Traumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at least one indication to fix their fractured humerus, then all patients had evaluated with high-resolution ultrasound(7 Mhz) to assess the radial nerve by the same radiologist with three weeks of injury. Then all the patients have been treated with open reduction and internal fixation with an exploration of the radial nerve and the results were compared. The use of high-resolution ultrasound shows a low sensitivity and specificity (66.6% and 63.6% respectively) with low overall accuracy (64%). Our conclusion is the high-resolution ultrasound cannot be used as a diagnostic test for radial nerve injury associated with closed humeral shaft fracture, but still can show some traumatic pathology which may benefit from early surgical exploration.
The rubber ropes exercises affected muscle groups, which in turn affects the corners of the conditions of the body before and over the barrier where affected the time passed. To change the angle of the approaching and payment impact on passing each times the barrier 1-5. That passed over the barrier 1and gate 5 impacts on the nature of the achievement, where time has become less. Find the values of cruise missiles and other phases and stages of pitch angle other categories which it enshrines stood as compelling rejection men's 110m hurdles. Find the value of the instant messaging distances between different barriers and stages. Studies by adding rubber sling barriers race categories, measurement of kinematic variables. Emphasis on the devel
... Show MoreBackground: Periodontitis (PD) is well-known chronic disease affecting the periodontal ligament and alveolar bone, Osteoarthritis (OA) is a chronic joint disease with compound reasons characterized by synovial inflammation, subchondral bone remodeling, also the formation of osteophytes, that cause cartilage degradation. Chronic periodontitis and osteoarthritis are considered widely prevalent diseases and related to tissue destruction due to chronic inflammation in general health and oral health. The aim of this study is todetermine the association of chronic periodontitis and osteoarthritits in patients by analysing tumor necrosis factor alpha TNFα and high sensitive c-reactive protein (hsCRP) in the serum. Materials and Method: A tot
... Show MoreThe tetradentate N2O2 Schiff base ligand, which is produced via the condensation reaction of 2-hydroxynaphthaldehyde with phthalohydrazide, is prepared in this work with a fair yield. The prepared ligand was characterized using a microanalysis technique (C.H.N), UV-vis, FTIR, 1H-,13C-NMR, mass spectrometry, and thermal gravimetric analysis (TGA). New complexes were synthesized by a reaction between ligand (N'1E,N'2Z)-N'1,N'2-bis((1-hydroxynaphthalen-2yl)methylene)phthalohydrazide and metal chloride of Co+2, Ni+2, and Zn+2 ions in absolute ethanol. The present complexes are also characterized by techniques such as C.H.N, UV-vis, FTIR, TGA, molar conductivity, atomic absorption, and magnetic moment measurements. The in vitro antimicro
... Show Moreتم في هذه الدراسة ، تزيين رقائق أكسيد الجرافين (GO) بجسيمات كوبلتيت النيكل النانوية NiCo2O4(NC) عن طريق الترسيب في الموقع ، وتم استخدام المتراكب المحضر (NC: GO) كسطح ماز لإزالة صبغة الميثيل الخضراء ( MG) من المحاليل المائية. تم التحقق من التغطية الناجحة لأوكسيد الجرافين بجزيئات كوبلتيت النيكل النانوية (NC) باستخدام دراسات FT-IR وحيود الأشعة السينية (XRD). كانت أحجام الجسيم
... Show MoreKE Sharquie, AA Noaimi, MM Al-Salih, Saudi Medical Journal, 2008 - Cited by 56