Abstract: Many treatment modalities have been introduced for correction of deficient alveolar ridge width. Bone expansion through the ridge split procedure is one of them. This technique was initiated in order to overcome many problems that usually associated with grafting procedures. The present study evaluated the effectiveness of piezoelectric device in performing ridge split using single-stage approach and assessed the outcomes during a period of about 4 months after surgery. A total of 23 patients aged in range between 18 and 60 years underwent ridge split procedure with immediate insertion of dental implants. A panoramic radiograph was obtained before surgery. The gained bone was measured and surgical complications were recorded. Implants stability was measured using Osstell device. Postoperative clinical complications were assessed. After a healing period of 16 weeks, all the implants were uncovered and evaluated regarding clinical, radiographic, and resonance frequency analysis findings. The totally implemented ridge split procedures were 26 cases including 57 implants inserted immediately at the time of surgery. The initial ridge width varied between 1 and 3.5 mm while the final width ranged from 5.5 to 8 mm. The minimum bone gain was 2.5 mm and the maximum value reached up to 7 mm. Few and insignificant clinical compli- cations were recorded during the whole study. The survival rate was 100%. The study results indicated that piezoelectric ridge splitting technique is an effective, safe, and minimally invasive procedure. This technique has showed to be very successful in reducing the overall treatment period.
In this paper, a microcontroller-based electronic circuit have been designed and implemented for dental curing system using 8-bit MCS-51 microcontroller. Also a new control card is designed while considering advantages of microcontroller systems the time of curing was controlled automatically by preset values which were input from a push-button switch. An ignition based on PWM technique was used to reduce the high starting current needed for the halogen lamp. This paper and through the test result will show a good performance of the proposed system.
Background: The preparation of Platelet-rich plasma (PRP) is minimally invasive way, simple, low cost to obtain natural autologous growth factors and is now being widely used in different fields of medicine for its ability to increase the regeneration potential of tissue. The aim of this study was to investigate the effect of local application of autologous PRP gel on acceleration rate of osseointegration period by clinical assessment accomplished by determining the changes in implant stability during 3 months healing period using resonance frequency analysis (RFA). Materials and methods: A total of 28 dental implants were inserted in edentulous maxillae or mandibles of 13 patients using a split mouth design, i.e. each patient was received
... Show MoreZinc Oxide is an indispensable substance in the field of dental treatment. It is used daily and intensively in all governmental and private dental clinics, leading to the disposal of very high concentrations of zinc with waste and eventually in landfill sites as a final destination for solid waste removal. This indicates the urgent need to investigate its behavior upon disposal due to the surrounding conditions. Approximately 4195 g of mixed dental waste samples were collected from (17) healthcare centers in Baghdad Al-Karkh. The leaching behavior of ZnO powder was investigated through batch reactors using makeup dental solid waste samples. The ZnO leaching was tested with 3 conditions; acidic, alkaline, and Ionic Streng
... Show MoreProblem Statement: Despite the critical role of arm movement in freestyle swimming, many learners— specially female students at Baghdad University's College of Physical Education and Sport Sciences— face difficulties executing the pushing phase of the stroke correctly. This phase essential for generating propulsion and maintaining body coordination in water. Traditional teaching methods lack immediate feedback on the quality and force of arm movements, impeding effective motor learning and coordination. Approach: the researchers developed a custom-made device designed to measure the pressure force exerted by the palms during freestyle swimming. The device features pressure sensors attached both hands, a processor that analyzes the colle
... Show MorePure grade II titanium disks were coated with a thin coating of polyetherketoneketone (PEKK) polymer by RF magnetron sputtering using either nitrogen or argon gas. Sputtering technique was employed at 50 W for one hour at 60°C with continuous flow of nitrogen or argon gas. Field-emission scanning electron microscopy (FE-SEM) showed a continuous, homogeneous, rough PEKK surface coating without cracks. In addition, cross-sectional FE-SEM revealed an average coat thickness of 1.86 μm with argon gas and 1.96 μm with nitrogen gas. There was homogenous adhesion between the coating layer and substrate. The elemental analysis of titanium substrate revealed the presence of carbon, titanium, and oxygen. The RF magnetron sputtering with argon or ni
... Show MoreIdentify the effect of an educational design according to the repulsive (allosteric) learning model on the achievement of chemistry and lateral thinking. The sample consisted of (59) students from third-grade intermediate students. They were randomly distributed into two groups (experimental and control), and the equivalence was done in (chronological age, previous achievement in chemistry, intelligence, lateral thinking). The (30) students from experimental group were taught according to the instructional design, other 29 students from the (control) group were taught according to the usual method. Two tests done, one of them is an achievement test consisted of (30) items of the type of multiple choice, the other was a lateral think
... Show MoreBuffering of Local anaesthesia (LA) has been suggested as a mechanism to improve injection comfort and hasten the onset of anaesthesia. Aim This study aimed to evaluate the effectiveness of buffered LA in the extraction of maxillary premolars and molars. Materials and Methods This randomized controlled study included 100 patients who were indicated for extraction of maxillary posterior teeth, they were randomly divided into two groups; a study group that received infiltration of buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA, and a control group that received non-buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA. The buffering was performed using the Onset® LA buffering system (Onpharma®). The outcome va
... Show More