Image pattern classification is considered a significant step for image and video processing.Although various image pattern algorithms have been proposed so far that achieved adequate classification,achieving higher accuracy while reducing the computation time remains challenging to date. A robust imagepattern classification method is essential to obtain the desired accuracy. This method can be accuratelyclassify image blocks into plain, edge, and texture (PET) using an efficient feature extraction mechanism.Moreover, to date, most of the existing studies are focused on evaluating their methods based on specificorthogonal moments, which limits the understanding of their potential application to various DiscreteOrthogonal Moments (DOMs). Therefore, finding a fast PET classification method that accurately clas-sify image pattern is crucial. To this end, this paper proposes a new scheme for accurate and fast imagepattern classification using an efficient DOM. To reduce the computational complexity of feature extraction,an election mechanism is proposed to reduce the number of processed block patterns. In addition, supportvector machine is used to classify the extracted features for different block patterns. The proposed scheme isevaluated by comparing the accuracy of the proposed method with the accuracy achieved by state-of-the-artmethods. In addition, we compare the performance of the proposed method based on different DOMs toget the robust one. The results show that the proposed method achieves the highest classification accuracycompared with the existing methods in all the scenarios considered
Lasmiditan (LAS) was formulated as a nanoemulsion based in situ gel (NEIG)with the aim of improving its oral bioavailability via application intranasally. The solubility of LAS in oils, emulsifiers, and co-emulsifiers was determined to identify nanoemulsion (NE)components. Phase diagrams were constructed to identify the area of nanoemulsification. LAS NE was formulated using the spontaneous nanoemulsification method. Four NEs (F19, F24, F31, and F34) containing 7-15 % oleic acid (OA) as an oily phase, 40-55% labrasol (LR), and transcutol (TC) as emulsifier mixture at (1:1), (2:1), (3:1), and (1:2) ratio with 30-53 % (w/w) aqueous phase, having suitable optical transparency of 95–98%, globule size of 104-140 nm and polydisper
... Show MoreAbstract:
This research aims to apply the Performance Focused Activity Based Costing System in the consultant office of Al-Khwarizmi College of Engineering at the University of Technology for the purpose of measuring the cost of consulting services provided by these offices in order to reduce costs and their reflection in achieving profits. For the purpose of calculating costs accurately, and to test the hypothesis of the research, the research was applied in the office of the consultant of the College of Engineering Al-Khwarizm - University of Baghdad through the financial statement
... Show MoreThe current study aims to develop a proposed educational program based on augmented reality (AR) technology, in addition to assessing its effectiveness in developing research and historical imagination skills of the Humanities Track's female students at the secondary stage, as well as assessing the correlative and predictive relationships between the amount of growth for the two dependent variables. To achieve this, a secondary school in the city of Makkah Al-Mukarramah was chosen, and an available random sample of (30) female students from the study population was selected. The quasi-experimental approach was followed by this study, particularly one group design. In addition, two tools were used to collect study data, namely: a test of
... Show MoreBackground: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement,
... Show MoreAbstract:
Typological analysis about the negation marker in different languages is one of the fields of research that has attracted much attention. In Persian language, this constituent has been analysed from different aspects. This study aimed to analyse different aspects of negation marker in the adjectives, the noun phrases and the verb phrases based on typological analysis. Many studies have been revealed that the negation in adjectives has shown lexically and morphologically. In the noun phrases, /hich/ has used as a negative marker necessarily marking the verb phrase as negative too. In the verb phrases, negation occurs morphologically by the addition of the prefix /n
... Show MoreThe purpose of this study was to find out the connection between the water parameters that were examined in the laboratory and the water index acquired from the examination of the satellite image of the study area. This was accomplished by analysing the Landsat-8 satellite picture results as well as the geographic information system (GIS). The primary goal of this study is to develop a model for the chemical and physical characteristics of the Al-Abbasia River in Al-Najaf Al-Ashraf Governorate. The water parameters employed in this investigation are as follows: (PH, EC, TDS, TSS, Na, Mg, K, SO4, Cl, and NO3). To collect the samples, ten sampling locations were identified, and the satellite image was obtained on the
... Show MoreA novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.