Preferred Language
Articles
/
Cxb5kYcBVTCNdQwCYVZV
Synthesis, Characterization and Spectroscopic Study of New Metal Complexes form Heterocyclic Compounds for Photostability Study
...Show More Authors

In present project, new Schiff base of 4, 4'- (((1E, 1'E)-1,4-.phenylenebis- (methane-ylylidene))-bis-(azane-ylylidene)) bis-(5-(4-chlorophenyl) -4H -1,2,4-triazole-3-thione) (L3) has been synthesized by condensation of 4-amino-5-(4-chlorophenyl)-2,4-dihydro-3H-1,2,4-triazole-3-thione with benzene-1,4-dicarboxaldehyde. The new asymmetrical Schiff base (L3) used as a ligand to synthesize a new complex with Co(II), Ni(II), Cu(II), Pd(II), and Pt(IV) metal ions by 1:2 (Metal: ligand) ratio. New ligand and their complexes have been exanimated and Confirmed by Fourier-transform infrared (FT-IR), Ultraviolet-visible (UV-visible), Proton nuclear magnetic resonance (1HNMR), carbon13 nuclear magnetic resonance (13CNMR), carbon-hydrogen nitrogen sulfur (C-H-N-S), thermal analysis (TG), atomic-absorption-flame (AAF), cond-uctivity and Magnetic susceptibility. Examining new compounds through a calculation of photodegradation polystyrene films, assessed photo-stability activities. Results indicate Pt2L3 > Pd2L3 > Cu2L3 > Ni2L3 > Co2L3 > L3 > PS. Polymer stability is given for this the analysis of the reduction of weight, molecular average, reveals a more stable polystyrene PS.

Scopus
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Vibration Measurement and Analysis of knee-Ankle-Foot Orthosis (KAFO) Metal-Metal type
...Show More Authors

This paper deals with calculate stresses in Knee-Ankle-Foot-Orthosis as a result of the effect vibration during gait cycle for patient wearing KAFO .Experimental part included measurement interface pressure between KAFO and leg due to action muscles and body weigh on Orthosis. also measurement acceleration result from motion of defected leg by accelerometer .Results of Experimental part used input in theoretical part so as to calculate stresses result from applying pressure and acceleration on KAFO by engineering analysis program ANSYS 14.Resultes show stresses values in upper KAFO greater than lower KAFO that is back to muscles more effective in thigh part lead to recoding pressure higher than pressure in shank part.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 01 2026
Journal Name
Journal Of Nanostructures
Synthesis of New Polymeric Composite Materials Derived from 2,2-(1,6-Dioxohexane-1,6-diyl) Dihydrazinecarbothioamide
...Show More Authors

In this study, a new class of polymeric nanocomposites was synthesized and characterized.  One mole of dimethyl adipate and two moles of thiosemicarbazide in ethanol first reacted to form the compound [C1]. Compound [C1] then reacted with sodium hydroxide to produce compounds [C2]. Hydrazine hydrate reacted with compound [C2] to generate compound [C3]. Compound [C4] was synthesized from compound [C3] and maleic anhydride. A polymer [C5] is formed by the reaction of the compound [C4] with ammonium persulfate as an initiator. This polymer was then combined with nano: ZnNPs, AgNPs, SiNPs, or IONPs using a hotplate stirrer for 3 hours to produce nanocomposites [C6-C9]. FTIR, 1H-NMR, and Field Emission Scanning Electron Microscope (FESEM) were

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Aip Conference Proceedings
Study optoelectronic properties for polymer composite thick film
...Show More Authors

View Publication
Scopus (9)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Materials Science Forum
Thermophysical Properties for ZnO-Water Nanofluid: Experimental Study
...Show More Authors

This paper presents the thermophysical properties of zinc oxide nanofluid that have been measured for experimental investigation. The main contribution of this study is to define the heat transfer characteristics of nanofluids. The measuring of these properties was carried out within a range of temperatures from 25 °C to 45 °C, volume fraction from 1 to 2 %, and the average nanoparticle diameter size is 25 nm, and the base fluid is water. The thermophysical properties, including viscosity and thermal conductivity, were measured by using Brookfield rotational Viscometer and Thermal Properties Analyzer, respectively. The result indicates that the thermophysical properties of zinc oxide nanofluid increasing with nanoparticle volume f

... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Adsorption Study for Chromium (VI) on Iraqi Bentonite
...Show More Authors

