Background: Extracorporeal Shock wave lithotripsy (ESWL) is widely used in treating patients with ureteralstones because it is effective, safe, and noninvasive. Based on factors such as size and the location of stones,there is a significant variation in the overall stone-free rate (SFR).Aim of the study: To evaluate the effect of ureteral wall thickness (UWT), stone attenuation, the time fromfirst attack of pain till first session of ESWL and stone/ rib density on the outcome of SWL in the treatmentof upper ureteral stones (UUS).Patient and methods: A prospective study when 127 patients with radio-opaque UUS ranging from 7 to 20mm and treated by ESWL were included in this study. The effect of (stone/ 12th rib) density by KUB, ureteralwall thickness by NCCT and the time from first attack of pain till first ESWL session was studied.Results: The overall successful fragmentation was 75.5%, with the overall success rates in the low density(LD) and high density (HD) groups were 83.8% and 52.94%, respectively. The average number of SWLsessions needed in the two groups for success was 1.9 compared with 2.7 sessions (p<0.05). For stones <10 mm; those with ureteral wall thickness <3.25 mm have success rate about 90.3% VS 69.7% with uretericwall thickness > 3.25 mm which is highly significant. Early ESWL within the first 24 hours of acute attackof first pain has successful fragmentation of 85.45%. With significant effect on number of ESWL sessions.The stone free rate reaches 91.1% for stones <10 mm.Conclusions: The stone free rate is inversely affected by stone /12th rib density ; ureteral wall thickness andthe time from first attack of pain till first session of ESWL, were important predictors of successful ESWL.
In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra
In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located that The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.
Low grade crude palm oil (LGCPO) presents as an attractive option as feedstock for biodiesel production due to its low cost and non-competition with food resources. Typically, LGCPO contains high contents of free fatty acids (FFA), rendering it impossible in direct trans-esterification processes due to the saponification reaction. Esterification is the typical pre-treatment process to reduce the FFA content and to produce fatty acid methyl ester (FAME). The pre-treatment of LGCPO using two different acid catalysts, such as titanium oxysulphate sulphuric acid complex hydrate (TiOSH) and 5-sulfosalicylic acid dihydrate (5-SOCAH) was investigated for the first time in this study. The optimum conditions for the homogenous catalyst (5-SOCAH) wer
... Show MoreIn this paper, a new equivalent lumped parameter model is proposed for describing the vibration of beams under the moving load effect. Also, an analytical formula for calculating such vibration for low-speed loads is presented. Furthermore, a MATLAB/Simulink model is introduced to give a simple and accurate solution that can be used to design beams subjected to any moving loads, i.e., loads of any magnitude and speed. In general, the proposed Simulink model can be used much easier than the alternative FEM software, which is usually used in designing such beams. The obtained results from the analytical formula and the proposed Simulink model were compared with those obtained from Ansys R19.0, and very good agreement has been shown. I
... Show MoreThis paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.
One of the most important problems facing the world today is the energy problem. The solution was in finding renewable energy sources such as solar energy. The solar energy applications in Iraq is facing many problems . One of the most important problems is the accumulation of dust on the solar panels surface which causes decreasing its performance sharply. In the present work, a new technique was presented by using two-axis solar tracking system to reduce the accumulated dust on the solar panel surface and compared it with the fixed solar panels which installed at tilt angles 30° and 45°. The results indicated that the maximum losses of the output power due to accumulation of dust on the fixed solar panels is about 31.4% and 23.1% res
... Show MoreThe main aim of this paper is to study how the different estimators of the two unknown parameters (shape and scale parameter) of a generalized exponential distribution behave for different sample sizes and for different parameter values. In particular,
. Maximum Likelihood, Percentile and Ordinary Least Square estimators had been implemented for different sample sizes (small, medium, and large) and assumed several contrasts initial values for the two parameters. Two indicators of performance Mean Square Error and Mean Percentile Error were used and the comparisons were carried out between different methods of estimation by using monte carlo simulation technique .. It was obse
... Show MoreBackground: Fifteen percent of small for gestational age are small as a result of fetal growth restriction, which could be due to maternal, placental or fetal factors. It is an important clinical problem associated with increase perinatal mortality and morbidity. Leptin is a protein that produced by many tissues including the placenta (syncytiotropholoast). Dysregulation of leptin metabolism may be implicated in preeclampsia and IUGR pathogenesis.
Aim of the study: To study the trend of leptin level alteration in maternal serum and cord blood in pregnancies complicated by fetal growth restriction and its relation with fetal outcome.
Methods: An Analytic, cross- sectional study conducted in Al-Elwyia Maternity Teaching Hospital and
In this work, we studied the effect of power variation on inductively coupled plasma parameters using numerical simulation. Different values were used for input power (750 W-1500 W), gas temperature 300K, gas pressure (0.02torr), 5 tourns of the copper coil and the plasma was produced at radio frequency (RF) 13.56 MHZ on the coil above the quartz chamber. For the previous purpose, a computer simulation in two dimensions axisymmetric, based on finite element method, was implemented for argon plasma. Based on the results we were able to obtain plasma with a higher density, which was represented by obtaining the plasma parameters (electron density, electric potential, total power, number density of argon ions, el
... Show More