Preferred Language
Articles
/
DxYkkIoBVTCNdQwCKaCz
Gas Chr Gas Chromatographic Separ aphic Separation of Phenol Deriv ation of Phenol Derivatives by Schiff- y SchiffBase Liquid Crystalline Stationary Phases
...Show More Authors

The chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other columns of different liquid crystalline percentages (15% and 25%) were used. A chromatogram with unoverlapped peaks was only obtained in both cases at 20% column loading. The order of elution isomers under the applied chromatographic conditions is discussed. The separation of these isomers is also discussed on the basis of stereo chemical confirmations.

Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Investigate Retention Behavior of 2-deoxycytidine in Hydrophilic Interaction Liquid Chromatography
...Show More Authors

A hydrophilic interaction chromatography has been investigated to separate 2-deoxycytidine chosen for nucleoside. A small molecule with specific features for human serum samples was 2-deoxycytidine tested. 2-deoxycytidine has been applied to self-made stationary hydrophilic phases (ZIC1 and ZIC5). The deoxycytidine (dCD) retention was investigated with varying concentrations of sodium acetate buffer, acetonitrile%, and pH. The results confirmed the hydrophilicity of 2-deoxycytidine. The exchanger retention mechanism was studied taking into account 2-deoxycytidine used for describing the interaction of hydrophilic and cation. For both ZIC1 and ZIC5 exchangers, we described and discussed the influence of chromatographic conditions (co

... Show More
View Publication
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jan 01 2007
Journal Name
Atti Della “fondazione Giorgio Ronchi”
Photo-physical characterization of Rhodamine B in liquid and solid solutions
...Show More Authors

SUMMARY. – Absorption, flourescence, quantum yield and lifetime of rhodamine B in chloroform, methanol and dimethyl sulfoxide were measured. A comparison was done of these quantities with those for solid solutions, which are obtained by mixing constant volume proportions of dye at a concentration of 1×10–4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide. The results showed that the addition of polymer to liquid concentrated solutions (1×10–4M/l) of rhodamine B dye from expecting, which leads to development of active medium for laser dye at high concentration, increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative

... Show More
Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
The Spectroscopic Behaviour of Rhodamine 6G in Liquid and Solid Solutions
...Show More Authors

Absorption, fluorescence, quantum yield and lifetime of rhodamine 6G in chloroform, methanol and dimethyl sulfoxide were measured. From a comparison of these quantities, with those for solid solutions (solid solutions are obtained by mixing constant volume proportions of dye at a concentration of 1*10-4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide). The results showed that the addition of polymer to liquid concentrated solutions (1*10-4M/l )of rhodamine 6G dye from expecting [which leading to development active medium for laser dye at high concentration] increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative lifetim

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
History of a Two-Phase Bubble Condensing in an immiscible Liquid
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and Determination of Poly Aromatic Hydrocarbons in Vegetables Samples in Baghdad City Using HPLC Technique
...Show More Authors

The Reversed  Phase High Performance Liquid  Chromatography (RP-HPLC) has been used for the separation of  Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which  was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate  of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were   polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage  of the heavy water ,ind

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 20 2023
Journal Name
Liquid Crystals
Synthesis and study the mesomorphic behaviour of some new 1,3,4-thiadiazoline derivatives
...Show More Authors

Investigation of mesomorphic properties of new 1,3,4-thiadiazolines (which are synthesised via many steps in Scheme 1) was carried out in this study. These compounds are designed to have a heterocyclic unit, a carboxylate linkage group and a polar ether chain at the end of the molecule adjacent to the benzene ring, which enhance the dipolar interactions forces (varied from one to eight carbons) to investigate the association properties of their phases. The structure of the target compounds and the intermediates were confirmed by 1H NMR, 13C NMR, mass and FTIR spectral techniques. Polarised microscopic studies revealed that all the compounds in the series exhibited enantiotropic liquid crystalline properties. This was further confirmed using

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Studying the Impact Strength of Layered Denture Base Resin
...Show More Authors

This paper displays the effect of uncoated and coated chopped carbon fibers with alumina Al2O3 or Tri calcium phosphate (TCP) on the impact strength of acrylic poly methyl methacrylate (PMMA) denture base resin. To improve bonding between carbon fibers and coating materials powders, the surface of carbon fibers has been treated with Para amino benzoic acid (C9H10N2O3) and poly vinyl alcohol (PVA) was also used. The morphology of the coating layers has been examined by field emission scanning electron microscope (FE-SEM). From the results, PMMA reinforced with uncoated chopped carbon fiber has high impact strength value but still have bad aesthetic.  Samples prepared b

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Engineering, Technology & Applied Science Research
The Influence of Base Layer Thickness in Flexible Pavements
...Show More Authors

Flexible pavement design and analysis were carried out in the past with semi-experimental methods, using elastic characteristics of pavement layers. Due to the complex interferences between various layers and their time consumption, the traditional pavement analysis, and design methods were replaced with fast and powerful methods including the Finite Element Method (FEM) and the Discrete Element Method (DEM). FEM requires less computational power and is more appropriate for continuous environments. In this study, flexible pavement consisting of 5 layers (surface, binder, base, subbase, and subgrade) had been analyzed using FEM. The ABAQUS (6.14-2) software had been utilized to investigate the influence of the base layer depth on ver

... Show More
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Chemical Papers
A solvent collection technique using dispersive liquid–liquid microextraction coupled with spectrophotometry for the trace determination of folic acid in pure, dosage forms and flaxseed
...Show More Authors

A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl

... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref