Abstract: Many treatment modalities have been introduced for correction of deficient alveolar ridge width. Bone expansion through the ridge split procedure is one of them. This technique was initiated in order to overcome many problems that usually associated with grafting procedures. The present study evaluated the effectiveness of piezoelectric device in performing ridge split using single-stage approach and assessed the outcomes during a period of about 4 months after surgery. A total of 23 patients aged in range between 18 and 60 years underwent ridge split procedure with immediate insertion of dental implants. A panoramic radiograph was obtained before surgery. The gained bone was measured and surgical complications were recorded. Implants stability was measured using Osstell device. Postoperative clinical complications were assessed. After a healing period of 16 weeks, all the implants were uncovered and evaluated regarding clinical, radiographic, and resonance frequency analysis findings. The totally implemented ridge split procedures were 26 cases including 57 implants inserted immediately at the time of surgery. The initial ridge width varied between 1 and 3.5 mm while the final width ranged from 5.5 to 8 mm. The minimum bone gain was 2.5 mm and the maximum value reached up to 7 mm. Few and insignificant clinical compli- cations were recorded during the whole study. The survival rate was 100%. The study results indicated that piezoelectric ridge splitting technique is an effective, safe, and minimally invasive procedure. This technique has showed to be very successful in reducing the overall treatment period.
Polyaniline (PANI) has been prepared by the oxidation method in order to fabricate it with various concentrations of copper nanoparticles (CuNPs) which produced using the reduction method. Various techniques have characterized pure PANI and PANI doped CuNPs composites, such as fourier transform infrared spectroscopy (FT-IR), X-ray diffraction spectroscopy (XRD), field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray spectroscopy (EDS), which were provided important information about the structure and morphology of the fabricated polymer nanocomposites. The properties of dielectric permittivity (έ), dielectric loss (ἔ) and electrical conductivity (σ_AC) properties were studied at room temperature versus a range
... Show MoreIn folk medicine there are various medicinal amalgamation possessing hepatoprotective activity. This activity is of significance because several toxins cause liver injury. Hence, many pharmaceutical companies are targeting herbal medicines for the treatment of liver abnormalities and towards evolving a safe and effective formulation with desired route of administration. In current review we have focused on the studies showing hepatoprotective effect using marine compounds and plant derived compounds. Liver disorder, a global health problem, usually include acute or chronic hepatitis, heptoses, and cirrhosis. It may be due to toxic chemicals and certain antibiotics. Uncontrolled consumption of alcohol also affects liver in an unhealthy wa
... Show MoreTest results of six half-scale reinforced concrete flat plates connections with an opening in the vicinity of the column are reported. The test specimens represent a portion of a slab bounded by the lines of contraflexure around the column. The tests were designed to study the effect of openings on the punching shear behavior of the slab-column connections. The test parameters were the location and the size of the openings. One specimen had no opening and the remaining five had various arrangements of openings around the column. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The openings in the specimens were square, with the sides parallel to the sides of the column. Three sizes of ope
... Show MorePolymer blended electrolytes of various concentrations of undoped PAN/PMMA (80/20, 75/25, 70/30, 65/35 and 60/40 wt%) and doped with lithium salts (LiCl, Li2SO4H2O, LiNO3, Li2CO3) at 20% wt have been prepared by the solution casting method using dimethylformamide as a solvent. The electrical conductivity has been carried out using an LCR meter. The results showed that the highest ionic conductivity was 2.80x10-7 (Ω.cm)-1 and 1.05x10-1 (Ω.cm)-1 at 100 kHz frequency at room temperature for undoped (60% PAN + 40% PMMA) and (80% PAN + 20% PMMA) doped with 20%wt Li2CO3 composite blends, respectively. It was found from the measurements of the A.C conductivity of undoped (PAN+PMMA) and doped with different lithium salts in the frequency
... Show More
A descriptive study, which was using an assessment approach, was conducted for the
determination of the impact of rheumatoid arthritis and osteoarthritis patient’s functional disability
upon their life style. The study was carried out at the Rheumatology and outpatients clinics of ALKarama
Teaching Hospital, Baghdad Teaching Hospital AL-Kindey Teaching Hospital and Specialized
surgeries Teaching Hospital for the period of October 15th 2003 through May 13th 2004 in Baghdad
City. A purposive (non-probability) sample of (245) arthritis patients which was comprised (111)
rheumatoid arthritis patients and (134) osteoarthritis patients, was selected out of the early stated
settings. The questionnaire was comprised of
Statement of the Problem. The use of orthodontic fixed appliances may adversely affect oral health leading to demineralizing lesions and the development of gingival problems. Aims of the Study. The study aimed to coat orthodontic archwires with chlorhexidine hexametaphosphate nanoparticles (CHX-HMP NPs) and to evaluate the elusion of CHX from CHX-HMP NPs. Materials and Methods. A solution of CHX-HMP nanoparticles with an overall concentration of 5 mM for both CHX and HMP was prepared, characterized (using atomic force microscope and Fourier transformation infrared spectroscopy), and used to coat orthodontic stainless steel (SSW) and NiTi archwires (NiTiW). The coated segments were characterized (using scanning electron microscopy
... Show MoreOily carwash wastewater is a high organic and chemical wastewater. This paper targeted to investigate a treatment to decrease the water consumption and contaminants in car-washing stations. Electrocoagulation combined with ultrasonic energy (Sono-Electrocoagulation) was suggested so that the carwash wastewater is treated to be reused. The effect of both the voltage and time of treatment on the removal of COD, turbidity, conductivity, and total dissolved solids (TDS) were studied at constant initial pH 7 and electrode distance 2 cm. The results showed the best results of removal COD, turbidity, TDS, and reduce electrical conductivity is when the voltage was 30 V and a treatment time of 90 minutes.
<
... Show More