Preferred Language
Articles
/
DhYPxokBVTCNdQwCVI1Z
Sensitive spectrophoto metric determination of doxycycline in pure and dosage forms using p-bromanil
...Show More Authors

A simple, precise, and sensitive spectrophotometric method has been established for the analysis of doxycycline. The method includes direct charge transfer complexation of doxycycline withp-Bromanil in acetonitrileto form a colored complex. The intensely colored product formed was quantified based on the absorption band at 377 nm under optimum condition. Beer’s law is obeyed in the concentration range of 1–50 μg.mL-1 with molar absorptivity of 1.5725x104 L.mol-1.cm-1, Sandell's sensitivity index (0.0283) μg.cm-2, detection limit of 0.1064 μg.mL-1, quantification limit 0.3224 μg.mL-1 and association constant of the formed complex (0.75x103). The developed method could find application in routine quality control of doxycycline and has been successfully applied for the determination of the cited drug in commercial formulations (capsules) with good accuracy and precision and without a detectable interference from common excipients.

Scopus
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
The impact of the use of pulverized black bean and fat in homemade bread mix in the quality and attributes Alkhoznip
...Show More Authors

Factory is trotting home favorite of of Aeidid of Iraqi families since he Amta imparted to the taste of the housewife on the method of processing and preparation and the possibility of using some of the ingredients to raise the nutritional value of meat, sesame and other, but how keep Bz'zajh this product Atne storage

View Publication Preview PDF
Publication Date
Sun Jun 09 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Status of CHADS2 and CHA2DS2-VASc Scores in Predicting Risk of Stroke and its Prevention in Iraqi Patients with Atrial Fibrillation
...Show More Authors

Atrial fibrillation is associates with elevated risk of stroke. The simplest stroke risk assessment schemes are CHADS2 and CHA2DS2-VASc score. Aspirin and oral anticoagulants are recommended for stroke prevention in such patients.

The aim of this study was to  assess status of CHADS2 and CHA2DS2-VASc scores in Iraqi atrial fibrillation patients and to report current status of stroke prevention in these patients with either warfarin or aspirin in relation to these scores.

This prospective cross-sectional study was carried out at Tikrit, Samarra, Sharqat, Baquba, and AL-Numaan hospitals from July 2017 to October 2017. CHADS2

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Measurement the Concentrations of Radon and Thoron and Their Progeny in the Air Samples of Al-Haswaa City in Babylon province
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2018
Journal Name
Practice Periodical On Structural Design And Construction
Hazards and Risk in Construction and the Impact of Incentives and Rewards on Safety Outcomes
...Show More Authors

View Publication
Scopus (31)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Compressive Strength Performance of Reactive Powder Concrete Using Different Types of Materials as a Partial Replacement of Fine Aggregate
...Show More Authors

Reactive Powder Concrete (RPC) can be incorporate as a one of the most important and progressive concrete technology. It is a special type of ultra-high strength concrete (UHSC) that’s exclude the coarse aggregate from its constitutive materials. In this research an experimental study had been carried out to investigate the effect of using three types of materials (porcelain aggregate) and others sustainable materials (glass waste and granular activated carbon) as a partial replacement of fine aggregate. Four percentages had considered (0, 10, 15 and 20) % to achieve better understanding for the influence of these materials upon the compressive strength of RPC. Four curing ages had included in this study, these are; 7, 28, 60 and

... Show More
View Publication
Crossref (7)
Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Key Engineering Materials
Compressive Strength Performance of Reactive Powder Concrete Using Different Types of Materials as a Partial Replacement of Fine Aggregate
...Show More Authors

Reactive Powder Concrete (RPC) can be incorporate as a one of the most important and progressive concrete technology. It is a special type of ultra-high strength concrete (UHSC) that’s exclude the coarse aggregate from its constitutive materials. In this research an experimental study had been carried out to investigate the effect of using three types of materials (porcelain aggregate) and others sustainable materials (glass waste and granular activated carbon) as a partial replacement of fine aggregate. Four percentages had considered (0, 10, 15 and 20) % to achieve better understanding for the influence of these materials upon the compressive strength of RPC. Four curing ages had included in this study, these are; 7, 28, 60 and

... Show More
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Sat Jun 25 2022
Journal Name
International Journal Of Drug Delivery Technology
Expression of Urotensin II of Human Placental Tissues and in Serum in Gestational Diabetic Mellitus in Iraqi Woman
...Show More Authors

The placenta is an organ between the mother and fetus necessary for fetal growth and development. Gestational diabetes mellitus (DM) is the most frequent metabolic condition detected during pregnancy. It is characterized as hyperglycemia of various severity with onset or first detection during pregnancy that does not clearly describe any form of preexisting diabetes. Urotensin II (UII), a pluripotent vasoactive peptide, is important in developing insulin resistance. This study aimed to determine the level of Urotensin II(UII) in placenta and in the serum of diabetic and nondiabetic women. Methods The blood and placenta tissue collected from 50 ladies had been enrolled in this research ( 25 females with uncomplicated), (25 women with gestati

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Hydrology
Boosted artificial intelligence model using improved alpha-guided grey wolf optimizer for groundwater level prediction: Comparative study and insight for federated learning technology
...Show More Authors

View Publication
Scopus (45)
Crossref (49)
Scopus Clarivate Crossref
Publication Date
Thu Mar 12 2020
Journal Name
Al-khwarizmi Engineering Journal
Improving Reverse Engineering Processes by using Articulated Arm Coordinate Measuring Machine
...Show More Authors

The invention relates to a coordinate measuring machine (CMM) for determining a measuring position of a probe. The AACMM isdepends on the robotkinematics (forward and reverse) in their measurementprinciple, i.e., using the AACMM links and joint angles todetermine the exact workspace or part coordinates. Hence, themeasurements are obtained using an AACMM will be extremely accurate and precise since that ismerely dependent on rigid structural parameters and the only source of measurement error is due to human operators. In this paper, a new AACMM design was proposed. The new AACMM design addresses common issues such as solving the complex kinematics, overcoming the workspace limitation, avoiding singularity, and eliminating the effects of

... Show More
View Publication Preview PDF