Background: The estimation of ferritin and related variables by complete serum iron profile, for Iraqi hashimoto’s patients to see the effect of thyroid hormone insufficiency, which may lead to deficiency of ferritin iron stores, this may be quite useful during the diagnosis and treatment of hashimoto’s patients. Patients and Method: The study was performed at National Center of Teaching laboratories of Medical city institute in Baghdad. Fifty newly diagnosed patients with hashimoto’s and forty apparently healthy controls. Diagnosis based on thyroid profile analysis including:Thyroid Stimulating Hormone (TSH), Thyroxine (totalT4) and Triiodothyronine (total T3), estimation of antibodies against thyroperoxidase, iron profile including: serum ferritin, serum iron, total iron-binding capacity (TIBC), unsaturated iron-binding capacity (UIBC) and Transferrin saturation (TSAT) for both groups. Result: The hashimoto’s patients have elevated levels of anti-TPO, TSH, TIBC, UIBC and TSATas compared with controls. Anti-TPO, TSH, UIBC and TSAT were significantly higher than that of controls, while TIBC is not significant. In other hand, hashimoto’s patients have lowered levels of Total T3, Total T4, Ferritin and Iron as compared with controls. Total T4, Ferritin and Iron were significantly lower than that of control,while TotalT3 is not significant. Conclusion: Statistical application for the current study by employing Receiver Operation Characteristic curve (ROC curve) shows the validaty of anti-TPO in addition to serum iron and total T4 to be used as a biomarkers for detection of hashimoto’s thyroiditis.
Al2O3 and Al2O3–Al composite coatings were deposited on steel specimens using Oxy-acetylene gas thermal spray gun. Alumina was mixed with Aluminum in six groups of concentrations (0, 5, 10,12,15 and 20% ) Al2O3, Specimens were tested for corrosion using Potentiodynamic polarization technique. Further tests were conducted for the effect of temperature on polarization curve and the hardness tests for the coated specimens. At first, Modelling was carried out using MINITAB-19, least square method, as a 2nd degree nonlinear model, bad results were achieved because of the high nonlinearity. Better result w
Introduction: The use of screw-retained hybrid arch bars (HABs) is a relatively recent development in the treatment of mandibular fractures. The purpose of this study is to compare the clinical outcome between HAB and the conventional Erich arch bar (EAB) in the closed treatment of mandibular fractures. Materials and methods: This study included 18 patients who were treated for mandibular fractures with maxillomandibular fixation (MMF), patients were randomly assigned into a control group (n = 10) in which EAB was used and study group (n = 8) in which HAB was used. The outcome variables were time required for application and removal, gingival inflammation scores, postoperative complications, and incidence of wire-stick injury or gloves perf
... Show MoreWater has a great self-generating capacity that can neutralize the polluting interventions carried out by humans. However, if human activities continue this uncontrolled and unsustainable exploitation of this resource, this regenerating capacity shall fail and it will be jeopardized definitively. Shatt Al-Arab River in South of Iraq. It has an active role in providing water for irrigation, industry, domestic use and a commercial gateway to Iraq. in the last five years Shatt Al-Arab suffered from a rise in pollutants due to the severe decline in sewage networks, irregular networks and pesticide products, as well as the outputs of factories and companies that find their way to water sou
The osseodensification (OD) drilling technique was suggested as an alveolar ridge expansion technique, so the aim of this prospective clinical study was to evaluate the amount of bone expansion obtained by the OD drilling technique and its effect on implant stability in patients with narrow alveolar ridges. The width of the alveolar ridge was measured at the crest before and after implant site preparation, whereas the implant stability was measured using Osstell Beacon implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. Twenty-three patients were included; they received 40 implants. The mean (± standard deviation [SD]) amount of expansion was 1.29 (± 0.41) mm, and the difference b
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show More