The subject of this research involves studying adsorption to remove hexavalent chromium Cr(VI) from aqueous solutions. Adsorption process on bentonite clay as adsorbent was used in the Cr(VI) concentration range (10-100) ppm at different temperatures (298, 303, 308 and 313)K, for different periods of time. The adsorption isotherms were obtained by obeying Langmuir and Freundlich adsorption isotherm with R2 (0.9921-0.9060) and (0.994-0.9998), respectively. The thermodynamic parameters were calculated by using the adsorption process at four different temperatures the values of ?H, ?G and ?S was [(+6.582 ? +6.547) kJ.mol-1, (-284.560 ? -343.070) kJ.mol-1 and (+0.977 ? +1.117) kJ.K-1.mol-1] respectively. This data indicates the spontaneous sorp

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed May 12 2010
Journal Name
Tikrit Journal Of Pure Science
Synthesis and Characterizationof Mn(II),Co(II),Ni(II) , Cu(II) Complexes with 2- ( 4- Antipyrene azo )-tyrosine Ligand.
...Show More Authors

Coupling reaction of ( 4-amino antipyrene) with the (L- tyrosine ) gave the new azo ligand 2- ( 4- Antipyrene azo ) - tyrosine .Treatment of this ligand with metal ions (Mn(II) ,Co(II), Ni(II), and Cu(II) )in ethanolic medium in (1:2) (M:L) ratio yield a series of a neutral complexes of the general formula [M(L)2] . The prepared complexes were characterized using flame atomic absorption , FT.IR , UV-Vis spectroscopic and elemental microanalysis (C.H.N) as well as magnetic susceptibility and conductivity measurement

Publication Date
Mon Mar 23 2020
Journal Name
Journal Of Engineering
Post-buckling Analysis of Cold-form Steel Column
...Show More Authors

For the time being, the cold-formed sections are widely used due to their simple manufacturing and construction processes. To be feasible, the strength of cold-formed columns should be determined based on their post-buckling behavior. Post-buckling relations are cumbersome and need design aids similar to those of American Iron and Steel Institute (AISI) to be applicable. These design aids have been developed to sections and materials other than those available in the local market. Therefore, this paper tries to develop a general finite element model to simulate the postbuckling behavior of cold-formed steel columns. Shell element has been used to discretize the web, flanges, and lips of the column. A linear bucking analy

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Application Tools Lean Six Sigma Definition and measurement phases in new product development. In the Electrical Industries State Company. case Study.
...Show More Authors

methodology six sigma Help  to reduce defects by solving problems effectively, and works Lean to reduce losses through the flow of the manufacturing process and when integrating these two methodologies (Lean and six sigma), the methodology of Lean six sigma will form the entrance to the organizers of the optimization process and increase the quality and reduce lead times and costs . by focusing on the needs of the customer. this process uses statistical tools and techniques to analyze and improve processes.

 We have conducted this research in the General Company for Electrical Industries and adopted its product (machine cooling water three taps) as a sample for research. In order to determine t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Performance evaluation of vocational and administrative institutions in the media using the bench-marking of new media: analytical study in the Journal of time
...Show More Authors

Provides the style of benchmarking the best possible use whenevaluating the performance and evaluation, as well as improved performance,due to its consistency with the principles of good evaluation of theperformance, an extension of the completion of several functions of the timeand cost less, thereby increasing the efficiency of the management of theinstitutions, especially institutions, the media, as it became public the future ofthe message sender to the same time Zaorosaúl new media is challenging thetraditional media of what distinguishes this new interactive media and mass ledto this transition . However, the media Aljdidhoosaúl traditional mediacontinue to coexist and reinforce each Menhmaalakhr, for his wealth offreedom of opin

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Sand Modified with Nanoparticles of Calcium, Aluminum, and CTAB in the Form of Layered Double Hydroxide for Removing of Amoxicillin from Groundwater
...Show More Authors

The addition of new reactive sites on the surface area of the inert sand, which are represented by layered double hydroxide nanoparticles, is the primary goal of this work, which aims to transform the sand into a reactive material. Cetyltrimethylammonium bromide (CTAB) surfactant is used in the reaction of calcium extracted from solid waste-chicken eggshells with aluminum prepared from the cheapest coagulant-alum. By separating amoxicillin from wastewater, the performance of coated sand named as "sand coated with (Ca/Al-CTAB)-LDH" was evaluated. Measurements demonstrated that pH of 12 from 8, 9, 10, 11, and 12, CTAB dosage of 0.05 g from 0, 0.03, 0.05, and 0.1 g, ratio of Ca/Al of 2 from 1, 2, 3, and 4, and mass of sand of 1 g/50 mL from

... Show More
View Publication Preview PDF
Crossref