 respondents selected from six Iraqi governorates. The Organizational and Behavioral Assessment Tool was used to measure the behavioral and organizational determinants of health information system performance, it is one of the PRISM package tools that are used to assess the health informatio
... Show MoreThe present study aimed to evaluate the levels of total immunoglobulin E and percentage count of eosinophil in some of allergic disease. Blood sample collected from 210 patients (110 female, 100 male) with allergic disease (allergic asthma, allergic rhinitis, and urticaria) their age between 10-70 years and 50 healthy control their age between 23-52 years. A highly significant (P<0.01) increase in the mean serum total IgE in patients with asthma (503.54 ± 63.49 IU/ml), Allergic rhinitis (442.77 ± 95.76 IU/ml) and urticaria (489.53 ± 69.68 IU/ml) as a compared with healthy controls (23.67 ± 5.81 IU/ml).There was a significant difference in percentage count of eosinophil in patients groups allergic asthma 4.37 ± 0.52% ,allergic rhinitis
... Show MoreNano crystalline copper sulphide (Cu2S) thin films pure and 3% Bi doped were deposited on glass substrate by thermal evaporation technique of thickness 400±20 nm under a vacuum of ~ 2 × 10− 5 mbar to study the influence of annealing temperatures ( as-deposited, and 573) K on structural, surface morphology and optical properties of (Cu2S and Cu2S:3%Bi). (XRD) X-ray diffraction analysis showed (Cu2S and Cu2S:3%Bi) films before and after annealing are polycrystalline and hexagonal structure. AFM measurement approves that (Cu2S and Cu2S:3%Bi) films were Nano crystalline with grain size of (105.05-158.12) nm. The optical properties exhibits good optical absorption for Cu2S:3%Bi films. Decreased of optical band gap from 2.25 to 2 eV after dop
... Show MoreObjective(s): To identify the relationship between demographic characteristics of patients with renal
failure and to find out the relationship between some risk factors like (family history, alcohol drinking,
smoking and chronic disease) with renal failure patients.
Methodology: Case control study design was carried out in order to achieve the objectives of the
study by using the assessment technique in Baghdad teaching hospital from March 5
th, 2017 to October
10th
, 2017, The sample was (cases & control) sample, present study include 200 cases, 100 was case
study the patient who entered in Baghdad teaching hospital, while another 100 was control study. The
data was collected by interview questionnaire inc
In this study miconazole nitrate was formulated as topically applied emulgel; different formulas were prepared using sodium carboxymethylcellulose (SCMC) and carboxypolymethylene (carbomer 941) as gelling agents. The influence of type of gelling agent and concentration of both oil phase and emulsifying agent on drug release was studied and compared with commercially available miconazole nitrate cream (Mecozalen®). The results of in vitro release showed that SCMC emulgel bases gave better release than carbomer 941 bases and the release of drug increase from both bases as a function of increasing the concentration of emulisifying agent. The oil phase had retardation effect when
... Show MoreThe sensors based on Nickel oxide doped chromic oxide (NiO: Cr2O3) nanoparticals were fabricated using thick-film screen printing of sol-gel grown powders. The structural, morphological investigations were carried out using XRD, AFM, and FESEM. Furthermore, the gas responsivity were evaluated towards the NH3 and NO2 gas. The NiO0.10: Cr2O3 nanoparticles exhibited excellent response of 95 % at 100oC and better selectivity towards NH3 with low response and recovery time as compared to pure Cr2O3 and can stand as reliable sensor element for NH3 sensor related applications.