The present study involves experimental analysis of the modified Closed Wet Cooling Tower (CWCT) based on first and second law of thermodynamics, to gain a deeper knowledge in this important field of engineering in Iraq. For this purpose, a prototype of CWCT optimized by added packing under a heat exchanger was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the towers thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of air measured at intermediate points of the heat exchanger and packing. Exergy of water and air were calculated by applying the exergy
... Show MoreBackground: Osteoporosis is a skeletal defect manifested by a reduction of bone strength as a result of reduced bone mass to the extent that there is a higher risk of fracture even on minor trauma. Hysterectomy in a premenopausal woman is a well known cause of ovarian failure resulting in an increased risk of osteoporosis.
Objective : To clarify bisphosphonate's preventive effect on osteopenia and osteoporosis in premenopausal women after hysterectomy.
Type of the study: Cross –sectional study.
Method: 84 premenopausal females post hysterectomy aged between 40 – 50 years, were enrolled in this randomized controlled double blinded trail a
... Show MoreThe objectives of the study were to identify the incidence rate and characteristics of adverse drug events (ADEs) in nursing homes (NHs) using the ADE trigger tool and to evaluate the relationships between resident and facility work system factors and incidence of ADEs using the System Engineering Initiative for Patient Safety (SEIPS) model. The study used 2 observational quantitative methods, retrospective resident chart extraction, and surveys. The participating staff included Directors of nursing, registered nurses, certified nurse assistants (CNAs). Data were collected from fall 2016 to spring 2017 from 11 NHs in 9 cities in Iowa. Binary logistic regression with generalized estimated equations was used to measure the association
... Show MoreObjectives: To assess the qualifications and performance of newly graduated pharmacists and explore factors that affect their performance in public hospitals. Methods: This qualitative study included face-to-face, semi-structured interviews with hospital practitioner pharmacists. It was conducted between March and May 2023 in Kerbala province, Iraq. The participating pharmacists were selected purposefully because they had three or more years of work experience at governmental hospitals. The audio-recording interviews were transcribed. Thematic analyses were used to generate themes and subthemes from the interviews. Results: Twenty-seven hospital pharmacists participated in this study. The study found that there are several factors t
... Show MoreA seemingly uncorrelated regression (SUR) model is a special case of multivariate models, in which the error terms in these equations are contemporaneously related. The method estimator (GLS) is efficient because it takes into account the covariance structure of errors, but it is also very sensitive to outliers. The robust SUR estimator can dealing outliers. We propose two robust methods for calculating the estimator, which are (S-Estimations, and FastSUR). We find that it significantly improved the quality of SUR model estimates. In addition, the results gave the FastSUR method superiority over the S method in dealing with outliers contained in the data set, as it has lower (MSE and RMSE) and higher (R-Squared and R-Square Adjus
... Show MoreThis paper proposes a new method to tune a fractional order PID controller. This method utilizes both the analytic and numeric approach to determine the controller parameters. The control design specifications that must be achieved by the control system are gain crossover frequency, phase margin, and peak magnitude at the resonant frequency, where the latter is a new design specification suggested by this paper. These specifications results in three equations in five unknown variables. Assuming that certain relations exist between two variables and discretizing one of them, a performance index can be evaluated and the optimal controller parameters that minimize this performance index are selected. As a case study, a thir
... Show MoreThis paper proposes a new method to tune a fractional order PID controller. This method utilizes both the analytic and numeric approach to determine the controller parameters. The control design specifications that must be achieved by the control system are gain crossover frequency, phase margin, and peak magnitude at the resonant frequency, where the latter is a new design specification suggested by this paper. These specifications results in three equations in five unknown variables. Assuming that certain relations exist between two variables and discretizing one of them, a performance index can be evaluated and the optimal controller parameters that minimize this performance index are selected. As a case study, a third order linear time
... Show More