Preferred Language
Articles
/
DhaB4YsBVTCNdQwCDeOl
METAL COMPLEXES OF SEMICARBAZONE LIGAND DERIVED FROM MANNICH-β-AMINOCARBONYL: SYNTHESIS, STRUCTURAL CHARACTERISATION, THERMAL PROPERTIES AND BIOLOGICAL ACTIVITY
...Show More Authors

The synthesis of a new tridentate Schiff-base ligand and its metal complexes are reported. The reaction of ((2R)-4-methyl-2-((S)-(phenylamino)(p-tolyl) methyl) cyclohexan-1-one) with semicarbazide in a 1: 1 mole ratio resulted in the formation of the title ligand ((E)-2-((2S)-4-methyl-2-((R)(phenylamino)(ptolyl) methyl) cyclohexylidene) hydrazine-1-carboxamide)((HL). The reaction of the ligand with Co (II) and Ni (II), Cu (II), Zn (II) and Cd (II) ions in a 1: 1 (L: M) mole ratio gave the title complexes. Physico-chemical techniques were implemented, as required, to characterise the ligand and complexes. These include; elemental microanalysis, 1H, 13C-NMR and mass spectra, FT-IR and electronic spectra, magnetic susceptibility and conductance. These analyses revealed the isolation of octahedral, square planar and tetrahedral geometry about Co (II) and Cu (II); Ni (II); and (Zn (II), Cd (II)) ions, respectively. Thermal stability (TGA-DSC) of the ligand and selected complexes were also investigated. The antimicrobial activity of the ligand and its complexes against several bacterial strains and fungi species were examined. The collected data indicated that the complexes are more active against several kinds of organisms, under survey, compared with the free ligand.

Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
D-Shaped Photonic Crystal Fiber Toxic Metal Ions (Arsenic) Sensor Based on Surface Plasmon Resonance
...Show More Authors

In this work, a Photonic Crystal Fiber (PCF) sensor based on the Surface Plasmon Resonance (SPR) technology was proposed. A thin layer of gold (Au) was deposited on a D-shaped Photonic Crystal Fiber (PCF), which was coated with plasmonic chemically stable gold material with a thickness of 40nm. The performance parameters like sensitivity including wavelength sensitivity and amplitude sensitivity and resolution were evaluated by simulation using COMSOL software. The proposed sensor was created by using the finite element approach, it is numerically examined. The results show that the surface of D-shaped Photonic Crystal Fiber coated with Au behaves as a sensor to detect the refractive index (IR) of toxic metal ions. The impacts of the str

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Applied Energy
Melting enhancement in triplex-tube latent heat energy storage system using nanoparticles-metal foam combination
...Show More Authors

View Publication
Scopus (287)
Crossref (281)
Scopus Clarivate Crossref
Publication Date
Sat Apr 04 2020
Journal Name
Biochemical And Cellular Archives
SYNTHESIS, CHARACTERIZATION AND EVALUATION OF ANTIOXIDANT IN-VIVO AND IN-VITRO AND ANTIBACTERIAL FOR N-(3,4- DIHYDROXYBENZYLIDENE) ACETOHYDRAZONE-2-(BENZYLTHIO) BENZIMIDAZOLE
...Show More Authors

Publication Date
Thu Oct 01 2015
Journal Name
Iraqi Journal Of Science
optimization of pectinase production from pesudomonas sp. isolated from iraqi soi
...Show More Authors

Publication Date
Mon Jan 01 2018
Journal Name
Eco Env And Cons
Histological changes resulting from the use of sublethal concentrations from insecticide.....
...Show More Authors

.

Publication Date
Wed Mar 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Design a radio receiver for solar activity observation in VLF band
...Show More Authors

Solar activity monitoring is important in our life because of its direct or indirect influence on our life, not only on ionospheric communications. To study solar activity, researchers need measuring and monitoring instruments, these instruments are mostly expensive and are not available in all universities. In this paper, a very low frequency radio receiver had been designed and implemented with components available in most markets to support the researchers, college students, and radio astronomy amateurs with a minimum input voltage less than 100µV, an output voltage less than 135 m V with no distortion and an overall gain of 34dB. A comparison had been done between two circuit structures using a workbench software program and experim

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Sep 30 2024
Journal Name
Iraqi Journal Of Science
Use of Scalp Hair as a Biomarker to Determine Airborne Heavy Metal Concentrations for the Academic Laboratory Employees
...Show More Authors

Academic chemical laboratories (ACL) are considered public places  the employees come in contact with a variety of pollutants. The aim of the current study was to detect heavy metals levels in the indoor air of ACL in two universities in Baghdad city and assess their levels in the academic employees’ scalp hair as biomarkers. Air samples inside ACL were collected to detect Fe, Cd, Zn, Pb and Cu. Scalp hair samples were collected from 40 adult chemical laboratory employees aged 30-60 years, who worked 5 days/week for 6 hours a day. Personal information relating to employees such as age, duration of exposure, smoking habit and sex, was collected as a questionnaire. The results of this study concluded that academic laboratory employ

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Fiber And Integrated Optics
Design Investigation of 2 × 2 Mach–Zehnder Optical Switch Based on a Metal–Polymer–Silicon Hybrid Plasmonic Waveguide
...Show More Authors

In this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Nanomedicine Research Journal
Preparation, Characterization, Antimicrobial and Antitumor Activity of Chitosan Schiff base / PVA / PVP Au, Ag Nanocomposite in Treatment of Breast Cancer Cell Line
...Show More Authors

Objective(s): Biocompatibility, non-toxicity, minimal allergenicity, and biodegradability are all characteristics of chitosan. Other biological properties of chitosan have been reported, including antitumor, antimicrobial and antioxidant activities. This research aim is the synthesis of drug compounds by preparation and characterization of polymer chitosan Schiff base and chitosan Schiff base / Poly vinyl alcohol / poly vinyl pyrrolidone Nanocomposite and study applications (anticancer cell line, antimicrobial agents). Methods: Chitosan Schiff base was prepared from the reaction of chitosan with carbonyl group of 4-nitro benzaldehyde. Polymer blend have been prepared by solution casting method. Chitosan Schiff base mixing with PVA and PVP

... Show More
Preview PDF
Scopus (6)
Scopus
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
A study of the effect of new cobalt (II) complex and cyclophosphamide drug on (GPT, ALP) activity by using in vivo system
...Show More Authors

The present work involved a study the effect of cobalt(II) complex with formula [CoL(H2O)NO3] .4ETOH where L=Nitro [5-(P-nitro phenyl) -4-phenyl-1,2,4 traizole-3-dithiocarbamato hydrazide] aqua. (4) Ethanol and anti-cancer drug - cyclophosphamide on specific activity of two liver enzymes (GPT,ALP) by utilizing an in vivo system in female mice. On the enzymatic level an inhibition in the activity of GPT was noticed in different body organs such as liver, kidney and lung. The inhibition was noticed in both test and cyclophosphamide drug (cp). Mice were treated with three doses of cyclophosphamide (90,180, 250) ?g/ mouse for three days. The same doses were used for the cobalt (II) complex. The liver shows the highest rate of(GPT) inhibition co

... Show More
View Publication Preview PDF
Crossref