Use of the pulsed infrared diode laser (904 nm) in the treatment of alopecia areata
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Arthroscopic micro fracture and intra articular whole bone marrow injection for the treatment of articular cartilage lesions in the knee joint. Authors
...Show More Authors

Abstract Background: Articular cartilage lesions in the knee joint are frequently seen,its treatment represents a challenge for orthopedic surgeons especially in young age patients and if left untreated,then they can progress to advanced osteoarthritis that may affect the functional status of the patients.Many treatment modalities had developed for these lesions, in the current study arthroscopic micro fracture plus intra articular whole bone marrow(WBM) injection was used as modality of treating these lesions. Objectives: to assess the effectiveness of arthroscopic micro fracture plus WBM intra articular injection as a treatment modality for knee articular cartilage lesions. Patients and Methods : a prospective experimental study was perf

... Show More
Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
New Technique for Treatment of the dust accumulation from PV solar panels surface
...Show More Authors

One of the most important problems facing the world today is the energy problem. The solution was in finding renewable energy sources such as solar energy. The solar energy applications in Iraq is facing many problems . One of the most important problems is the accumulation of dust on the solar panels surface which causes decreasing its performance sharply. In the present work, a new technique was presented by using two-axis solar tracking system to reduce the accumulated dust on the solar panel surface and compared it with the fixed solar panels which installed at tilt angles 30° and 45°. The results indicated that the maximum losses of the output power due to accumulation of dust on the fixed solar panels is about 31.4% and 23.1% res

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Two-Phase Partitioning Bioreactor for the Treatment of Crude Oil- Contaminated Aqueous Solution
...Show More Authors

A new application of a combined solvent extraction and two-phase biodegradation processes using two-liquid phase partitioning bioreactor (TLPPB) technique was proposed and developed to enhance the cleanup of high concentration of crude oil from aqueous phase using acclimated mixed culture in an anaerobic environment. Silicone oil was used as the organic extractive phase for being a water-immiscible, biocompatible and non-biodegradable. Acclimation, cell growth of mixed cultures, and biodegradation of crude oil in aqueous samples were experimentally studied at 30±2ºC. Anaerobic biodegradation of crude oil was examined at four different initial concentrations of crude oil including 500, 1000, 2000, and 5000 mg/L. Complete removal of crud

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 13 2020
Journal Name
Clinical And Experimental Dental Research
The efficacy of polyether‐ether‐ketone wire as a retainer following orthodontic treatment
...Show More Authors
Abstract<sec><title>Objectives

To investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.

Materials and methods

Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflec

... Show More
View Publication
Scopus (20)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
2nd International Conference On Materials Engineering &amp; Science (iconmeas 2019)
Modeling of adsorption isotherms of oil content through the electrocoagulation treatment of real oily wastewater
...Show More Authors

View Publication Preview PDF
Scopus (29)
Crossref (24)
Scopus Crossref
Publication Date
Sun Jan 01 2017
Ultra low power and highly linearized LNA for V-band RF applications in 180 nm CMOS technology
...Show More Authors

Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Nov 09 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of the use of automated accounting systems technology in enhancing the efficiency and effectiveness of the internal control system.: دراسة تحليلية لعينة من الموظفين العاملين في اقسام المحاسبة والتدقيق في الجامعات البحرينية
...Show More Authors

The research aims to show the relationship between the use of automated accounting systems technology and its impact on enhancing the efficiency and effectiveness of the internal control system in a sample of Bahraini universities in light of the rapid changes in the                                       electronic business environment. Automated accounting and its impact on enhancing the efficiency and effectiveness of the internal control system, and it is concluded through the analytical study of the research sample that there is a percenta

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 11 2021
Journal Name
Nano Express
Near-infrared PbS quantum dots functionalized with affibodies and ZnPP for targeted imaging and therapeutic applications
...Show More Authors
Abstract<p>We report a new theranostic device based on lead sulfide quantum dots (PbS QDs) with optical emission in the near infrared wavelength range decorated with affibodies (small 6.5 kDa protein-based antibody replacements) specific to the cancer biomarker human epidermal growth factor receptor 2 (HER2), and zinc(II) protoporphyrin IX (ZnPP) to combine imaging, targeting and therapy within one nanostructure. Colloidal PbS QDs were synthesized in aqueous solution with a nanocrystal diameter of ∼5 nm and photoluminescence emission in the near infrared wavelength range. The Z<sub>HER2:432</sub> affibody, mutated through the introduction of two cysteine residues at the C-terminus (</p> ... Show More
View Publication Preview PDF
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu May 31 2018
On the Use of 6th-Order Tunable Complementary Metal-Oxide-Semiconductor Varactor based Filter in Ultra-Wideband Low Noise Amplifier
...Show More Authors
Background:

The plethora of the emerged radio frequency applications makes the frequency spectrum crowded by many applications and hence the ability to detect specific application’s frequency without distortion is a difficult task to achieve.

Objective:

The goal is to achieve a method to mitigate the highest interferer power in the frequency spectrum in order to eliminate the distortion.

Method:

This paper presents the application of the proposed tunable 6th-order notch filter on Ultra-Wideband (UWB) Complementary Metal-Oxide-Semiconductor (CMOS) Low Noise

... Show More
Scopus Crossref
Publication Date
Wed Mar 09 2022
Journal Name
Journal Of Craniofacial Surgery
The Use of Osseodensification for Ridge Expansion and Dental Implant Placement in Narrow Alveolar Ridges: A Prospective Observational Clinical Study
...Show More Authors

The osseodensification (OD) drilling technique was suggested as an alveolar ridge expansion technique, so the aim of this prospective clinical study was to evaluate the amount of bone expansion obtained by the OD drilling technique and its effect on implant stability in patients with narrow alveolar ridges. The width of the alveolar ridge was measured at the crest before and after implant site preparation, whereas the implant stability was measured using Osstell Beacon implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. Twenty-three patients were included; they received 40 implants. The mean (± standard deviation [SD]) amount of expansion was 1.29 (± 0.41) mm, and the difference b

... Show More
View Publication
Scopus (8)
Crossref (12)
Scopus Clarivate Crossref