Dynamic machine foundations can be considered as a necessary component of the industrial infrastructure. Design of the dynamic equipment foundations has, however, traditionally been grounded on a rule of thumb that is inaccurate and rigid to use at the discretion of the engineers. The conventional rule of thumb, which includes minimum weight ratios and resonance avoidance criteria, has been used singularly with two poles, which can be either conservatively designed systems that are too heavy, or systems that are going to experience too much vibration and fatigue. This paper presents a novel, analytical framework for the reinterpretation of traditional design practices, using a physics-based approach, and results in a single, unified overall performance metric: the Combined Safety Index (CSI). The method utilizes frequency-dependent soil-foundation interaction models, allowing for a systematic evaluation of both inertially related and resonantly related stability under harmonic excitations. Using large-scale validations of real-world, global operational and geotechnical data from numerous case studies, including centrifugal compressors, blowers, and horizontal equipment, the reliability of the framework was demonstrated to be high (> 97%), with greater than 97% of the simulated designs meeting CSI ≥ 1.0. In addition, the method allows for mass optimization resulting in reductions in the amount of concrete used, and thus reductions in cost and environmental impact, of up to 45%. Unlike rule-of-thumb methods, this model allows designers to make informed decisions regarding the trade-off between the amount of mass of the foundation and detuning of the operating frequency, and thus supports economic efficiency and environmental sustainability. Statistical analyses, including local and global sensitivity analysis and Monte Carlo uncertainty quantification of the results, confirmed that the primary variables controlling system safety are the damping ratio (ζ) and the mass of the foundation (Wf). This work therefore provides practicing engineers with a practical, computationally efficient tool for designing safer, more sustainable foundations, and assists in advancing the state-of-the-art in design practice and in advancing digital engineering. © Springer Nature Switzerland AG 2026.
Background: Since its introduction to musculoskeletal imaging in the early 1980, magnetic resonance imaging (MRI) has revolutionized diagnostic imaging of the knee. It is therefore become the examination of choice in the evaluation of internal joint structures of the knee like menisci, cruciate ligaments, and articular cartilage.Objectives: to describe the MRI finding in various knee injuries.Patients and methods: A cross sectional study was done on 130 patients with history of knee injury in MRI unit at institute of radiology and al-Shaheed Ghazi Al-Hariri Hospital in medical city complex - Baghdad, from October 2011 to February 2013 includes 103 men, 27 women; the mean age was 33.86 years. MR imaging studies of the knee performed using
... Show MoreIn the pandemic era of COVID19, software engineering and artificial intelligence tools played a major role in monitoring, managing, and predicting the spread of the virus. According to reports released by the World Health Organization, all attempts to prevent any form of infection are highly recommended among people. One side of avoiding infection is requiring people to wear face masks. The problem is that some people do not incline to wear a face mask, and guiding them manually by police is not easy especially in a large or public area to avoid this infection. The purpose of this paper is to construct a software tool called Face Mask Detection (FMD) to detect any face that does not wear a mask in a specific
... Show MoreSurface Plasmon Resonance (SPR)-based plastic optical fiber sensor for estimating the concentration and refractive index of sugar in human blood serum. The sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal. The blood serum is placed on gold coated core of an Optical grade plastic optical fiber of 980 µm core diameter.
Electrical resistivity tomography (ERT) methods have been increasingly used in various shallow depth archaeological prospections in the last few decades. These non‐invasive techniques can save time, costs, and efforts in archaeological prospection and yield detailed images of subsurface anomalies. We present the results of quasi‐three‐dimensional (3D) ERT measurements in an area of a presumed Roman construction, using a dense electrode network of parallel and orthogonal profiles in dipole–dipole configuration. A roll‐along technique has been utilized to cover a large part of the archaeological site with a 25 cm electrode and profile spacing, respectively. We have designed a new field proce
The gas-lift method is crucial for maintaining oil production, particularly from an established field when the natural energy of the reservoirs is depleted. To maximize oil production, a major field's gas injection rate must be distributed as efficiently as possible across its gas-lift network system. Common gas-lift optimization techniques may lose their effectiveness and become unable to replicate the gas-lift optimum in a large network system due to problems with multi-objective, multi-constrained & restricted gas injection rate distribution. The main objective of the research is to determine the possibility of using the genetic algorithm (GA) technique to achieve the optimum distribution for the continuous gas-lift injectio
... Show MoreIn this work the effect of choosing tri-circular tube section had been addressed to minimize the end effector’s error, a comparison had been made between the tri-tube section and the traditional square cross section for a robot arm, the study shows that for the same weight of square section and tri-tube section the error may be reduced by about 33%.
A program had been built up by the use of MathCAD software to calculate the minimum weight of a square section robot arm that could with stand a given pay load and gives a minimum deflection. The second part of the program makes an optimization process for the dimension of the cross section and gives the dimensions of the tri-circular tube cross section that have the same weight of
... Show MoreFree-electron lasers (FELs) are disruptive light sources that offer ultrashort pulses, wide spectral tunability, and superior coherence, making them promising candidates for next-generation photonic technologies. However, conventional FEL facilities are large-scale and complex, limiting their integration into communication systems. This study investigates the potential of compact FELs as scalable and versatile light sources for beyond-6G and quantum communication infrastructures. A theoretical framework was established to model resonance conditions, gain dynamics, coherence properties, pulse-duration-limited bit rates, and signal-to-noise ratio (SNR). These models were implemented in MATLAB simulations using parameters representativ
... Show More