Preferred Language
Articles
/
EBZ7oooBVTCNdQwC5qJW
Tubular Magnetic Shielding Scan (TMSS): A New Technique for Molecular Space Exploration. (i) The Case of Aromaticity of Benzene and [<i>n</i>]Paracyclophanes
...Show More Authors

Both traditional and novel techniques were employed in this work for magnetic shielding evaluation to shed new light on the magnetic and aromaticity properties of benzene and 12 [n]paracyclophanes with n = 3–14. Density functional theory (DFT) with the B3LYP functional and all-electron Jorge-ATZP and x2c-TZVPPall-s basis sets was utilized for geometry optimization and magnetic shielding calculations, respectively. Additionally, the 6-311+G(d,p) basis set was incorporated for the purpose of comparing the magnetic shielding results. In addition to traditional evaluations such as NICS/NICSzz-Scan, and 2D-3D σiso(r)/σzz(r) maps, two new techniques were implemented: bendable grids (BGs) and cylindrical grids (CGs) of ghost atoms (Bqs). BGs allow for the recording of magnetic shielding from the bent ring levels of [n]pCPs, while CGs provide tubular magnetic shielding scan (TMSS) maps detailing the magnetic shielding from a cylindrical region above and below the ring frame. Our findings suggest that smaller [n]pCPs with n < 6 exhibit deviations in the magnetic shielding above and below the ring, indicating a broken electron delocalization under the ring. In contrast, larger [n]pCPs tend to behave similarly to benzene in terms of magnetic shielding. Moreover, we found that shorter polymethylene chains of [n]pCPs exhibit significantly higher magnetic shielding interactions with the ring. Both of the above techniques offer new and promising tools for characterizing nonplanar aromatic compounds, thereby contributing to a deeper understanding of their magnetic and electronic properties.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Aug 30 2018
Journal Name
Journal Of Engineering
Accuracy Assessment of Various Resolutions Digital Cameras For Close Range Photogrammetry Applications
...Show More Authors

Due to the great evolution in digital commercial cameras, several studies have addressed the using of such cameras in different civil and close-range applications such as 3D models generation. However, previous studies have not discussed a precise relationship between a camera resolution and the accuracy of the models generated based on images of this camera. Therefore the current study aims to evaluate the accuracy of the derived 3D buildings models captured by different resolution cameras. The digital photogrammetric methods were devoted to derive 3D models using the data of various resolution cameras and analyze their accuracies. This investigation involves selecting three different resolution cameras (low, medium and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Feb 05 2021
Journal Name
Scientific Reports
Green Nanotechnology of MGF-AuNPs for Immunomodulatory Intervention in Prostate Cancer Therapy
...Show More Authors
Abstract<p>Men with castration-resistant prostate cancer (CRPC) face poor prognosis and increased risk of treatment-incurred adverse effects resulting in one of the highest mortalities among patient population globally. Immune cells act as double-edged sword depending on the tumor microenvironment, which leads to increased infiltration of pro-tumor (M2) macrophages. Development of new immunomodulatory therapeutic agents capable of targeting the tumor microenvironment, and hence orchestrating the differentiation of pro-tumor M2 macrophages to anti-tumor M1, would substantially improve treatment outcomes of CRPC patients. We report, herein, Mangiferin functionalized gold nanoparticles (MGF-AuNPs) and its</p> ... Show More
View Publication
Crossref
Publication Date
Sun Feb 08 2009
Journal Name
Ibn Al- Haitham J. For Pure & Appl. Sci.
Evaluation of Dot. ELISA test for Diagnosis Visceral Leishmaniasis in Infected Children
...Show More Authors

Evaluation of Dot. ELISA test for Diagnosis Visceral Leishmaniasis in Infected Children

Publication Date
Thu Dec 01 2011
Journal Name
Swarm And Evolutionary Computation
Energy-aware evolutionary routing protocol for dynamic clustering of wireless sensor networks
...Show More Authors

Scopus (169)
Crossref (138)
Scopus Clarivate Crossref
Publication Date
Mon Jul 17 2023
Journal Name
Aip Conference Proceedings
Calculation of modes properties for multimode optical fibers at 633 nm wavelength
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jun 16 2021
Journal Name
Cognitive Computation
Deep Transfer Learning for Improved Detection of Keratoconus using Corneal Topographic Maps
...Show More Authors
Abstract <p>Clinical keratoconus (KCN) detection is a challenging and time-consuming task. In the diagnosis process, ophthalmologists must revise demographic and clinical ophthalmic examinations. The latter include slit-lamb, corneal topographic maps, and Pentacam indices (PI). We propose an Ensemble of Deep Transfer Learning (EDTL) based on corneal topographic maps. We consider four pretrained networks, SqueezeNet (SqN), AlexNet (AN), ShuffleNet (SfN), and MobileNet-v2 (MN), and fine-tune them on a dataset of KCN and normal cases, each including four topographic maps. We also consider a PI classifier. Then, our EDTL method combines the output probabilities of each of the five classifiers to obtain a decision b</p> ... Show More
View Publication
Scopus (34)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Iraqi Journal Of Veterinary Sciences
Genetic confirmation for morphological identification of Stilesia globipunctata in camel in Iraq
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Simulation of Batch Reactive Distillation for Biodiesel Production from Oleic Acid Esterification
...Show More Authors

The present work concerns with simulating unsteady state equilibrium model for production of methyl oleate (biodiesel) from reaction of oleic acid with methanol using sulfuric acid as a catalyst in batch reactive distillation. MESHR equations of equilibrium model were solved using MATLAB (R2010a). The validity of simulation model was tested by comparing the simulation results with a data available in literature. UNIQUAC liquid phase activity coefficient model is the most appropriate model to describe the non-ideality of OLAC-MEOH-MEOL-H2O system. The chemical reactions rates results from EQ model indicating the rates are controlled by chemical kinetics. Several variables was studied such as molar ratio of methanol to oleic acid 4:1, 6:1

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Investigation of nonlinear optical properties for laser dyes-doped polymer thin film
...Show More Authors

Solutions of dyes Rhodamine 6G (Rh6G) and Coumarin480(C480) were prepared at five concentrations (1x10-3, 5x10-4, 1x10-4, 5x10-5 and1x10-5) mol/l, the mixing was stirred to obtain on a homogenous solution, the(poly methyl-methacrylate) (PMMA) was solved by chloroform solvent with certain ratio, afterward (PMMA+Rh6G) and (PMMA+C480) thin films were prepared by casting method on glass block which has substrate with dimensions (7.5 x2.5)cm2, the prepared samples were left in dark place at room temperature for 24 hours to obtain uniform and homogenous thin films. UV-VIS absorption spectra, transmission spectra and fluorescence spectra were done to measure linear refractive index and linear absorption coefficient. The nonlinear optical proper

... Show More
View Publication Preview PDF